Effective optimization of SARS-CoV-2 laboratory testing variables in an era of supply chain constraints

2020 ◽  
Vol 15 (15) ◽  
pp. 1483-1487
Author(s):  
Nikhil S Sahajpal ◽  
Ashis K Mondal ◽  
Allan Njau ◽  
Sudha Ananth ◽  
Kimya Jones ◽  
...  

RT-PCR-based assays for the detection of SARS-CoV-2 have played an essential role in the current COVID-19 pandemic. However, the sample collection and test reagents are in short supply, primarily due to supply chain issues. Thus, to eliminate testing constraints, we have optimized three key process variables: RNA extraction and RT-PCR reactions, different sample types and media to facilitate SARS-CoV-2 testing. By performing various validation and bridging studies, we have shown that various sample types such as nasopharyngeal swab, bronchioalveolar lavage and saliva, collected using conventional nasopharyngeal swabs, ESwab or 3D-printed swabs and, preserved in viral transport media, universal transport media, 0.9% sodium chloride or Amies media are compatible with RT-PCR assay for COVID-19. Besides, the reduction of PCR reagents by up to fourfold also produces reliable results.

2021 ◽  
Vol 156 (Supplement_1) ◽  
pp. S139-S139
Author(s):  
J C Lownik ◽  
J S Farrar ◽  
G Way ◽  
R K Martin

Abstract Introduction/Objective Since the start of the coronavirus disease 2019 (COVID-19) pandemic, molecular diagnostic testing for detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has faced substantial supply chain shortages and noteworthy delays in result reporting after sample collection. Supply chain shortages have been most evident in reagents for RNA extraction and rapid diagnostic testing. In this study, we explored the kinetic limitations of extraction-free rapid cycle RT-qPCR for SARS-CoV-2 virus detection using the commercially available capillary based LightCycler. Methods/Case Report We optimized reverse transcription and PCR under extraction-free and rapid thermocycling conditions utilizing hydrolysis probe-based detection methods using a Roche LightCycler. Results (if a Case Study enter NA) This protocol improves detection speed while maintaining the sensitivity and specificity of hydrolysis probe-based detection. Percentage agreement between the developed assay and previously tested positive patient samples was 97.6% (n= 40/41) and negative patient samples was 100% (40/40). We further demonstrate that using purified RNA, SARS-CoV-2 testing using extreme RT-PCR and product verification by melting can be completed in less than 3 minutes. Conclusion We developed a protocol for sensitive and specific RT-qPCR of SARS-CoV-2 RNA from nasopharyngeal swabs in less than 20 minutes, with minimal hands-on time requirements. Overall, these studies provide a framework for increasing the speed of SARS-CoV-2 and other infectious disease testing.


Author(s):  
Nikhil Shri Sahajpal ◽  
Ashis K Mondal ◽  
Allan Njau ◽  
Sudha Ananth ◽  
Arvind Kothandaraman ◽  
...  

The current gold-standard molecular diagnosis for COVID-19 is based on a multi-step assay involving RNA-extraction and RT-PCR analysis for the detection of SARS-CoV-2. RNA-extraction step has been a major rate-limiting step in implementing high-throughput screening for COVID-19 during this pandemic. Moreover, clinical laboratories are facing several challenges that include cost, reagents, instrumentation, turn-around time, trained personnel, and supply-chain constraints to efficiently implement and sustain testing. Cognizant of these limitations, we evaluated the extraction-free methods described in the literature and have developed an innovative, simplified and easy protocol employing limited reagents to extract RNA for subsequent RT-PCR analysis. Nasopharyngeal-swab samples were subjected to the following individual conditions: 65°C for 15 minutes; 80°C for 5 minutes; 90°C for 5 minutes or 80°C for 1 minute, and processed for direct RT-PCR. These groups were also compared with a supplemental protocol adding isopropanol-ethanol-water elution steps followed by RT-PCR assay. The direct RT-PCR assay did not detect SARS-CoV-2 within the various temperature incubation only groups, whereas, the 90°C for 5 minutes-isopropanol-ethanol-water method was found to be comparable to the FDA-EUA method. Evaluation of the performance metrics for 100 clinical samples demonstrated a sensitivity of 94.2% and a specificity of 100%. The limit of detection was ascertained to be ~40 copies/ml by absolute-quantification. The protocol presented for this assay employs limited reagents and yields results with high sensitivity. Additionally, it presents a simplified methodology that would be easier to implement in laboratories in limited resource countries in order to meet the high current COVID-19 testing needs.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


Viruses ◽  
2021 ◽  
Vol 13 (4) ◽  
pp. 615
Author(s):  
Allen Wing-Ho Chu ◽  
Cyril Chik-Yan Yip ◽  
Wan-Mui Chan ◽  
Anthony Chin-Ki Ng ◽  
Dream Lok-Sze Chan ◽  
...  

