Evaluation of a 3D-printed total knee arthroplasty using radiostereometric analysis

2019 ◽  
Vol 101-B (7_Supple_C) ◽  
pp. 40-47 ◽  
Author(s):  
S. Sporer ◽  
L. MacLean ◽  
A. Burger ◽  
M. Moric

AimsOur intention was to investigate if the highly porous biological fixation surfaces of a new 3D-printed total knee arthroplasty (TKA) achieved adequate fixation of the tibial and patellar components to the underlying bone.Patients and MethodsA total of 29 patients undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate and metal-backed patella. Patient-reported outcomes measures were recorded and implant migration was assessed using radiostereometric analysis.ResultsPatient function significantly improved by three months postoperatively (p < 0.001). Mean difference in maximum total point motion between 12 and 24 months was 0.021 mm (-0.265 to 0.572) for the tibial implant and 0.089 mm (-0.337 to 0.758) for the patellar implant. The rate of tibial and patellar migration was largest over the first six postoperative weeks, with no changes in mean tibia migration occurring after six months, and no changes in mean patellar migration occurring after six weeks. One patellar component showed a rapid rate of migration between 12 and 24 months.ConclusionBiological fixation appears to occur reliably on the highly porous implant surface of the tibial baseplate and metal-backed patellar component. Rapid migration after 12 months was measured for one patellar component. Further investigation is required to assess the long-term stability of the 3D-printed components and to determine if the high-migrating components achieve fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):40–47

2020 ◽  
Vol 102-B (8) ◽  
pp. 1016-1024 ◽  
Author(s):  
Shaho Hasan ◽  
Koen T. van Hamersveld ◽  
Perla J. Marang-van de Mheen ◽  
Bart L. Kaptein ◽  
Rob G. H. H. Nelissen ◽  
...  

Aims Although bone cement is the primary mode of fixation in total knee arthroplasty (TKA), cementless fixation is gaining interest as it has the potential of achieving lasting biological fixation. By 3D printing an implant, highly porous structures can be manufactured, promoting osseointegration into the implant to prevent aseptic loosening. This study compares the migration of cementless, 3D-printed TKA to cemented TKA of a similar design up to two years of follow-up using radiostereometric analysis (RSA) known for its ability to predict aseptic loosening. Methods A total of 72 patients were randomized to either cementless 3D-printed or a cemented cruciate retaining TKA. RSA and clinical scores were evaluated at baseline and postoperatively at three, 12, and 24 months. A mixed model was used to analyze the repeated measurements. Results The mean maximum total point motion (MTPM) at three, 12, and 24 months was 0.33 mm (95% confidence interval (CI) 0.25 to 0.42), 0.42 mm (95% CI 0.33 to 0.51), and 0.47 mm (95% CI 0.38 to 0.57) respectively in the cemented group, versus 0.52 mm (95% CI 0.43 to 0.63), 0.62 mm (95% CI 0.52 to 0.73), and 0.64 mm (95% CI 0.53 to 0.75) in the cementless group (p = 0.003). However, using three months as baseline, no difference in mean migration between groups was found (p = 0.497). Three implants in the cemented group showed a > 0.2 mm increase in MTPM between one and two years of follow-up. In the cementless group, one implant was revised due to pain and progressive migration, and one patient had a liner-exchange due to a deep infection. Conclusion The cementless TKA migrated more than the cemented TKA in the first two-year period. This difference was mainly due to a higher initial migration of the cementless TKA in the first three postoperative months after which stabilization was observed in all but one malaligned and early revised TKA. Whether the biological fixation of the cementless implants will result in an increased long-term survivorship requires a longer follow-up. Cite this article: Bone Joint J 2020;102-B(8):1016–1024.


2020 ◽  
Author(s):  
Yang Li ◽  
Xinguang Wang ◽  
Hua Tian

Abstract Background: The reconstruction of massive bone defects is one of the main challenges in revision total knee arthroplasty (RTKA). Although several methods are available, each of them has its prominent shortcomings. The purpose of this study is to review the clinical outcomes of RTKA with massive proximal tibial bone defects using patient-customized three-dimensional (3D)-printed highly porous metaphyseal cones.Methods: We retrospectively reviewed seven RTKAs with Anderson Orthopaedic Research Institute (AORI) type III tibial defects using patient-customized 3D-printed highly porous metaphyseal cones, which have been performed at a single institution between 2016 and 2018. Results: The mean age at diagnosis of the patients was 68 years old (61-77). The mean length of follow-up was 25.3 months (19-36). At the latest follow-up, no aseptic loosening or prosthetic joint infection has been determined. The mean HSS increased from 49 (39-63) to 78 (70-83) (P<0.01); the mean WOMAC increased from 59 (46-73) to 26 (12-38) (P<0.01). All patients obtained the range of motion and mechanical alignment improvement postoperatively.Conclusion: The patient-customized 3D-printed metaphyseal cone could be a promising technique in addressing severe tibial defects in RTKA. Our study shows encouraging short-term clinical and radiological outcomes with no aseptic loosening, periprosthetic infection, or fracture. Nevertheless, further follow-up and the expansion of sample size are needed to demonstrate the advantage of this innovative technique fully.


