Radiolucent lines do not affect the longevity of highly cross-linked polyethylene cemented components in total hip arthroplasty

2021 ◽  
Vol 103-B (10) ◽  
pp. 1604-1610
Author(s):  
Yusuke Takaoka ◽  
Koji Goto ◽  
Jiro Tamura ◽  
Yaichiro Okuzu ◽  
Toshiyuki Kawai ◽  
...  

Aims We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. Conclusion The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604–1610.

2002 ◽  
Vol 10 (2) ◽  
pp. 165-169 ◽  
Author(s):  
DA Stanton ◽  
WJ Bruce ◽  
JA Goldberg ◽  
W Walsh

Purpose. To review cases of implantation of constraining acetabular components for unstable or recurrent dislocating total hip arthroplasty at the Department of Orthopaedics, Concord Hospital, Sydney. Methods. A retrospective analysis was performed on prospectively collected data of 13 consecutively enrolled patients. Results. From 1989 to 2000, 13 constraining acetabular components were implanted into 13 patients as a revision procedure. The surgical approach for the implantation of the constrained liner was posterolateral in 11 cases; a modified Hardinge approach was applied in 2 cases. The mean clinical follow-up duration was 43 months (range, 14–121 months) and the mean age at the time of surgery was 73 years (range, 52–84 years). No patients were lost to follow-up. Indications for using the constrained acetabular component were recurrent dislocation in revision hip replacements (n=8), and intra-operative instability (n=5). There were no episodes of dislocation of the constrained arthroplasty. In 7 cases, the constrained component was implanted into a previously well-fixed shell. Conclusion. We recommend the judicious use of the constrained component in cases of hip instability during or after total hip arthroplasty when other methods are not successful.


2021 ◽  
Vol 2 (1) ◽  
pp. 33-39
Author(s):  
Jeffrey R. McLaughlin ◽  
Kyla R. Lee ◽  
Mary Ann Johnson

Aims We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. Methods A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one. Results Two femoral components (3.2%) required revision. One stem was revised secondary to a periprosthetic fracture one year postoperatively and one was revised for late sepsis. No femoral component was revised for aseptic loosening. Six acetabular components had required revision, five for aseptic loosening. One additional acetabular component was revised for sepsis. Radiologically, all femoral components remained well fixed. One acetabular was judged loose by radiological criteria. The mean Harris Hip Score improved from 46 points (30 to 67) preoperatively to 89 points (78 to 100) at final follow-up. With revision for aseptic loosening as the endpoint, survival of the acetabular component was 95% (95% confidence interval (CI) 90 to 98) at 25 years. Femoral component survival was 100%. Conclusion The most significant finding of this report was the low prevalence of aseptic loosening and revision of the femoral component at a mean follow-up of 22 years. A second important finding was the survival of over 90% of the hemispheric threaded ring acetabular components. While these shells remain controversial, in this series they performed well. Cite this article: Bone Jt Open 2021;2(1):33–39.


1988 ◽  
Vol 29 (6) ◽  
pp. 746-748 ◽  
Author(s):  
A. Wykman ◽  
B. K. S. Sanjay ◽  
V. Söderlund ◽  
I. Goldie

Radiologic grading of non-cemented acetabular components in HP Garches total hip replacements was used to evaluate the relationship between a lack of supero-lateral cover of the acetabular component and clinical outcome. In 63 hips, three to five years after total hip arthroplasty, we observed that the acetabular component was partially uncovered in 56 per cent of cases. The fact that several components were partially uncovered did not influence the clinical outcome. Although the follow-up time is short the present study indicates that non-cemented HP Garches total hip arthroplasty is a technique which allows for stable fixation of the acetabular component.


2021 ◽  
pp. 112070002110434
Author(s):  
Libor Necas ◽  
Maros Hrubina ◽  
Marian Melisik ◽  
Juraj Cabala ◽  
Zoltan Cibula ◽  
...  