SARS-CoV-2 RT-PCR with pooled specimens has been implemented during the COVID-19 pandemic as a cost- and manpower-saving strategy for large-scale testing. However, there is a paucity of data on the efficiency of different nucleic acid extraction platforms on pooled specimens. This study compared a novel automated high-throughput liquid-based RNA extraction (LRE) platform (PHASIFYTM) with a widely used magnetic bead-based total nucleic acid extraction (MBTE) platform (NucliSENS® easyMAG®). A total of 60 pools of nasopharyngeal swab and 60 pools of posterior oropharyngeal saliva specimens, each consisting of 1 SARS-CoV-2 positive and 9 SARS-CoV-2 negative specimens, were included for the comparison. Real-time RT-PCR targeting the SARS-CoV-2 RdRp/Hel gene was performed, and GAPDH RT-PCR was used to detect RT-PCR inhibitors. No significant differences were observed in the Ct values and overall RT-PCR positive rates between LRE and MBTE platforms (92.5% (111/120] vs 90% (108/120]), but there was a slightly higher positive rate for LRE (88.3% (53/60]) than MBTE (81.7% (49/60]) among pooled saliva. The automated LRE method is comparable to a standard MBTE method for the detection of SAR-CoV-2 in pooled specimens, providing a suitable alternative automated extraction platform. Furthermore, LRE may be better suited for pooled saliva specimens due to more efficient removal of RT-PCR inhibitors.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Shan Wei ◽  
Esther Kohl ◽  
Alexandre Djandji ◽  
Stephanie Morgan ◽  
Susan Whittier ◽  
...  

AbstractThe COVID-19 pandemic has resulted in an urgent need for a rapid, point of care diagnostic testing that could be rapidly scaled on a worldwide level. We developed and tested a highly sensitive and robust assay based on reverse transcription loop mediated isothermal amplification (RT-LAMP) that uses readily available reagents and a simple heat block using contrived spike-in and actual clinical samples. RT-LAMP testing on RNA-spiked samples showed a limit of detection (LoD) of 2.5 copies/μl of viral transport media. RT-LAMP testing directly on clinical nasopharyngeal swab samples in viral transport media had an 85% positive percentage agreement (PPA) (17/20), and 100% negative percentage agreement (NPV) and delivered results in 30 min. Our optimized RT-LAMP based testing method is a scalable system that is sufficiently sensitive and robust to test for SARS-CoV-2 directly on clinical nasopharyngeal swab samples in viral transport media in 30 min at the point of care without the need for specialized or proprietary equipment or reagents. This cost-effective and efficient one-step testing method can be readily available for COVID-19 testing world-wide, especially in resource poor settings.


Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 363
Author(s):  
Vânia M. Moreira ◽  
Paulo Mascarenhas ◽  
Vanessa Machado ◽  
João Botelho ◽  
José João Mendes ◽  
...  

The rapid and accurate testing of SARS-CoV-2 infection is still crucial to mitigate, and eventually halt, the spread of this disease. Currently, nasopharyngeal swab (NPS) and oropharyngeal swab (OPS) are the recommended standard sampling techniques, yet, these have some limitations such as the complexity of collection. Hence, several other types of specimens that are easier to obtain are being tested as alternatives to nasal/throat swabs in nucleic acid assays for SARS-CoV-2 detection. This study aims to critically appraise and compare the clinical performance of RT-PCR tests using oral saliva, deep-throat saliva/posterior oropharyngeal saliva (DTS/POS), sputum, urine, feces, and tears/conjunctival swab (CS) against standard specimens (NPS, OPS, or a combination of both). In this systematic review and meta-analysis, five databases (PubMed, Scopus, Web of Science, ClinicalTrial.gov and NIPH Clinical Trial) were searched up to the 30th of December, 2020. Case-control and cohort studies on the detection of SARS-CoV-2 were included. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS 2). We identified 1560 entries, 33 of which (1.1%) met all required criteria and were included for the quantitative data analysis. Saliva presented the higher accuracy, 92.1% (95% CI: 70.0–98.3), with an estimated sensitivity of 83.9% (95% CI: 77.4–88.8) and specificity of 96.4% (95% CI: 89.5–98.8). DTS/POS samples had an overall accuracy of 79.7% (95% CI: 43.3–95.3), with an estimated sensitivity of 90.1% (95% CI: 83.3–96.9) and specificity of 63.1% (95% CI: 36.8–89.3). The remaining index specimens could not be adequately assessed given the lack of studies available. Our meta-analysis shows that saliva samples from the oral region provide a high sensitivity and specificity; therefore, these appear to be the best candidates for alternative specimens to NPS/OPS in SARS-CoV-2 detection, with suitable protocols for swab-free sample collection to be determined and validated in the future. The distinction between oral and extra-oral salivary samples will be crucial, since DTS/POS samples may induce a higher rate of false positives. Urine, feces, tears/CS and sputum seem unreliable for diagnosis. Saliva testing may increase testing capacity, ultimately promoting the implementation of truly deployable COVID-19 tests, which could either work at the point-of-care (e.g. hospitals, clinics) or at outbreak control spots (e.g., schools, airports, and nursing homes).


