scholarly journals Modular Necks and Corrosion - Review of Five Cases

2016 ◽  
Vol 6 (3) ◽  
Author(s):  
Timothy McTighe ◽  
Declan Brazil

This report updates previous articles and commentary presented on Modular Necks from our Tissue Sparing Implant Study Group. In July 2012 we reported that at two years post-op we had encountered no modular neck taper failures or any signs of fretting corrosion, or pseudo tumors associated with the ARC™ Stem.Today we describe five patients out of five hundred and forty-two who had total hip arthroplasty revision [titanium alloy stem, cobalt-chromium modular neck (c.c.) and c.c. modular head (32 mm or 36 mm), highly-cross-linked polyethylene liner, metal titanium plasma sprayed cementless metal cup]. All patients’ were female and all demonstrated progressive hip pain or late instability. All  had debridement of the periarticular soft tissue, stem extraction with new primary length cementless stem replacement. At revision and early follow up all patients are doing well, however, we recommend heighten awareness in all active female patients with modular neck stem junctions.

2011 ◽  
Vol 6 (1) ◽  
pp. 39
Author(s):  

Background:Since the first reported use of percutaneous transluminal coronary angioplasty, advances in the interventional cardiology arena have been fast paced. Developers and clinicians are adapting from the learning curve awarded by the time-course of drug-eluting stent (DES) evolution. BioMime™ sirolimus-eluting stent (SES) is a step towards biomimicry. The stent is built on a strut of ultra-low thickness (65μm), a cobalt–chromium platform using an intelligent hybrid of closed and open cells allowing for morphology-mediated expansion. It employs a well-known antiproliferative – sirolimus – that elutes from a known biodegradable copolymer formulation within 30 days. The resultant stent demonstrates almost 100% endothelialisation at 30 days in preclinical models.Methods:The meriT-1 was a prospective, single-arm, single-centre trial to evaluate the safety and efficacy of BioMime SES in 30 patients with a single de novo lesion in native coronary arteries. The primary safety and efficacy end-points were major adverse cardiac events (MACE) at 30 days and in-stent late lumen loss at eight months, as measured using quantitative coronary angiographic (QCA) method. Secondary safety and efficacy end-points included MACE at one and two years and angiographic binary restenosis at eight-month angiographic follow-up. Other end-points included the occurrence of stent thrombosis at acute, subacute, late and very late periods and the percentage of diameter stenosis by QCA.Results:No MACE were observed and the median in-stent late luminal loss in 20 (67%) subjects studied by QCA was 0.15mm, with 0% binary restenosis at eight-month follow-up. No stent thrombosis was observed up to one-year follow-up.Conclusions:In comparison to currently available DES, BioMime SES appears to have a considerable scientific basis for prevention of neointimal proliferation, restenosis and associated clinical events.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Michał Waszczykowski ◽  
Bożena Dziankowska-Bartkowiak ◽  
Michał Podgórski ◽  
Jarosław Fabiś ◽  
Arleta Waszczykowska

AbstractThe aim of this study was to estimate the long-term results of complex and supervised rehabilitation of the hands in systemic sclerosis (SSc) patients. Fifty-one patients were enrolled in this study: 27 patients (study group) were treated with a 4-week complex, supervised rehabilitation protocol. The control group of 24 patients was prescribed a home exercise program alone. Both groups were evaluated at baseline and after 1-, 3-, 6-, and 12-months of follow-up with the Disability of the Arm, Shoulder and Hand Questionnaire (DAHS) as the primary outcome, pain (VAS—visual analog scale), Cochin Hand Function Scale (CHFS), Health Assessment Questionnaire Disability Index (HAQ-DI), Scleroderma-HAQ (SHAQ), range of motion (d-FTP—delta finger to palm, Kapandji finger opposition test) and hand grip and pinch as the secondary outcomes. Only the study group showed significant improvements in the DASH, VAS, CHFS and SHAQ after 1, 3 and 6 months of follow-up (P = 0.0001). Additionally, moderate correlations between the DASH, CHFS and SHAQ (R = 0.7203; R = 0.6788; P = 0.0001) were found. Complex, supervised rehabilitation improves hand and overall function in SSc patients up to 6 months after the treatment but not in the long term. The regular repetition of this rehabilitation program should be recommended every 3–6 months to maintain better hand and overall function.


2020 ◽  
Vol 35 (1) ◽  
Author(s):  
Ramy Teama ◽  
Mohamed Adawy ◽  
Mohamed Emara

