Prevalence and natural course of pseudotumours after small-head metal-on-metal total hip arthroplasty

2019 ◽  
Vol 101-B (3) ◽  
pp. 317-324 ◽  
Author(s):  
J-K. Moon ◽  
Y. Kim ◽  
K-T. Hwang ◽  
J-H. Yang ◽  
J-A. Ryu ◽  
...  

Aims The present study investigated the five-year interval changes in pseudotumours and measured serum metal ions at long-term follow-up of a previous report of 28 mm diameter metal-on-metal (MoM) total hip arthroplasty (THA). Patients and Methods A total of 72 patients (mean age 46.6 years (37 to 55); 43 men, 29 women; 91 hips) who underwent cementless primary MoM THA with a 28 mm modular head were included. The mean follow-up duration was 20.3 years (18 to 24). All patients had CT scans at a mean 15.1 years (13 to 19) after the index operation and subsequent follow-up at a mean of 20.2 years (18 to 24). Pseudotumour volume, type of mass, and new-onset pseudotumours were evaluated using CT scanning. Clinical outcomes were assessed by Harris Hip Score (HHS) and the presence of groin pain. Serum metal ion (cobalt (Co) and chromium (Cr)) levels were measured at the latest follow-up. Results At final follow-up, pseudotumours were observed in 26/91 hips (28.6%). There was an increase in volume of the pseudotumour in four hips (15.4%), no change in volume in 21 hips (80.8%), and a decrease in volume in one hip (3.8%). There were no new-onset pseudotumours. There was no significant difference in HHS between patients with and without pseudotumours. At final follow-up, mean serum Co ion levels and median Co:Cr ratios were significantly greater in patients with pseudotumours, but the serum Cr ion levels were not significantly different. Conclusion At a mean 20 years of follow-up, pseudotumours were observed in 26/91 hips (28.6%) with no new-onset pseudotumours during subsequent follow-up. Most pseudotumours in small-head MoM THA were static in volume and asymptomatic with normal serum metal ion levels. Cite this article: Bone Joint J 2019;101-B:317–324.

2021 ◽  
Vol 9 ◽  
pp. 205031212110147
Author(s):  
Nobuhiko Sumiyoshi ◽  
Kazuhiro Oinuma ◽  
Yoko Miura

Background: Adverse reactions to metal debris are significant complications after metal-on-metal total hip arthroplasty. Recently, late appearances of adverse reactions to metal debris and subsequent need for reoperations have been reported with small-diameter head metal-on-metal devices. We retrospectively investigated mid-term clinical outcomes of small-head metal-on-metal total hip arthroplasty. Methods: We reviewed 159 hips in 139 patients who had a small-head metal-on-metal total hip arthroplasty (M2a Taper; Biomet, Warsaw, IN) with a minimum 5-year follow-up and documented postoperative complications. Results: Focal osteolysis in either the femur or acetabulum was observed in 12 hips (7.5%, 44 months after surgery on average), with pseudotumor observed in 8 hips (5%, 120 months after surgery on average). Four hips (2.5%) had dislocations (84 months after surgery on average) and six hips (3.8%, 122 months after surgery on average) underwent reoperation. Conclusion: Small-head metal-on-metal total hip arthroplasty is associated with a high degree of complications at mid-term follow-up period. Considering this, we discourage the use of metal-on-metal total hip arthroplasty regardless of head size.


