STRESS DEGRADATION STUDIES OF FUROSEMIDE AND DEVELOPMENT AND VALIDATION OF SIAM RP-HPLC METHOD FOR ITS QUANTIFICATION

Author(s):  
Mitesh Phale
Author(s):  
Charu P. Pandya ◽  
Sadhana J. Rajput

Objective: The objective of present work was to develop and validate simple, precise, accurate and specific stability indicating method for determination of acotiamide in presence of its degradation products.Methods: An isocratic RP-HPLC method has been developed using C-8 Thermo Hypersil BDS Column (250 x 4.6 mm i.d., 5µparticle size) with the mobile phase composition of acetonitrile: 0.1 % triethylamine in 0.2% formic acid (30: 70) at column oven temperature of 40 °C. The flow rate was 1.0 ml min-1 and effluent was detected at 282 nm. The method was validated in terms of linearity, accuracy, precision, LOD (Limit of Detection), LOQ (Limit of Quantification) and robustness as per ICH guidelines.Results: The method was found to be linear in the range of 10-60µg/ml. Limit of detection and limit of quantification was found to 0.36µg/ml and 1.10 µg/ml.% Recovery was found to be in the range of 99.45%-99.75%and precision less than 2%. The developed method was successfully applied for estimation of Acotiamide in marketed tablet formulation and percentage assay was found to be 100.45%. Acotiamide was subjected to stress degradation under acid, base, neutral hydrolysis, oxidation, dry heat, photolysis conditions. Significant degradation was observed in acid and base degradation.Conclusion: The developed RP-HPLC method was simple, rapid, accurate, precise and stability indicating for the estimation of Acotiamide in bulk and tablet dosage form.


2014 ◽  
Vol 50 (4) ◽  
pp. 895-901 ◽  
Author(s):  
Ramakrishna Kommana ◽  
Gouthami Kannabattula ◽  
Sunitha Gurrala ◽  
Venkat Raj Yeradesi ◽  
Panikumar Anumolu Durga

A simple, specific, precise, accurate, linear, rapid, economic and validated stability indicating an RP-HPLC method for the simultaneous quantification of cefepime and tazobactam in a dry injection dosage form has been developed. Separation was performed on a 5 µm ACE C18column with phosphate buffer, pH adjusted to 4.5 with phosphoric acid: methanol (70:30) at a flow rate of 1 mL/min and at a temperature of 25 °C. Regression analysis showed linearity at a detector wavelength of 290 nm in the range of 200-600 μg/mL for cefepime and 25-75 μg/mL for tazobactam. All of the analytes were adequately resolved with acceptable tailing. The percentage content found for cefepime was 99.98% and of tazobactam was 99.49% in the parenteral formulation. The method was validated in terms of linearity, precision, accuracy, specificity, robustness and system suitability according to ICH guidelines. Stress degradation studies were performed on the placebo and drug products, drugs of interest were well resolved from the degradation products. The developed method was effectively applied for the simultaneous quantification of cefepime and tazobactam in a dry injection formulation.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Singaram Kathirvel ◽  
Rachakonda Sujatha ◽  
Mutukuri Risheela Pandit ◽  
Achanti Suneetha

Sign in / Sign up

Export Citation Format

Share Document