Abstract Background The surgery of giant intracranial meningiomas (GIM) is difficult due to its large size, prominent vascularity, including and limiting visualization of various neurovascular structures, and severe cerebral edema. In this study, we will evaluate the surgical outcome of giant meningiomas according to our experience at our hospital in management of giant intracranial meningioma. Main body A retrospective analysis of 48 patients with histologically proven meningioma (≥ 6-cm diameter) who underwent surgical treatment at Benha University hospitals over a period of 5 years (June 2014/June 2019) is presented. Details regarding clinical presentation, imaging findings, surgical results and complications, and follow-up status were collected. The study group was composed of 41 females and 7 males. The age of the study group ranged from 38 to 69 years with an average of 49 years. The mean follow-up period was 36 months. Different approaches were used according to tumor location with the aim of gross total removal. Gross total removal was achieved in 90% of cases (43 cases). There were 2 cases with intraoperative complications not related to surgery. Recurrence was present in 4 cases. Mortality in this series was 4% (2 cases) with no reported intraoperative mortality. Conclusion Management of giant intracranial meningioma is a relatively common practice in neurosurgical centers in developing countries with the aim of radical total surgical removal being the first and most optimum option. Large size makes surgery difficult, but young age, meticulous surgical techniques, proper localization, trying to minimize operative time, and Simpson grade are of special value. Interdisciplinary cooperation is essential to avoid the common complications like pulmonary embolism (PE), postoperative hematoma in tumor bed that leads to bad surgical outcome.


2019 ◽  
Vol 8 (4) ◽  
pp. 504 ◽  
Author(s):  
Pietro Gentile ◽  
Donato Casella ◽  
Enza Palma ◽  
Claudio Calabrese

The areas in which Stromal Vascular Fraction cells (SVFs) have been used include radiotherapy based tissue damage after mastectomy, breast augmentation, calvarial defects, Crohn’s fistulas, and damaged skeletal muscle. Currently, the authors present their experience using regenerative cell therapy in breast reconstruction. The goal of this study was to evaluate the safety and efficacy of the use of Engineered Fat Graft Enhanced with Adipose-derived Stromal Vascular Fraction cells (EF-e-A) in breast reconstruction. 121 patients that were affected by the outcomes of breast oncoplastic surgery were treated with EF-e-A, comparing the results with the control group (n = 50) treated with not enhanced fat graft (EF-ne-A). The preoperative evaluation included a complete clinical examination, a photographic assessment, biopsy, magnetic resonance (MRI) of the soft tissue, and ultrasound (US). Postoperative follow-up took place at two, seven, 15, 21, 36 weeks, and then annually. In 72.8% (n = 88) of breast reconstruction treated with EF-e-A, we observed a restoration of the breast contour and an increase of 12.8 mm in the three-dimensional volume after 12 weeks, which was only observed in 27.3% (n = 33) of patients in the control group that was treated with EF-ne-A. Transplanted fat tissue reabsorption was analyzed with instrumental MRI and US. Volumetric persistence in the study group was higher (70.8%) than that in the control group (41.4%) (p < 0.0001 vs. control group). The use of EF-e-A was safe and effective in this series of treated cases.


2008 ◽  
Vol 122 (10) ◽  
pp. 1088-1091 ◽  
Author(s):  
N Jayashankar ◽  
K P Morwani ◽  
M J Shaan ◽  
S R Bhatia ◽  
K T Patil

AbstractGold eyelid implantation is widely considered the procedure of choice to reanimate the upper eyelid in paralytic lagophthalmos. Commercially supplied implants are not readily available in all places and are sometimes cumbersome to import.Objective:We aimed to devise a method whereby every surgeon performing gold eyelid implantation could have easy and quick access to the implant. Furthermore, we aimed to develop a means of creating an implant of the exact weight required for complete eyelid closure.Study design and setting:A prospective study was performed from 1997 to 2005 in a tertiary research hospital, involving 50 subjects requiring gold upper eyelid implantation and using the technique in question.Results:Only patients with a minimum follow up of one year were included in the study group. Symptoms improved in 96 per cent of subjects, who were able to dispense with eyedrops and eye ointments. Visual acuity improved in 92 per cent of patients. There were two extrusions amongst the early cases.Conclusion and significance:Customised gold eyelid implantation offers an alternative in regions where commercial implants are not easily obtained.


2002 ◽  
Vol 92 (10) ◽  
pp. 555-562 ◽  
Author(s):  
Jeffrey S. Boberg ◽  
Molly S. Judge

A retrospective radiographic review was performed of 29 patients (37 feet) who underwent an isolated medial approach for correction of hallux abducto valgus deformity from March 1993 to November 1998. Only those patients who had a traditional Austin-type osteotomy with a reducible first metatarsophalangeal joint and flexible first ray were included in the study. The average follow-up period for the entire study group was 18.4 months, with 13 patients (44.83%; 17 feet) having a follow-up period of longer than 2 years. The average decrease in the intermetatarsal angle was 9.89°, and the average decrease in the hallux abductus angle was 14.0°, results that correlated well with those of other studies on correction of hallux abducto valgus. No clinical or radiographic recurrence of hallux abducto valgus was noted throughout the follow-up period. The authors believe that an isolated medial approach to hallux abducto valgus correction without a lateral interspace release yields predictable results when performed in appropriately selected patients. (J Am Podiatr Med Assoc 92(10): 555-562, 2002)


2021 ◽  
pp. 036354652098197
Author(s):  
Akira Tsujii ◽  
Yasukazu Yonetani ◽  
Kazutaka Kinugasa ◽  
Tomohiko Matsuo ◽  
Kenji Yoneda ◽  
...  

