scholarly journals The effects of deposition potential on the optical, morphological and mechanical properties of DLC films produced by electrochemical deposition technique at low voltages

2019 ◽  
Vol 37 (2) ◽  
pp. 166-172
Author(s):  
Naim Aslan ◽  
Necati Başman ◽  
Orhan Uzun ◽  
Mustafa Erkovan ◽  
Fahrettin Yakuphanoğlu

AbstractDiamond-like carbon (DLC) films were electrochemically deposited onto indium tin oxide (ITO) substrates using acetic acid and deionized water as electrolyte at low deposition voltages (2.4 V and 60 V). The transmittance of the films was investigated by UV spectrometry. Transmittance measurements versus wavelength revealed that the films transmit 86 % to 89 % light in visible region and band gap of the films varies between 3.87 eV and 3.89 eV. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) were used for structural characterization to evaluate surface morphology of the DLC films. The grain size and the surface roughness increased for the films prepared at higher deposition potential, while their measured average height decreased. The mechanical properties (hardness H and elastic modulus Er) were determined from load-displacement curves which were obtained by using nanoindentation method. Hardness and elastic modulus of the films increased as the deposition voltage of the films increased from 2.4 V to 60 V.

2000 ◽  
Vol 15 (4) ◽  
pp. 838-841
Author(s):  
Allen T. Chien ◽  
Tom Felter ◽  
James D. LeMay ◽  
Mehdi Balooch

The local mechanical properties of silica-reinforced silicone composites were investigated using a modified atomic force microscopy technique. Elastic modulus measurements (1.5 ± 0.1 MPa) are consistent with bulk measurements (1.9 MPa), and changes in the modulus at the surface of the composite samples (E = 1.5 to 3.5 MPa) were observed as a result of α-irradiation (dose = 1.7 × 1010 to 2.0 × 1012 α/cm2). The sensitivity of the technique was demonstrated by a detectable change in modulus at even the small dose of 1.7 × 1010 α/cm2. The penetration depth of the α-particles into the material, estimated to be 22 ± 2 μm from the sample edge, was determined by cross-section depth profiling; and modeling of the ion penetration depth using transport of ions in matter codes (24.4 ± 0.4 μm) closely matched experimental observations.


2019 ◽  
Vol 54 (15) ◽  
pp. 2065-2071 ◽  
Author(s):  
M Subbir Parvej ◽  
Xinnan Wang ◽  
Joseph Fehrenbach ◽  
Chad A Ulven

Kenaf ( Hibiscus cannabinus L.) fiber is being extensively used as a reinforcement material in composites due to its excellent mechanical properties. To use this fiber more efficiently, it is necessary to understand its mechanical properties at micro/nano meter scale. Despite the evidence of some past studies to determine the elastic modulus of kenaf fiber, most of them were performed on fiber bundles. Bundle-based method to find the elastic moduli has some obvious issues of foreign materials being present, incorrect gauge length, and sample diameter due to void spaces. These issues pose as obvious hurdles to determine the elastic modulus accurately. In this study, individual kenaf micro fiber was used to find elastic modulus in the radial direction. The radial elastic modulus of the fiber was characterized by atomic force microscopy-based nanoindentation. To determine the radial elastic modulus from the force versus sample deformation data, the extended Johnson–Kendall–Roberts model was used which considered adhesion force from the fiber surface. The radial elastic modulus of the kenaf fiber was found to be 2.3 GPa.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
J. K. Wenderott ◽  
Carmen G. Flesher ◽  
Nicki A. Baker ◽  
Christopher K. Neeley ◽  
Oliver A. Varban ◽  
...  