Background: Mid-term results (clinical and radiographic) of ultra-short anatomical cementless stem total hip arthroplasty (THA) in patients with osteonecrosis of the femoral head (ONFH) has not often been presented. The aim of this study is to evaluate THA using the Proxima stem in patients with ONFH in the mid-term. Methods: The study consists of 73 patients (97 THAs) with a Proxima stem implanted between 2006 and 2015. The mean age of patients was 47.4 years, with a mean follow-up 105.2 months. The clinical results include preoperative and postoperative Harris Hip Scores (HHSs). Radiological follow-up reports on stem migration, bony trabecular development and radiolucent lines. The complications and revisions were registered. Kaplan-Meier survival analysis was performed to determine the implant survival. Results: The average HHS improved significantly from 40.3 preoperatively to 98.0 at the final evaluation ( p  ˂ 0.0001). Stem migration (subsidence and “varisation”) was observed in 11 hips (in 9 of them up to 6th postoperative month without any further progression, in 2 with progressive migration and radiological loosening). Bony trabecular development was detected in modified Gruen zones (1,2,4,6,7 for Proxima stem): in zone 1 (0%), 2 (67.0%), 4 (64.9%), 6 (64.9%), 7 (0%). Radiolucent lines were observed in 1 cup and 6 stems (2 were loose, 4 with fibrous stable fixation). Complications were found in 5 hips (5.1%): squeezing hip once, repeated dislocation in 1, 1 early deep infection, and 2 loose stems. 2 hips (2.1%) were revised (dislocation, infection). The implant survival was 98.9% and 97.9% clinically and radiologically, respectively. Conclusions: Observations in the mid-term show that the clinical and radiological results of the Proxima stem in patients with ONFH are promising. The stem design preserves the proximal femoral bone stock. The bony trabecular appearance confirms physiological proximal femoral load transmission.


2018 ◽  
Vol 29 (2) ◽  
pp. 222-225
Author(s):  
William Stickney ◽  
Richard S Yoon ◽  
Jay N Patel ◽  
David S Klein ◽  
George J Haiduekwych ◽  
...  

Introduction: In the revision setting, intrapelvic acetabular components provide a unique set of challenges for the treating surgeon. Retrieval is complicated by complex anatomical relationships within the pelvis and historically, surgeons have used multiple approaches to safely retrieve the cup. Case presentation: We present the case of a 53-year-old female with intrapelvic migration of the acetabular components of her total hip arthroplasty. Patient was treated through a novel, single incision approach with utilisation of an anterior inferior iliac spine (AIIS) osteotomy. Results: An AIIS osteotomy allows for improved visualisation within the pelvis and safe retrieval through a single exposure without compromising the ability to perform definitive, revision reconstruction. At 1-year follow-up, the patient has had no complications related to infection or failure of the implants. Ambulation is performed with the aid of a cane in the community with mild, occasional pain.


2017 ◽  
Vol 2017 ◽  
pp. 1-7
Author(s):  
Shih-Jie Lin ◽  
Tsan-Wen Huang ◽  
Po-Chun Lin ◽  
Feng-Chih Kuo ◽  
Kuo-Ti Peng ◽  
...  

Long-term data and information indicating whether minimally invasive surgery (MIS) approaches are safe and effective with total hip arthroplasty (THA) are lacking. Between 2004 and 2006, 75 patients with alcohol-related osteonecrosis of the femoral head (ONFH) who underwent 75 THAs with the two-incision approach were studied. The medical records, radiographic parameters, and functional outcomes were collected prospectively. All data were compared with those for matched patients who underwent a modified Watson-Jones (WJ) approach. THA using the two-incision approach was associated with longer operation time, more blood loss, more lateral femoral cutaneous nerve injury, and more periprosthetic femoral fractures (p<0.05for all four) than the modified WJ approach. The Harris Hip Score (HHS) and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) increased significantly from the period preoperatively to 6 weeks postoperatively and thereafter up to the last follow-up in both groups. However, there were no significant differences in terms of radiographic parameters and functional outcomes between the two groups throughout the study period. Both the two-incision and the modified WJ approach provided satisfactory results and survival rates at a mean follow-up of 10.8 years. A prospective, randomized, large-scale cohort study is still warranted for evidence-based recommendations.


Joints ◽  
2020 ◽  
Author(s):  
Christian Carulli ◽  
Giacomo Sani ◽  
Fabrizio Matassi ◽  
Roberto Civinini ◽  
Massimo Innocenti

Abstract Purrpose Metal-on-metal (MoM) total hip arthroplasty (THA) has been a subject of recent discussion and concern due to the early failures caused by local and systemic adverse reactions related to specific designs. The aim of this study is to analyze the outcomes and survival rates of a single brand of MoM implants implanted in a consecutive series of patients at a single institution. Methods Between 2007 and 2012, 116 (118 hips) patients were evaluated at a mean follow-up of 6.6 years after primary THA. The diagnosis leading to surgery was osteoarthritis (80 patients) and proximal femoral fracture (36 patients). A single design of THA was implanted. All patients were evaluated before surgery and postoperatively at 1, 3, 6, and 12 months by clinical scores and radiographic studies. The data analysis was made using Student's t-test. Results The minimum follow-up was of 4 years, with a mean follow-up of 6.6 years. Two aseptic loosenings of the acetabular component were recorded (one per group), which were not associated with local or systemic complications related to metal ion release. Both were revised by an isolated acetabular cup substitution with metal-on-polyethylene couplings. Nonprogressive radiolucency lines < 2 mm in zone 2 were observed in other six patients around the acetabular component without clinical manifestation (four in the arthritis group and two in the fracture group). Postoperative Harris Hip Score and SF-36 (36-Item Short Form Survey) score improved in both groups. Conclusion Despite several MoM implants showing early complications and failures, a specific MoM design may be associated with good clinical results at a mid- to long-term follow-up. Level of Evidence This is a therapeutic case series, Level 4 study.