2021 ◽  
Vol 103-B (6 Supple A) ◽  
pp. 32-37
Author(s):  
Santiago Restrepo ◽  
Eric B. Smith ◽  
William James Hozack

Aims Cementless total knee arthroplasty (TKA) offers the potential for strong biological fixation compared with cemented TKA where fixation is achieved by the mechanical integration of the cement. Few mid-term results are available for newer cementless TKA designs, which have used additive manufacturing (3D printing). The aim of this study was to present mid-term clinical outcomes and implant survivorship of the cementless Stryker Triathlon Tritanium TKA. Methods This was a single institution registry review of prospectively gathered data from 341 cementless Triathlon Tritanium TKAs at four to 6.8 years follow-up. Outcomes were determined by comparing pre- and postoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS JR) scores, and pre- and postoperative 12-item Veterans RAND/Short Form Health Survey (VR/SF-12) scores. Aseptic loosening and revision for any reason were the endpoints which were used to determine survivorship at five years. Results At mid-term follow-up, the mean KOOS JR score improved significantly from 33.14 (0 t0 85, standard deviation (SD) 21.88) preoperatively to 84.12 (15.94 to 100, SD 20.51) postoperatively (p < 0.001), the mean VR/SF-12 scores improved significantly from physical health (PH), 31.21 (SD 5.32; 23.99 to 56.77) preoperatively to 42.62 (SD 10.72; 19.38 to 56.82) postoperatively (p < 0.001) and the mental health (MH), 38.15 (SD 8.17; 19.06 to 60.75) preoperatively to 55.09 (SD 9.64; 19.06 to 66.98) postoperatively (p < 0.001). A total of 11 revisions were undertaken, with an overall revision rate of 2.94%, including five for periprosthetic joint infection (1.34%), three for loosening (0.80%), two for instability (0.53%), and one for pain (0.27%). The overall survivorship was 97.06% and survivorship for aseptic loosening as the endpoint was 98.40%, with a 99.5% survivorship of the 3D-printed tibial component. Conclusion This 3D-printed cementless total knee system shows excellent survivorship at mid-term follow-up. This design and the ability to obtain cementless fixation offers promise for excellent long-term durability. Cite this article: Bone Joint J 2021;103-B(6 Supple A):32–37.


2020 ◽  
Author(s):  
Yang Li ◽  
Xinguang Wang ◽  
Hua Tian

Abstract Background The reconstruction of massive bone defects is one of the main challenges in revision total knee arthroplasty (RTKA). Although several methods are available, each of them has its prominent shortcomings. The purpose of this study is to review the clinical outcomes of RTKA with massive proximal tibial bone defects using patient-customized three-dimensional (3D)-printed highly porous metaphyseal cones. Methods We retrospectively reviewed seven RTKAs with Anderson Orthopaedic Research Institute (AORI) type III tibial defects using patient-customized 3D-printed highly porous metaphyseal cones, which have been performed at a single institution between 2016 and 2018. The mean length of follow-up was 25.3 months (19–36). Results The mean age at diagnosis of the patients was 68 years old (61–77). At the latest follow-up, no aseptic loosening or prosthetic joint infection has been determined. The mean HSS increased from 49 (39–63) to 78 (70–83) (P < 0.01); the mean WOMAC increased from 59 (46–73) to 26 (12–38) (P < 0.01). All patients obtained the range of motion and mechanical alignment improvement postoperatively. Conclusion The patient-customized 3D-printed metaphyseal cone could be a promising technique in addressing severe tibial defects in RTKA. Our study shows encouraging short-term clinical and radiological outcomes with no aseptic loosening, periprosthetic infection, or fracture. Nevertheless, further follow-up and the expansion of sample size are needed to demonstrate the advantage of this innovative technique fully.


Author(s):  
Antonio Klasan ◽  
Sven Edward Putnis ◽  
Wai Weng Yeo ◽  
Darli Myat ◽  
Brett Andrew Fritsch ◽  
...  

AbstractDespite multiple studies, there remains a debate on the safety of bilateral total knee arthroplasty (BTKA) in the average age patient, with a paucity of data on the outcome of BTKA in an elderly population. This study included 89 patients aged 80 years and older undergoing sequential BTKA over 14 years were identified in a prospectively collected database. Two matched comparison groups were created: patients under 80 undergoing sequential BTKA and patients over 80 undergoing unilateral TKA (UTKA). An analysis of complications, mortality, revision, and patient-reported outcome measures was performed. Mean age of the elderly cohorts was similar: 82.6 for BTKA and 82.9 for UTKA. The average age BTKA cohort had a mean age of 69.1. Complication rates were higher in bilateral cohorts, more so in the elderly BTKA cohort. Pulmonary embolism (PE) was observed in bilateral cohorts only. In these patients, history of PE and ischemic heart disease was a strong predictive factor for developing a major complication. There was no difference in revision rates and infection rates between the three cohorts, and no difference in patient survivorship between the two elderly cohorts. Through the combination of low revision and high survivorship rates and comparable clinical outcomes, this article demonstrates that simultaneous BTKA is an appropriate option to consider for an elderly patient, with proper patient selection and perioperative management. The demonstrated risk groups show that emphasis on patient selection should be focused on medical history rather than chronological age.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Jake von Hintze ◽  
Mika Niemeläinen ◽  
Harri Sintonen ◽  
Jyrki Nieminen ◽  
Antti Eskelinen