AbstractObesity-related type 2 diabetes (DM) is a major public health concern. Adipose tissue metabolic dysfunction, including fibrosis, plays a central role in DM pathogenesis. Obesity is associated with changes in adipose tissue extracellular matrix (ECM), but the impact of these changes on adipose tissue mechanics and their role in metabolic disease is poorly defined. This study utilized atomic force microscopy (AFM) to quantify difference in elasticity between human DM and non-diabetic (NDM) visceral adipose tissue. The mean elastic modulus of DM adipose tissue was twice that of NDM adipose tissue (11.50 kPa vs. 4.48 kPa) to a 95% confidence level, with significant variability in elasticity of DM compared to NDM adipose tissue. Histologic and chemical measures of fibrosis revealed increased hydroxyproline content in DM adipose tissue, but no difference in Sirius Red staining between DM and NDM tissues. These findings support the hypothesis that fibrosis, evidenced by increased elastic modulus, is enhanced in DM adipose tissue, and suggest that measures of tissue mechanics may better resolve disease-specific differences in adipose tissue fibrosis compared with histologic measures. These data demonstrate the power of AFM nanoindentation to probe tissue mechanics, and delineate the impact of metabolic disease on the mechanical properties of adipose tissue.


2002 ◽  
Vol 283 (4) ◽  
pp. C1219-C1227 ◽  
Author(s):  
Amy M. Collinsworth ◽  
Sarah Zhang ◽  
William E. Kraus ◽  
George A. Truskey

The effect of differentiation on the transverse mechanical properties of mammalian myocytes was determined by using atomic force microscopy. The apparent elastic modulus increased from 11.5 ± 1.3 kPa for undifferentiated myoblasts to 45.3 ± 4.0 kPa after 8 days of differentiation ( P< 0.05). The relative contribution of viscosity, as determined from the normalized hysteresis area, ranged from 0.13 ± 0.02 to 0.21 ± 0.03 and did not change throughout differentiation. Myosin expression correlated with the apparent elastic modulus, but neither myosin nor β-tubulin were associated with hysteresis. Microtubules did not affect mechanical properties because treatment with colchicine did not alter the apparent elastic modulus or hysteresis. Treatment with cytochalasin D or 2,3-butanedione 2-monoxime led to a significant reduction in the apparent elastic modulus but no change in hysteresis. In summary, skeletal muscle cells exhibited viscoelastic behavior that changed during differentiation, yielding an increase in the transverse elastic modulus. Major contributors to changes in the transverse elastic modulus during differentiation were actin and myosin.


MRS Advances ◽  
2016 ◽  
Vol 1 (40) ◽  
pp. 2763-2768 ◽  
Author(s):  
Sergei Magonov ◽  
Marko Surtchev ◽  
John Alexander ◽  
Ivan Malovichko ◽  
Sergey Belikov

ABSTRACTRecent advances in studies of local mechanical properties of polymers with different atomic force microscopy techniques (contact, Hybrid and amplitude modulation modes) are described in interplay between experiment and theory. Analysis of force curves and time dependencies of probe response to sample compliance, which were recorded on a number of polymer materials at various temperatures, leads to quantitative mapping of specific mechanical properties (elastic modulus, work of adhesion, etc). High spatial resolution of elastic modulus mapping (10-20 nm) is illustrated in measurements of lamellar structures of several polymers. Challenges of examination of viscoelastic properties are pointed out and a possible solution is presented.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Shuting Zhang ◽  
Yihui Weng ◽  
Chunhua Ma

AbstractElastomeric nanostructures are normally expected to fulfill an explicit mechanical role and therefore their mechanical properties are pivotal to affect material performance. Their versatile applications demand a thorough understanding of the mechanical properties. In particular, the time dependent mechanical response of low-density polyolefin (LDPE) has not been fully elucidated. Here, utilizing state-of-the-art PeakForce quantitative nanomechanical mapping jointly with force volume and fast force volume, the elastic moduli of LDPE samples were assessed in a time-dependent fashion. Specifically, the acquisition frequency was discretely changed four orders of magnitude from 0.1 up to 2 k Hz. Force data were fitted with a linearized DMT contact mechanics model considering surface adhesion force. Increased Young’s modulus was discovered with increasing acquisition frequency. It was measured 11.7 ± 5.2 MPa at 0.1 Hz and increased to 89.6 ± 17.3 MPa at 2 kHz. Moreover, creep compliance experiment showed that instantaneous elastic modulus E1, delayed elastic modulus E2, viscosity η, retardation time τ were 22.3 ± 3.5 MPa, 43.3 ± 4.8 MPa, 38.7 ± 5.6 MPa s and 0.89 ± 0.22 s, respectively. The multiparametric, multifunctional local probing of mechanical measurement along with exceptional high spatial resolution imaging open new opportunities for quantitative nanomechanical mapping of soft polymers, and can potentially be extended to biological systems.


