Solvent bar microextraction combined with HPLC-DAD for simultaneous determination of diuretics in human urine and plasma samples

Author(s):  
Nabil N. AL-Hashimi ◽  
Amjad H. El-Sheikh ◽  
Manal I. Alruwad ◽  
Mohanad M. Odeh

Background: A simple and powerful microextraction procedure, the solvent bar microextraction (SBME), was used for the simultaneous determination of two diuretics, furosemide and spironolactone in human urine and plasma samples, using high-performance liquid chromatography coupled with diode array detection (HPLC-DAD). Methods: The appropriate amount (2 µL) of 1-octanol as an organic solvent confined within (2.5 cm) of a porous hollow fiber micro-tube, sealed at both ends was used for this procedure. The conditions for the SBME were optimized in water and the analytical performance were examined in spiked human urine and plasma samples. Results: The optimized method exhibited good linearity (R2 > 0.997) over the studied range of higher than 33 to 104 µg L-1 for furosemide and spironolactone in urine and plasma samples, illustrating a satisfactory precision level with RSD values between 2.1% and 9.1%. Discussion: The values of the limits of detection were found to be in the range of 6.39 to 9.67 µg L-1, and extraction recovery˃ 58.8% for both diuretics in urine and plasma samples. The applicability and effectiveness of the proposed method for the determination of furosemide and spironolactone in patient urine samples were tested. Conclusion: In comparison with reference methods, the attained results demonstrated that SBME combined with HPLC-DAD was proved to be simple, inexpensive, and promising analytical technology for the simultaneous determination of furosemide and spironolactone in urine and plasma samples.

2020 ◽  
Vol 13 (11) ◽  
pp. 367
Author(s):  
Patrycja Olejarz ◽  
Grażyna Chwatko ◽  
Paweł Kubalczyk ◽  
Krystian Purgat ◽  
Rafał Głowacki ◽  
...  

Tenofovir disoproxil fumarate is widely used in the therapy of human immunodeficiency virus and hepatitis B virus; however, a high concentration of the prodrug effects kidney function damage. To control the effectiveness of kidney functions in treated patients, the level of creatinine in the body must be controlled. This work describes a simple, fast, and “plastic-waste” reducing method for the simultaneous determination of tenofovir and creatinine in human urine and plasma. In both assays, only 50 µL of body fluid was required. The tests were carried out by reversed phase high-performance liquid chromatography with UV detection. In urine samples, the limits of detection for tenofovir and creatinine were 4 µg mL−1 and 0.03 µmol mL−1, respectively. In plasma samples, the limits of detection were 0.15 µg mL−1 for tenofovir and 0.0003 µmol mL−1 for creatinine. The method was applied for the determination of tenofovir and creatinine in human urine and plasma samples. The biggest advantage of the elaborated method is the possibility to determine tenofovir and creatinine in one analytical run in both urine and plasma sample collected from HIV and HBV patients. The possibility to reduce the level of laboratory waste in a sample preparation protocol is in the mainstream of a new trend of analytical chemistry which is based on green chemistry.


2008 ◽  
Vol 24 (12) ◽  
pp. 1589-1592 ◽  
Author(s):  
Yuegang ZUO ◽  
Chengjun WANG ◽  
Jiping ZHOU ◽  
Amita SACHDEVA ◽  
Vanessa C. RUELOS

Sign in / Sign up

Export Citation Format

Share Document