scholarly journals Management of Urethral Obstruction in a Cat with Epidural Sacrococcygeal Anesthesia Guided by Electrical Neurostimulation

2021 ◽  
Vol 49 ◽  
Author(s):  
Simone Marques Caramalac ◽  
Bets-Saba Naate Naumann Cerqueira Leite ◽  
Silvana Marques Caramalac ◽  
Fabricio De Oliveira Frazilio ◽  
Mariana Isa Poci Palumbo

Background: The treatment for urethral obstruction in cats consists of catheterization, and for this, the cat must be sedated or anesthetized. Sacococcygeal epidural block has the advantage of being close to receptors related to nociception located in the spinal cord and it is safer because it represents lower risk of spinal cord injury or inadvertent application in the subarachnoid space, when compared to the lumbosacral epidural. Nerve stimulation through the neurolocator to identify the epidural space increases the accuracy of this technique. Thus, the objective is to report a case of epidural anesthesia with a sacrococcygeal approach guided by neurostimulation in a cat with urethral obstruction.Case: A 4-year-old male Siamese cat, weighing 4 kg, was referred to the veterinary care with a history of apathy and anorexia for 2 days. From the physical exam, the clinical diagnosis of urethral obstruction was made, and to desobstruction, we chose to perform sacrococcygeal epidural block. Initially, the patient was anesthetized with propofol (4 mg/kg) and midazolam (0.3 mg/kg). To perform the anesthetic block, the cat was placed in sternal decubitus with the hind limbs extended cranially to perform sacrococcygeal epidural block. The positive pole (cathode) was connected to the skin of the right inguinal region at the caudal aspect of the thigh and the neurostimulator was turned on and adjusted to 0.7 mA of stimulating current intensity, 0.1 ms duration and 1 Hz frequency. The needle for electrical neurolocation was introduced in the dorsal midline, perpendicular to the skin surface, between the spinous processes of S3-Cd1 in the skin. The exact injection point was obtained observed by the muscular response of the middle and distal third of the animal’s tail with the neurostimulator adjusted to 0.3 mA of intensity, in the same duration and frequency as before. The total volume of 0.9 mL (0.22 mL/kg) of solution containing the combination of 0.6 mL of 0.75% levobupivacaine and 0.3 mL of 2% lidocaine was injected. The success of the block was confirmed by the loss of reflexes of the pelvic limbs and anal sphincter 10 min after the administration of the anesthetic solution.Discussion: In this case, the use of the neurolocator helped to perform an effective sacrococcygeal block, allowing urethral catheterization without the addition of other analgesic agents. This technique desensitizes and relaxes muscles in the regions of the perineum, anus, distal colon and penis, being useful for performing urethral catheterization. The use of smaller anaesthetic volumes to perform sacrococcygeal block makes it possible to achieve a more localized anesthesia, without affecting the motor function of the pelvic limbs. However, in our report, using a combination of levobupivacaine and lidocaine, the pelvic limb block was also verified despite the low volume applied. A hypothesis that could justify the different responses in relation to the pelvic limb block compared to other studies would be due to the different physicalchemical properties of the drugs used. Lidocaine is known to be less fat-soluble than bupivacaine, so it tends to spread more through the epidural space, in order to result in more extensive blocks. The use of a neurostimulator using a fixed electric current of 0.7 mA, pulse 0.1 ms and a frequency of 1 Hz allowed the correct identification of the needle position for the application of the anesthetic. Keywords: local block, nerve stimulation, levobupivacaine, lidocaine.

2017 ◽  
Vol 41 (1) ◽  
pp. 119-124 ◽  
Author(s):  
Daniela Mehech ◽  
Melvin Mejia ◽  
Gregory A. Nemunaitis ◽  
John Chae ◽  
Richard D. Wilson

2017 ◽  
Vol 11 (4) ◽  
pp. 661-674 ◽  
Author(s):  
Kwang-Sup Song ◽  
Jae Hwan Cho ◽  
Jae-Young Hong ◽  
Jae Hyup Lee ◽  
Hyun Kang ◽  
...  

<p>Systematic literature review. To review the evidence from high-quality studies regarding the treatment of neuropathic pain originating specifically from spinal disorders. In general, treatment guidelines for neuropathic pain cover all its various causes, including medical disease, peripheral neuropathy, and cancer. However, the natural history of neuropathic pain originating from spinal disorders may differ from that of the pain originating from other causes or lesions. An expert research librarian used terms related to neuropathic pain and spinal disorders, disc herniation, stenosis, and spinal cord injury to search in MEDLINE, Embase, and Cochrane CENTRAL for primary research from January 2000 to October 2015. Among 2,313 potential studies of interest, 25 randomized controlled trials (RCTs) and 21 systematic reviews (SRs) were included in the analysis. The selection was decided based on the agreement of two orthopedic surgeons. There was a lack of evidence about medication for radiculopathy arising from disc herniation and stenosis, but intervention procedures, including epidural block, showed positive efficacy in radiculopathy and also limited efficacy in spinal stenosis. There was some evidence based on the short-term follow-up regarding surgery being superior to conservative treatments for radiculopathy and stenosis. There was limited evidence regarding the efficacy of pharmacological and electric or magnetic stimulation therapies for neuropathic pain after spinal cord injury. This review of RCTs and SRs with high-quality evidence found some evidence regarding the efficacy of various treatment modalities for neuropathic pain related specifically to spinal disorders. However, there is a need for much more supportive evidence.</p>


Sign in / Sign up

Export Citation Format

Share Document