2018 ◽  
Vol 2 (2) ◽  
pp. 24-29
Author(s):  
Ahmed Kazaili ◽  
Riaz Akhtar

Understanding of the ultrastructure and nanomechanical behavior of the cornea is important for a number of ocular disorders. In this study, atomic force microscopy (AFM) was used to determine nanoscale changes in the porcine cornea following enzymatic degradation. Diff erent concentrations of amylase were used to degrade the cornea. A reduction in elastic modulus at the nanoscale, along with disrupted collagen morphology, was observed following enzymatic treatment. This study highlights the interplay between mechanical properties and collagen organization in the healthy cornea.


2021 ◽  
pp. 1-10
Author(s):  
Ngoc-Phat Huynh ◽  
Tuan-Em Le ◽  
Koo-Hyun Chung

Atomic force microscopy (AFM) can determine mechanical properties, associated with surface topography and structure, of a material at the nanoscale. Force–indentation curves that depict the deformation of a target specimen as a function of an applied force are widely used to determine the elastic modulus of a material based on a contact model. However, a hysteresis may arise due to friction between the AFM tip and a specimen. Consequently, the normal force detected using a photodetector during extension and retraction could be underestimated and overestimated, respectively, and the extension/retraction data could result in a significant difference in the elastic modulus measurement result. In this study, elastic modulus and friction coefficient values were determined based on an in situ theoretical model that compensated for the effect of friction on force–indentation data. It validated the proposed model using three different polymer specimens and colloidal-tipped probes for the force–indentation curve and friction loop measurements. This research could contribute to the accurate measurement of mechanical properties using AFM by enhancing the interpretation of force–indentation curves with friction-induced hysteresis. Furthermore, the proposed approach may be useful for analyzing in situ relationships between mechanical and frictional properties from a fundamental tribological perspective.


2010 ◽  
Vol 105-106 ◽  
pp. 348-350
Author(s):  
Hui Zhu ◽  
Jian Feng Huang ◽  
Li Yun Cao ◽  
Yan Wang ◽  
Xie Rong Zeng

Zinc sulphide (ZnS) thin films were deposited on the indium tin oxide (ITO) substrates by a novel, simple cathodic electrodeposition method under atmospheric pressure. These thin films were characterized by X-ray diffraction (XRD), atomic force microscopy (AFM) and photoluminescence spectrum (PL) at room temperature. The effects of deposition voltage on the phase composition, morphology and photoluminescence behavior of the thin films were investigated. XRD analysis shows that the deposited thin films is highly preferential growth along (200) orientation. Both AFM and XRD analyses indicate that the surface of the ZnS thin films is composed of uniform grains of around 50 nm in diameter. With the increase in the deposition voltages, the crystallization of the obtained thin films improves and the grain size of the ZnS thin films increases. Photoluminescence emission peaks are observed at at 475~490 nm and 500 ~530 nm at room temperature for an excitation of 210 nm.


Author(s):  
Samuel C. Lieber ◽  
Nadine Aubry ◽  
Jayashree Pain ◽  
Gissela Diaz ◽  
Song-Jung Kim ◽  
...  

Transverse mechanical properties of mammalian cardiac myocytes, was determined by using atomic force microscopy (AFM). The AFM can be used as a nano-indentation device allowing transverse stiffness measurements to be conducted on biological cells in a physiological environment. This enables real-time biomechanical and physiological processes to be monitored with nano-scale resolution. Cellular mechanical properties were determined by indenting the cell’s body, and analyzing the indentation data with classical infinitesimal strain theory (CIST). This calculation was accomplished by modeling the AFM probe as a blunted cone. The blunted cone geometry fits the AFM force indentation data well and was used to calculate the apparent elastic modulus of the cardiac myocyte body. The mechanical properties of male 344 x Brown Norway F1 hybrid (F344×BN) rat cells was measured and an apparent elastic modulus of 35.1 ± 0.7 kPa (n = 53) was calculated. Further studies are being conducted on myocytes isolated from aged hearts to determine whether age effects cardiac mechanical properties at the level of the single myocyte.


Sign in / Sign up

Export Citation Format

Share Document