Plant Disease ◽  
2013 ◽  
Vol 97 (10) ◽  
pp. 1370-1374 ◽  
Author(s):  
Mohamad Chikh-Ali ◽  
Stewart M. Gray ◽  
Alexander V. Karasev

A multiplex reverse-transcription polymerase chain reaction (RT-PCR) assay was previously developed to identify a group of Potato virus Y (PVY) isolates with unusual recombinant structures (e.g., PVYNTN-NW and SYR-III) and to differentiate them from other PVY strains. In the present study, the efficiency of this multiplex RT-PCR assay was validated and extended considerably to include five additional strains and strain groups not tested before. To make the multiplex RT-PCR assay more applicable and suitable for routine virus testing and typing, it was modified by replacing the conventional RNA extraction step with the immunocapture (IC) procedure. The results obtained using well-characterized reference isolates revealed, for the first time, that this multiplex RT-PCR assay is an accurate and robust method to identify and differentiate the nine PVY strains reported to date, including PVYO (both PVYO and PVYO-O5), PVYN, PVYNA-N, PVYNTN, PVYZ, PVYE, PVY-NE11, PVYN-Wi, and PVYN:O, which is not possible by any of the previously reported RT-PCR procedures. This would make the IC-RT-PCR procedure presented here a method of choice to identify PVY strains and assess the strain composition of PVY in a given area. The IC-RT-PCR protocol was successfully applied to typing PVY isolates in potato leaf tissue collected in the field.


2005 ◽  
Vol 124 (1-2) ◽  
pp. 65-71 ◽  
Author(s):  
Boris Pastorino ◽  
Maël Bessaud ◽  
Marc Grandadam ◽  
Severine Murri ◽  
Hugues J. Tolou ◽  
...  

1999 ◽  
Vol 37 (3) ◽  
pp. 524-530 ◽  
Author(s):  
Arno C. Andeweg ◽  
Theo M. Bestebroer ◽  
Martijn Huybreghs ◽  
Tjeerd G. Kimman ◽  
Jan C. de Jong

This paper describes the development and evaluation of a new nested reverse transcription (RT)-PCR for the detection of rhinovirus in clinical samples. The nucleotide sequences of the 5′ noncoding regions of 39 rhinoviruses were determined in order to map the most conserved subregions. We designed a set of rhinovirus-specific primers and probes directed to these subregions and developed a new nested RT-PCR. The new assay includes an optimal RNA extraction method and amplicon identification with probe hybridization to discriminate between rhinoviruses and the closely related enteroviruses. It proved to be highly sensitive and specific. When tested on a dilution series of cultured viruses, the new PCR protocol scored positive at 10- to 100-fold-higher dilutions than a previously used nested RT-PCR. When tested on a collection of clinical samples obtained from 1,070 acute respiratory disease patients who had consulted their general practitioners, the new assay demonstrated a rhinovirus in 24% of the specimens, including all culture-positive samples, whereas the previously used PCR assay or virus culture detected a rhinovirus in only 3.5 to 6% of the samples. This new assay should help determine the disease burden associated with rhinovirus infections.


Author(s):  
Sofía N. Rodríguez Flores ◽  
Luis Mario Rodríguez-Martínez ◽  
Bernardita L. Reyes-Berrones ◽  
Nadia A. Fernández-Santos ◽  
Elthon J. Sierra-Moncada ◽  
...  

During the COVID-19 pandemic, a certified laboratory of Tamaulipas, Mexico has processed over 100,000 samples of COVID-19 suspected patients, working a minimum of 100 tests daily. Thus, it would be beneficial for such certified laboratories nationwide to reduce the time and cost involved in performing the diagnosis of COVID-19, from sample collection, transportation to local lab, processing of samples, and data acquisition. Here, 30 nasopharyngeal swab and saliva samples from the same COVID-19 individuals were assessed by a standard nucleic acid extraction protocol, including protein lysis with proteinase K followed by binding to column, washing, and elution, and by the SalivaDirect protocol based on protein lysis, skipping the other steps to reduce processing time and costs. The genomic RNA was amplified using a SARS-CoV-2 Real-Time PCR kit. A variation (P > 0.05) in the 95% CIs = 72.6%–96.7% was noted by using the SalivaDirect protocol and saliva samples (sensitivity of 88.2%) in comparison to those of standard protocol with oropharyngeal swab samples (95% CIs = 97.5%–100%; sensitivity of 100%) as reported elsewhere. However, when using nasopharyngeal swab samples in the SalivaDirect protocol (sensitivity of 93.6%; 95% CIs = 79.2%–99.2%), it was in concordance (P < 0.05) with those of the standard one. The logical explanation to this was that two samples with Ct values of 38, and 40 cycles for gene E produced two false negatives in the SalivaDirect protocol in relation to the standard one; thus, there was a reduction of the sensitivity of 6.4% in the overall assay performance.