Early Transjugular Intrahepatic Portosystemic Shunt Creation Compared to Endoscopy With Pharmacotherapy in the Management of Variceal Rebleeding in Cirrhotic Patients: A Comprehensive Systematic Review and Meta-Analysis: Presidential Poster Award

2018 ◽  
Vol 113 (Supplement) ◽  
pp. S313
Author(s):  
Yousef Nassar ◽  
Seth J. Richter
2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Jiangtao Liu ◽  
Eric Paul Wehrenberg-Klee ◽  
Emily D. Bethea ◽  
Raul N. Uppot ◽  
Kei Yamada ◽  
...  

Introduction. Hepatic encephalopathy (HE) following transjugular intrahepatic portosystemic shunt (TIPS) placement remains a leading adverse event. Controversy remains regarding the optimal stent diameter given that smaller stents may decrease the amount of shunted blood and decrease the risk of HE, but stent patency and/or clinical adequacy of portal decompression may also be affected. We aim to provide meta-analysis-based evidence regarding the safety and efficacy of 8 mm vs. 10 mm stents during TIPS placement. Methods. PubMed, Embase, Cochrane Library, and Web of Science were searched for studies comparing 8 mm and 10 mm stents during TIPS placement for portal hypertension decompression in cirrhotic patients. Randomized controlled trials and cohort studies were prioritized for inclusion. Overall evaluation of quality and bias for each study was performed. The outcomes assessed were the prevalence of HE, rebleeding or failure to control refractory ascites, and overall survival. Subgroup analysis based on TIPS indication was conducted. Results. Five studies with a total number of 489 cirrhotic patients were identified. The pooled hazard ratio (HR) of post-TIPS HE was significantly lower in patients in the 8 mm stent group than in the 10 mm stent group (HR: 0.68, 95% CI: 0.51~0.92, p value < 0.0001). The combined HR of post-TIPS rebleeding/the need for paracentesis was significantly higher in patients in the 8 mm stent group than in the 10 mm stent group (HR: 1.76, 95% CI: 1.22~2.55, p value < 0.0001). There was no statistically significant difference in the overall survival between the 8 mm and 10 mm stent groups. The combined risk of HE in the variceal bleeding subgroup was statistically lower (HR: 0.52, CI: 0.34-0.80) with an 8 mm stent compared with a 10 mm stent. The combined risk of both rebleeding/paracentesis and survival was not statistically significant between 8 mm and 10 mm stent use in subgroup analysis. Conclusion. 8 mm stents during TIPS placement are associated with a significant lower risk of HE compared to 10 mm stents (32% decreased risk), as well as a 76% increased risk of rebleeding/paracentesis. Meta-analysis results suggest that there is not one superior stent choice for all clinical scenarios and that the TIPS indication of variceal bleeding or refractory ascites might have different appropriate selection of the shunt diameter.


Sign in / Sign up

Export Citation Format

Share Document