Joints ◽  
2020 ◽  
Author(s):  
Christian Carulli ◽  
Giacomo Sani ◽  
Fabrizio Matassi ◽  
Roberto Civinini ◽  
Massimo Innocenti

Abstract Purrpose Metal-on-metal (MoM) total hip arthroplasty (THA) has been a subject of recent discussion and concern due to the early failures caused by local and systemic adverse reactions related to specific designs. The aim of this study is to analyze the outcomes and survival rates of a single brand of MoM implants implanted in a consecutive series of patients at a single institution. Methods Between 2007 and 2012, 116 (118 hips) patients were evaluated at a mean follow-up of 6.6 years after primary THA. The diagnosis leading to surgery was osteoarthritis (80 patients) and proximal femoral fracture (36 patients). A single design of THA was implanted. All patients were evaluated before surgery and postoperatively at 1, 3, 6, and 12 months by clinical scores and radiographic studies. The data analysis was made using Student's t-test. Results The minimum follow-up was of 4 years, with a mean follow-up of 6.6 years. Two aseptic loosenings of the acetabular component were recorded (one per group), which were not associated with local or systemic complications related to metal ion release. Both were revised by an isolated acetabular cup substitution with metal-on-polyethylene couplings. Nonprogressive radiolucency lines < 2 mm in zone 2 were observed in other six patients around the acetabular component without clinical manifestation (four in the arthritis group and two in the fracture group). Postoperative Harris Hip Score and SF-36 (36-Item Short Form Survey) score improved in both groups. Conclusion Despite several MoM implants showing early complications and failures, a specific MoM design may be associated with good clinical results at a mid- to long-term follow-up. Level of Evidence This is a therapeutic case series, Level 4 study.


2018 ◽  
Vol 29 (1) ◽  
pp. 65-71 ◽  
Author(s):  
Yoshitoshi Higuchi ◽  
Taisuke Seki ◽  
Yukiharu Hasegawa ◽  
Yasuhiko Takegami ◽  
Daigo Morita ◽  
...  

Introduction: This study aimed to compare the clinical and radiographic results of 28-mm ceramic-on-ceramic (CoC) total hip arthroplasty (THA) to those of 32-mm CoC during a 5- to 15-year follow-up period. Methods: 107 joints (95 women and 6 men) underwent 28-mm CoC, and 60 (49 women and 7 men) underwent 32-mm CoC. The average patient age at the time of surgery was 56.1 and 55.7 years in the 28-mm and 32-mm CoC groups, respectively. Clinical and radiologic measurements of all patients were analysed. Results: The mean preoperative Harris hip score (HHS) was similar in the 2 groups (28-mm, 58.9; and 32-mm, 58.5). However, at final follow-up, the mean HHS of the 32-mm CoC (91.8) was significantly better than that of the 28-mm CoC (88.2) ( p = 0.003), as were the ranges of motion (ROM) for flexion (98.3 ± 13.5° vs. 87.3 ± 19.3°, p < 0.001) and abduction (27.8 ± 14.9° vs. 22.1 ± 19.3°, p = 0.007). The mean wear rate was 0.0044 mm/year for the 28-mm CoC and 0.0044 mm/year for the 32-mm CoC. No ceramic fractures were found in the 2 groups. One joint in the 28-mm CoC (0.9%) required revision owing to progressive osteolysis. Kaplan-Meier survival at 10 years, with implant loosening or revision THA as the endpoint, was 98.3% for 28-mm CoC and 100% for 32-mm CoC ( p = 0.465). Conclusion: There was no significant difference in ceramic-related complications between the 2 groups. Our study demonstrated that the 32-mm and 28-mm CoC are safe and are associated with good clinical outcomes.


2017 ◽  
Vol 2017 ◽  
pp. 1-7
Author(s):  
Chih-Chien Hu ◽  
Tsan-Wen Huang ◽  
Shih-Jie Lin ◽  
Po-Chun Lin ◽  
Feng-Chih Kuo ◽  
...  