Background: Meniscal function after repair of longitudinal tears of the lateral meniscus (LM) with anterior cruciate ligament reconstruction (ACLR) has not been comprehensively investigated. Purpose: To evaluate not only the clinical outcomes and radiographic findings of patients who underwent repair of longitudinal tears of the LM combined with ACLR but also the healing status of the repaired meniscus and changes in chondral status with second-look arthroscopy. Study Design: Case series; Level of evidence, 4. Methods: Among 548 patients who underwent primary anatomic ACLR at our institution between 2010 and 2017, 39 who had concomitant longitudinal tears of the LM and underwent repair were studied. During follow-up for more than 2 years, all patients were evaluated clinically (pain, range of motion, swelling, and knee instability) and with imaging (plain radiograph and magnetic resonance imaging [MRI]), and compared with a matched control group (based on age, sex, body mass index, and follow-up period) without any concomitant injuries who underwent ACLR. Measurements on MRI were recorded preoperatively, immediately after surgery, and at final follow-up, and the change in the values over time was assessed. Of the 39 patients in each group, 24 were assessed by second-look arthroscopy with hardware removal 2 years postoperatively. Results: The mean follow-up times of the study and control group were at a mean of 42.4 and 45.4 months, respectively. There were no significant differences in clinical findings, lateral joint space narrowing on radiographs, and chondral status at the lateral compartment between groups, whereas lateral and posterior meniscal extrusion on MRI progressed significantly in the study group (0.43 ± 1.0 mm vs -0.29 ± 1.1 mm, P = .003; 1.9 ± 1.9 mm vs 0.14 ± 1.1 mm, P < .0001, respectively). Second-look arthroscopy revealed complete healing in 12 patients (50%), partial healing in 9 (37.5%), and failure in 3 (12.5%) in the study group, and no new tear in the control group. Conclusion: The clinical and imaging outcomes after repair of longitudinal tears of the LM combined with anatomic ACLR were successful and comparable with those after isolated ACLR without any other injuries at 42 months postoperatively, although meniscal extrusion showed progression on coronal/sagittal MRI. Based on the MRI findings and the result that only half of patients achieved complete healing, meniscal function could not be fully restored even after repair. Although degenerative changes were not apparent, longer-term follow-up is needed.


Author(s):  
Juan Vivanco‐Suarez ◽  
Alan Mendez‐Ruiz ◽  
Farooqui Mudassir ◽  
Cynthia B Zevallos ◽  
Milagros Galecio‐Castillo ◽  
...  

Introduction : Flow diversion has established itself as standard treatment of wide complex intracranial aneurysms (IA). Its recognition has been validated with positive occlusion rates and favorable clinical outcomes. The Surpass Streamline (SS) flow diverter (FD) is a braided cobalt/chromium alloy implant with 72 or 96 wires approved by the FDA in 2018. The aim of this study is to determine the safety and efficacy of the SS in a post‐marketing large US cohort. Methods : We performed a multicenter, retrospective study for consecutive patients treated with the SS FD for IA between January 2018 and June 2021 in the United States. Inclusion criteria for participants were: 1. Adults (≥ 18 years) and 2. Treatment with SS FD for IA. Primary safety end point was a major ipsilateral stroke (increase in National Institutes of Health Stroke Scale Score of ≥ 4) or neurological death within 12 months. Primary efficacy was assessed using the 3‐point Raymond‐Roy (RR) occlusion scale on digital subtraction angiography (DSA) at 6‐12‐month follow‐up. Results : A total of 276 patients with 313 aneurysms were enrolled. The median age was 59 years and 199 (72%) were females. The most common comorbidities included hypertension in 156 (57%) subjects followed by hyperlipidemia in 76 (28%) patients. One hundred and twenty‐two (44%) patients were asymptomatic while subarachnoid hemorrhage was present in only 10 (4%) patients. A total of 143 (46%) aneurysms were left‐sided. Aneurysms were located as follows: 274 (88%) were in the anterior circulation with paraophthalmic being the most common in 120 (38%) followed by petrocavernous ICA in 81 (26%); 33 (11%) aneurysms were located in the posterior circulation with basilar trunk being the most common in 14 (5%). The mean maximum aneurysm dome width was 5.77 ± 4.7 mm, neck width 4.22 ± 3.8 mm and dome to neck ratio was 1.63 ± 1.3 mm. The mean number of SS FD implanted per aneurysm was 1.06 (range 1–3) with more than one SS FD implanted in 21 (7%) aneurysms. Modified Rankin Scale (mRS) of 0–2 was present in 206/213 (97%) patients at 6–12 month follow‐up. The complete aneurysm occlusion (RR 1) rate was 145/175 (83%) among subjects who had angiographic follow‐up at 6–12 months. Major stroke and death was encountered in 7 (2%) and 5 (1.8%) of the patients respectively. Conclusions : Our data represent the largest real‐world study using SS FD. These results corroborate its post‐marketing safety and efficacy for the treatment of intracranial aneurysms showing more favorable rates to the initial experience during SCENT trial.


Sign in / Sign up

Export Citation Format

Share Document