Abstract Background The purpose of this study was to determine the mid-term clinical, radiographic and health-related quality of life (HRQoL) outcomes and define the survival rate in patients who had undergone revision total knee arthroplasty (TKA) using the single rotating hinged knee (RHK) design. Methods Between January 2004 and December 2013, 125 revision TKAs were performed at our institution using the single RHK implant. We conducted both a retrospective analysis of prospectively collected outcome data of these patients and a prospective follow-up study of all 39 living patients (41 knees). The follow-up phase included an optional extra follow-up visit, PROM questionnaires, and plain radiographs. Results The ten-year Kaplan-Meier survival rate of the revision RHK knees was 81.7% (95% CI 71.9–91.6%) with re-revision for any reason as the endpoint. Overall, 15 knees (12% of the total) underwent re-revision surgery during the follow-up. The median follow-up was 6.2 years (range, 0–12.7 years) post-operatively for the baseline group. One mechanical hinge mechanism-related failure occurred without any history of trauma or infection. At the time of the final follow-up, the majority of patients evinced a fairly good clinical outcome measured with patient-reported outcome measures and none of the components were radiographically loose. Conclusion We found that in patients undergoing complex revision TKA, fairly good functional outcome and quality of life can be achieved using an RHK implant. Further, it seems that in this type of patient cohort, revision TKA using an RHK implant relieves pain more than it improves ability to function. The NexGen® RHK design can be regarded as a suitable option in complex revision TKA.


Author(s):  
Eitan Ingall ◽  
Christian Klemt ◽  
Christopher M. Melnic ◽  
Wayne B. Cohen-Levy ◽  
Venkatsaiakhil Tirumala ◽  
...  

AbstractThis is a retrospective study. Prior studies have characterized the deleterious effects of narcotic use in patients undergoing primary total knee arthroplasty (TKA). While there is an increasing revision arthroplasty burden, data on the effect of narcotic use in the revision surgery setting remain limited. Our aim was to characterize the effect of active narcotic use at the time of revision TKA on patient-reported outcome measures (PROMs). A total of 330 consecutive patients who underwent revision TKA and completed both pre- and postoperative PROMs was identified. Due to differences in baseline characteristics, 99 opioid users were matched to 198 nonusers using the nearest-neighbor propensity score matching. Pre- and postoperative knee disability and osteoarthritis outcome score physical function (KOOS-PS), patient reported outcomes measurement information system short form (PROMIS SF) physical, PROMIS SF mental, and physical SF 10A scores were evaluated. Opioid use was identified by the medication reconciliation on the day of surgery. Propensity score–matched opioid users had significantly lower preoperative PROMs than the nonuser for KOOS-PS (45.2 vs. 53.8, p < 0.01), PROMIS SF physical (37.2 vs. 42.5, p < 0.01), PROMIS SF mental (44.2 vs. 51.3, p < 0.01), and physical SF 10A (34.1 vs. 36.8, p < 0.01). Postoperatively, opioid-users demonstrated significantly lower scores across all PROMs: KOOS-PS (59.2 vs. 67.2, p < 0.001), PROMIS SF physical (43.2 vs. 52.4, p < 0.001), PROMIS SF mental (47.5 vs. 58.9, p < 0.001), and physical SF 10A (40.5 vs. 49.4, p < 0.001). Propensity score–matched opioid-users demonstrated a significantly smaller absolute increase in scores for PROMIS SF Physical (p = 0.03) and Physical SF 10A (p < 0.01), as well as an increased hospital length of stay (p = 0.04). Patients who are actively taking opioids at the time of revision TKA report significantly lower preoperative and postoperative outcome scores. These patients are more likely to have longer hospital stays. The apparent negative effect on patient reported outcomes after revision TKA provides clinically useful data for surgeons in engaging patients in a preoperative counseling regarding narcotic use prior to revision TKA to optimize outcomes.


Author(s):  
Cristina Dauder Gallego ◽  
Irene Blanca Moreno Fenoll ◽  
José Luis Patiño Contreras ◽  
Francisco Javier Moreno Coronas ◽  
María del Carmen Torrejón de la Cal ◽  
...  

Author(s):  
Junren Zhang ◽  
Wofhatwa Solomon Ndou ◽  
Nathan Ng ◽  
Paul Gaston ◽  
Philip M. Simpson ◽  
...  

A correction to this paper has been published: https://doi.org/10.1007/s00167-021-06522-x


Sign in / Sign up

Export Citation Format

Share Document