Large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA) has lost popularity because of metal allergy or ALTRs (adverse local tissue reactions) in the past decade. Whether the surgical approach may influence the survival of LDH-MoM-THA has not been reported. From 2006 to 2009, we performed 96 LDH-MoM-THAs on 80 patients using an in situ head-neck assembly technique through a modified Watson-Jones approach. With a mean follow-up of 8.4 years (range, 6.3–10.1 years), the implant survival rate was 100%. All patients were satisfied with the results and the Harris Hip Score improved from 52 points to 98 points. No ALTRs were found, but 17.7% of the 96 hips (17 adverse events) experienced adverse events related to the cup, including 5 cases of outlier cup malposition, 11 cases of inadequate cup seating, and 1 acetabular fracture. The tissue tension that was improved by a muscle-sparing approach might lessen the chance of microseparation or edge-loading that is taken as the major risk for early implant failure. Further investigation of whether these LDH-MoM-THAs would fail or not would require a longer follow-up or even retrieval analysis in the future.


2015 ◽  
Vol 45 (1) ◽  
pp. 115-125 ◽  
Author(s):  
Mette Holm Hjorth ◽  
Maiken Stilling ◽  
Kjeld Soballe ◽  
Lars Hans Bolvig ◽  
Jacob Pontoppidan Thyssen ◽  
...  

2020 ◽  
Author(s):  
Wenli Chen ◽  
Mao Shuai ◽  
Jinluan Lin ◽  
Baomin Chen ◽  
Mingdong Zhao ◽  
...  

Abstract Background A high rate of complications due to metal-on-metal (MoM) revisions has been relatively commonly documented. The purpose of this retrospective study was to compare the long-term outcomes of patients who had undergone uncemented or cemented total hip arthroplasty (THA) revision for prior primary MoM THA failure.Methods Data from 234 patients (234 hips) who underwent uncemented or cemented THA (UTHA or CTHA) for prior primary MoM THA failure during 2007 - 2018 were retrospectively analysed. Follow-up occurred 3 months, 6 months, 1 year, 2 years, and then every 1 year after conversion. The mean follow-up time was 84.15 months (range, 67 - 101 months). The primary endpoint was the modified Harris Hip Score (HHS). The secondary endpoint was the major orthopaedic complication rate.Results The HHS demonstrated statistically greater differences in the CTHA group than in the UTHA group 12 months after conversion. From the 12th month after conversion to the final follow-up, CTHA yielded better functional outcomes than UTHA. There were significant differences in the rates of re-revision, aseptic loosening, and periprosthetic fracture between the groups (10.3% for UTHA vs 2.5% for CTHA, p = 0.015; 16.3% for UTHA vs 5.9% for CTHA, p = 0.011; and 12.0% for UTHA vs 4.2% for CTHA, p = 0.045, respectively).Conclusion In the setting of revision for primary MoM THA failure, we found definite evidence of the superiority of CTHA over UTHA in terms of improving functional outcomes and decreasing the major orthopaedic complication rate.


Diagnostics ◽  
2020 ◽  
Vol 10 (11) ◽  
pp. 941
Author(s):  
Assunta Pozzuoli ◽  
Antonio Berizzi ◽  
Alberto Crimì ◽  
Elisa Belluzzi ◽  
Anna Chiara Frigo ◽  
...  

Total hip arthroplasty (THA) with metal-on-metal (MoM) bearings have shown problems of biocompatibility linked to metal ion release at the local level causing an adverse reaction to metal debris (ARMD) and at a systemic level. The aim of this study was to evaluate clinical and radiological outcomes, and metal ion concentrations in the blood and urine of patients who underwent THA with the LIMA Met-Met hip system. Patients with ceramic-on-ceramic (CoC) bearings were included as a control group. In this study, 68 patients were enrolled: 34 with MoM THAs and 34 with CoC THAs. Patients were evaluated clinically (Harris Hip Score, SF-36) and radiologically at a median of 7.4 years after surgery. Whole blood and urinary cobalt and chromium levels were also assessed. Both types of implants were comparable in terms of clinical and functional results. Ion levels were significantly higher in the MoM group compared with CoC group 7 years after surgery. No correlations were found between metal ion levels and patient demographics, functional and radiological outcomes, and prosthesis features. Patient monitoring is thus advised to establish if prosthesis revision is necessary, especially in the case of MoM THA.