2018 ◽  
Vol 100-B (11) ◽  
pp. 1434-1441 ◽  
Author(s):  
W. G. Blakeney ◽  
Y. Beaulieu ◽  
B. Puliero ◽  
M. Lavigne ◽  
A. Roy ◽  
...  

Aims This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Patients and Methods Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up. Results There were four re-operations (1%) including one early revision for insufficient primary fixation (0.4%). No hip dislocation was reported. The mean University of California, Los Angeles (UCLA) activity score, 12-Item Short-Form Health Survey (SF-12) Mental Component Summary (MCS) score, SF-12 Physical Component Summary (PCS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Forgotten Joint Score (FJS) were 6.6 (2 to 10), 52.8 (25.5 to 65.7), 53.0 (27.2 to 66.5), 7.7 (0 to 63), and 88.5 (23 to 100), respectively. No signs of loosening or osteolysis were observed on radiological review. The incidence of squeaking was 23% (n = 51/225). Squeaking was significantly associated with larger head diameter (p < 0.001), younger age (p < 0.001), higher SF-12 PCS (p < 0.001), and UCLA scores (p < 0.001). Squeaking did not affect patient satisfaction, with 100% of the squeaking hips satisfied with the surgery. Conclusion LDH CoC THAs have demonstrated excellent functional outcomes at medium-term follow-up, with very low revision rate and no dislocations. The high incidence of squeaking did not affect patient satisfaction or function. LDH CoC with a monoblock acetabular component has the potential to provide long term implant survivorship with unrestricted activity, while avoiding implant impingement, liner fracture at insertion, and hip instability. Cite this article: Bone Joint J 2018;100-B:1434–41.


2006 ◽  
Vol 309-311 ◽  
pp. 1357-1362
Author(s):  
Masahiro Hasegawa ◽  
Akihiro Sudo ◽  
Atsumasa Uchida

In ceramic-on-ceramic total hip arthroplasty (THA), modular acetabular component with a sandwich insertion was developed and evaluated mid-term clinical results. 35 hips had undergone cementless ceramic-on-ceramic THA with sandwich cup (Kyocera, Kyoto, Japan). The mean duration of follow-up was 5 years. 6 hips had undergone component revisions. The reasons for revision included infection in 1 hip, dislocation with loosening in 2 hips, alumina liner fractures in 2 hips, and cup dissociation in 1 hip. All femoral and acetabular components showed no loosening in the unrevised hips at the time of the last follow-up. None of the 29 unrevised hips had osteolysis.


2018 ◽  
Vol 29 (1) ◽  
pp. 65-71 ◽  
Author(s):  
Yoshitoshi Higuchi ◽  
Taisuke Seki ◽  
Yukiharu Hasegawa ◽  
Yasuhiko Takegami ◽  
Daigo Morita ◽  
...  

Introduction: This study aimed to compare the clinical and radiographic results of 28-mm ceramic-on-ceramic (CoC) total hip arthroplasty (THA) to those of 32-mm CoC during a 5- to 15-year follow-up period. Methods: 107 joints (95 women and 6 men) underwent 28-mm CoC, and 60 (49 women and 7 men) underwent 32-mm CoC. The average patient age at the time of surgery was 56.1 and 55.7 years in the 28-mm and 32-mm CoC groups, respectively. Clinical and radiologic measurements of all patients were analysed. Results: The mean preoperative Harris hip score (HHS) was similar in the 2 groups (28-mm, 58.9; and 32-mm, 58.5). However, at final follow-up, the mean HHS of the 32-mm CoC (91.8) was significantly better than that of the 28-mm CoC (88.2) ( p = 0.003), as were the ranges of motion (ROM) for flexion (98.3 ± 13.5° vs. 87.3 ± 19.3°, p < 0.001) and abduction (27.8 ± 14.9° vs. 22.1 ± 19.3°, p = 0.007). The mean wear rate was 0.0044 mm/year for the 28-mm CoC and 0.0044 mm/year for the 32-mm CoC. No ceramic fractures were found in the 2 groups. One joint in the 28-mm CoC (0.9%) required revision owing to progressive osteolysis. Kaplan-Meier survival at 10 years, with implant loosening or revision THA as the endpoint, was 98.3% for 28-mm CoC and 100% for 32-mm CoC ( p = 0.465). Conclusion: There was no significant difference in ceramic-related complications between the 2 groups. Our study demonstrated that the 32-mm and 28-mm CoC are safe and are associated with good clinical outcomes.


Sign in / Sign up

Export Citation Format

Share Document