Application of time-gated CCD camera with image intensifier in contactless detection of absorbing inclusions buried in optically turbid medium which mimics local changes in oxygenation of the brain tissue

2012 ◽  
Vol 20 (4) ◽  
Author(s):  
P. Sawosz ◽  
N. Zolek ◽  
M. Kacprzak ◽  
R. Maniewski ◽  
A. Liebert

AbstractThe near infrared spectroscopy may be implemented using various optoelectronic techniques, however, most of them do not allow to carry out measurements at short source-detector separation. We propose a method, based on time-gated intensified CCD camera, which allows for contactless measurements and can be carried out at short source-detector separation. This technique was tested on a phantom with absorbing inclusions buried in an optically turbid medium which mimics local changes in oxygenation of the brain tissue.

2021 ◽  
Vol 22 (3) ◽  
pp. 1122
Author(s):  
Mario Forcione ◽  
Mario Ganau ◽  
Lara Prisco ◽  
Antonio Maria Chiarelli ◽  
Andrea Bellelli ◽  
...  

The brain tissue partial oxygen pressure (PbtO2) and near-infrared spectroscopy (NIRS) neuromonitoring are frequently compared in the management of acute moderate and severe traumatic brain injury patients; however, the relationship between their respective output parameters flows from the complex pathogenesis of tissue respiration after brain trauma. NIRS neuromonitoring overcomes certain limitations related to the heterogeneity of the pathology across the brain that cannot be adequately addressed by local-sample invasive neuromonitoring (e.g., PbtO2 neuromonitoring, microdialysis), and it allows clinicians to assess parameters that cannot otherwise be scanned. The anatomical co-registration of an NIRS signal with axial imaging (e.g., computerized tomography scan) enhances the optical signal, which can be changed by the anatomy of the lesions and the significance of the radiological assessment. These arguments led us to conclude that rather than aiming to substitute PbtO2 with tissue saturation, multiple types of NIRS should be included via multimodal systemic- and neuro-monitoring, whose values then are incorporated into biosignatures linked to patient status and prognosis. Discussion on the abnormalities in tissue respiration due to brain trauma and how they affect the PbtO2 and NIRS neuromonitoring is given.


2019 ◽  
Vol 16 (11) ◽  
pp. 115602
Author(s):  
D M Kustov ◽  
A S Sharova ◽  
V I Makarov ◽  
A V Borodkin ◽  
T A Saveleva ◽  
...  

2021 ◽  
Author(s):  
Faezeh Moradi ◽  
Shima T. Moein ◽  
Issa Zakeri ◽  
Kambiz Pourrezaei

AbstractAn objective approach for odor detection is to analyze the brain activity using imaging techniques during the odor stimulation. In this study, Functional Near Infrared Spectroscopy (fNIRS) is used to record hemodynamic response from the frontal region of the brain by using a 4-channel fNIRS system. The fNIRs data is collected during the odor detection task in which the subjects were asked to press a button when they detect the given odor. Functional Data Analysis (FDA) was applied on fNIRs data to convert discrete measured samples of data to continuous smooth curves. The FDA method enables us to use the bases coefficients of fNIRS smoothed curves for features that represent the shape of the raw fNIRS signal. With the learning algorithm that we proposed, these features were used to train the support vector machine classifier. We evaluated the odor detection problem, in two binary classification cases: odorant vs. non-odorant and odorant vs. fingertapping. The model achieved a classification accuracy of 94.12% and 97.06% over the stimulus condition in the two cases, respectively. Moreover to find the actual predictors we used the extracted defined features (slope, standard deviation, and delta) to train our classifier. We achieved an average accuracy of 91.18 % on classifying odorant vs. non-odorant and an accuracy of 94.12% for odorant vs. fingertapping on the stimulus condition. The results determined that fNIRs signals of odorant and non-odorant are distinguishable without being affected by the motor activity during the experiment.These findings suggest that fNIRs measurement on the forehead could be potentially used for objective and comparably inexpensive assessment of odor detection in cases that the subjective report is unreliable.


Biosensors ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 389
Author(s):  
Kogulan Paulmurugan ◽  
Vimalan Vijayaragavan ◽  
Sayantan Ghosh ◽  
Parasuraman Padmanabhan ◽  
Balázs Gulyás

Functional Near-Infrared Spectroscopy (fNIRS) is a wearable optical spectroscopy system originally developed for continuous and non-invasive monitoring of brain function by measuring blood oxygen concentration. Recent advancements in brain–computer interfacing allow us to control the neuron function of the brain by combining it with fNIRS to regulate cognitive function. In this review manuscript, we provide information regarding current advancement in fNIRS and how it provides advantages in developing brain–computer interfacing to enable neuron function. We also briefly discuss about how we can use this technology for further applications.


2016 ◽  
Vol 59 (2) ◽  
pp. 167-170 ◽  
Author(s):  
Takaaki Watanabe ◽  
Masato Ito ◽  
Fuyu Miyake ◽  
Ryo Ogawa ◽  
Masanori Tamura ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document