10.29007/455b ◽  
2018 ◽  
Author(s):  
Itay Perets ◽  
John Walsh ◽  
Brian Mu ◽  
Yosif Mansor ◽  
Leslie Yuen ◽  
...  

Recent advances have made robotic assistance a viable option in total hip arthroplasty (THA). However, the clinical outcomes of this procedure relative to THA without robotic assistance have yet to be reported. This study presents short-term outcomes of robotically assisted THA compared to a pair-matched control group of patients that underwent THA without robotic assistance.Data were prospectively collected on all THAs performed from July 2011 to January 2015. Patients were included if they underwent primary THA treating idiopathic osteoarthritis and were eligible for minimum two-year follow-up. Outcomes were measured using Harris Hip Score (HHS), the Forgotten Joint Score (FJS-12), pain on a visual analog scale (VAS), and satisfaction from 0-10. Patients that underwent THA with robotic assistance were matched 1:1 with THA patients without robotic assistance for age, sex, BMI, and approach.There were 85 patients in each study group. There were no significant differences in the demographic factors matched for. Both HHS and FJS-12 were significantly higher in the robotic assistance group at minimum two-year follow-up. VAS was lower in the robotic assistance group, but this was not statistically significant (p = 0.12). There was a not a significant difference in patient satisfaction. There was no significant difference in the rate of postoperative complications or subsequent revisions between groups.Robotically assisted THA is safe and may lead to superior short-term outcomes compared to THA without robotic assistance.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Peter Nyby Hersnaes ◽  
Kirill Gromov ◽  
Kristian Stahl Otte ◽  
Peter Henrik Gebuhr ◽  
Anders Troelsen

Abstract Background The metal-on-metal large-diameter-head (MoM-LDH) hip replacements increased in popularity during the start of the twenty-first century. Subsequently reports raised concerns regarding adverse reactions due to elevated chromium (Cr) and cobalt (Co) concentrations as well as high rates of other complications and revisions. The purpose was to compare Harris Hip Score and SF-36 at 5-years follow up following MoM-LDH total hip arthroplasty (MoM-LDH-THA) or MoM hip resurfacing (MoM-HR). Methods The study was conducted between November 2006 to January 2012 in a tertiary health care center in Denmark. Patients with primary or secondary osteoarthritis were randomly assigned to receive a Magnum (MoM-LDH-THA) or a Recap (MoM-HR) prosthesis. Randomization was computer generated and allocation was concealed in an opaque envelope. Neither patients nor care provider were blinded. Primary outcome was Harris Hip Score at 5-years follow up. Results Seventy-five were included and allocated to the MoM-LDH-THA (n = 39) and MoM-HR (n = 36) group. The study was prematurely stopped due to numerous reports of adverse events in patients with MoM hip replacements. Thirty-three in the MoM-LDH-THA and 25 in the MoM-HR group were available for primary outcome analysis. Median Harris Hip Score was 100 (IQR: 98–100) for MoM-LDH-THA and 100 (IQR: 93–100) for MoM-HR (p = 0.486). SF-36 score was high in both groups with no significant difference between groups. Conclusion Harris Hip Score and SF-36 score was excellent in both groups with no significant difference at 5-years follow up. Our findings suggest that there is no clinical important difference between the two prostheses implanted 5 years after implantation. Trial registration ClinicalTrials.gov, NCT04585022, Registered 23 September 2020 – Retrospectively registered. This study was not prospectively registered in a clinical trial database since it was not an entirely implemented standard procedure in the international orthopedic society when the study was planned.


2012 ◽  
Vol 36 (9) ◽  
pp. 1807-1812 ◽  
Author(s):  
Mitchell Bernstein ◽  
Nicholas M. Desy ◽  
Alain Petit ◽  
David J. Zukor ◽  
Olga L. Huk ◽  
...  

Sign in / Sign up