scholarly journals Perio-Prosthodontics Considerations in Removable Partial Denture: The Role of the Prosthodontist

2021 ◽  
Vol 30 (03) ◽  
pp. 219-227
Author(s):  
Muhammad Haider Amin Malik ◽  
◽  
Nazia Yazdanie

OBJECTIVE: To review the periodontal considerations associated with removable partial denture therapy. METHODOLOGY: Using a MEDLINE search, for "removable partial dentures periodontal", a total of 712 papers from peer-reviewed journals came in results. The MEDLINE search was made more specific by applying filters to the key phrase with other key words such as "periodontal evaluation"(140), "direct retainers"(77), "non-surgical periodontal"(8), "surgical periodontal"(180), "plaque"(249), "periodontal indices"(112), "tooth mobility,"(180) "periodontal maintenance,"(60) "splinting,"(198) and "split major connector"(2). Both in vivo and in vitro studies on the Perio-prosthodontic aspects of RPD treatment were included in the study pool whereas case Series and case reports were excluded. RESULT: A total of 1206 studies were collected from the search engine. After applying the exclusion criteria and filtering the duplicates a total of 95 studies were included for the narrative review. CONCLUSIONS: Out of all the factors, recall and oral and denture hygiene have the utmost importance. KEYWORDS: Perio-prosthodontics, removable partial denture, periodontal indices.

1996 ◽  
Vol 30 (6) ◽  
pp. 644-655 ◽  
Author(s):  
Denise M Coleman ◽  
H William Kelly ◽  
Bennie C Mcwilliams ◽  
Annette Pérez ◽  
Marc M Perreault

Objective To provide an overview of aerosol drug delivery during mechanical ventilation in the pediatric and adult populations. Data Sources Published articles and abstracts identified in a MEDLINE search (1984–July 1994) were reviewed. Study Selection All articles and abstracts found, including review articles, in vivo and in vitro studies, case reports, and case series pertaining to issues involving aerosol delivery during mechanical ventilation, were reviewed. No predetermined selection criteria were used to exclude studies. Data Extraction Percent delivery of the starting dose to either the patients or the various in vitro lung models, as well as each variable possibly affecting delivery for each study, were tabulated for each study reviewed. Data Synthesis The delivery of therapeutic aerosols to endotracheally intubated and mechanically ventilated patients presents a unique challenge for healthcare providers. Delivery can be affected by the diameter of the endotracheal tube and ventilator circuitry, type of ventilator, ventilator modes, type of delivery device, and how the delivery device is operated and introduced into the ventilator circuitry. The drug being aerosolized may behave differently from one delivery system to another. The proper operation of each device requires attention to positioning in the ventilator circuit as well as the mode of ventilation. Conclusions No apparent advantage exists for metered-dose inhalers with a large-volume adapter over jet nebulizers, as each method of delivery is capable of similar efficiency (5–15%). Sufficient attention to detail, including the use of an efficient nebulizer and/or adapter and proper placement and operating method, is required to provide optimal delivery. For bronchodilator administration, careful monitoring of outcomes will provide the most optimal dosing schedule.


2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Naseer Ahmed ◽  
Maria Shakoor Abbasi ◽  
Sara Haider ◽  
Nimra Ahmed ◽  
Syed Rashid Habib ◽  
...  

Objective. Analyzing and comparing the fit and accuracy of removable partial denture (RPDs) frameworks fabricated with CAD/CAM and rapid prototyping methods with conventional techniques. Materials and Methods. The present systematic review was carried out according to PRISMA guidelines. The search was carried out on PubMed/MEDLINE, Cochrane collaboration, Science direct, and Scopus scientific engines using selected MeSH keywords. The articles fulfilling the predefined selection criteria based on the fit and accuracy of removable partial denture (RPD) frameworks constructed from digital workflow (CAD/CAM; rapid prototyping) and conventional techniques were included. Results. Nine full-text articles comprising 6 in vitro and 3 in vivo studies were included in this review. The digital RPDs were fabricated in all articles by CAD/CAM selective laser sintering and selective laser melting techniques. The articles that have used CAD/CAM and rapid prototyping technique demonstrated better fit and accuracy as compared to the RPDs fabricated through conventional techniques. The least gaps between the framework and cast ( 41.677 ± 15.546   μ m ) were found in RPDs constructed through digital CAD/CAM systems. Conclusion. A better accuracy was achieved using CAD/CAM and rapid prototyping techniques. The RPD frameworks fabricated by CAD/CAM and rapid prototyping techniques had clinically acceptable fit, superior precision, and better accuracy than conventionally fabricated RPD frameworks.


2012 ◽  
Vol 82 (3) ◽  
pp. 228-232 ◽  
Author(s):  
Mauro Serafini ◽  
Giuseppa Morabito

Dietary polyphenols have been shown to scavenge free radicals, modulating cellular redox transcription factors in different in vitro and ex vivo models. Dietary intervention studies have shown that consumption of plant foods modulates plasma Non-Enzymatic Antioxidant Capacity (NEAC), a biomarker of the endogenous antioxidant network, in human subjects. However, the identification of the molecules responsible for this effect are yet to be obtained and evidences of an antioxidant in vivo action of polyphenols are conflicting. There is a clear discrepancy between polyphenols (PP) concentration in body fluids and the extent of increase of plasma NEAC. The low degree of absorption and the extensive metabolism of PP within the body have raised questions about their contribution to the endogenous antioxidant network. This work will discuss the role of polyphenols from galenic preparation, food extracts, and selected dietary sources as modulators of plasma NEAC in humans.


Planta Medica ◽  
2012 ◽  
Vol 78 (11) ◽  
Author(s):  
HM Lee ◽  
TG Ahn ◽  
CW Kim ◽  
HJ An
Keyword(s):  

1987 ◽  
Vol 26 (01) ◽  
pp. 1-6 ◽  
Author(s):  
S. Selvaraj ◽  
M. R. Suresh ◽  
G. McLean ◽  
D. Willans ◽  
C. Turner ◽  
...  

The role of glycoconjugates in tumor cell differentiation has been well documented. We have examined the expression of the two anomers of the Thomsen-Friedenreich antigen on the surface of human, canine and murine tumor cell membranes both in vitro and in vivo. This has been accomplished through the synthesis of the disaccharide terminal residues in both a and ß configuration. Both entities were used to generate murine monoclonal antibodies which recognized the carbohydrate determinants. The determination of fine specificities of these antibodies was effected by means of cellular uptake, immunohistopathology and immunoscintigraphy. Examination of pathological specimens of human and canine tumor tissue indicated that the expressed antigen was in the β configuration. More than 89% of all human carcinomas tested expressed the antigen in the above anomeric form. The combination of synthetic antigens and monoclonal antibodies raised specifically against them provide us with invaluable tools for the study of tumor marker expression in humans and their respective animal tumor models.


1971 ◽  
Vol 66 (3) ◽  
pp. 558-576 ◽  
Author(s):  
Gerald Burke

ABSTRACT A long-acting thyroid stimulator (LATS), distinct from pituitary thyrotrophin (TSH), is found in the serum of some patients with Graves' disease. Despite the marked physico-chemical and immunologic differences between the two stimulators, both in vivo and in vitro studies indicate that LATS and TSH act on the same thyroidal site(s) and that such stimulation does not require penetration of the thyroid cell. Although resorption of colloid and secretion of thyroid hormone are early responses to both TSH and LATS, available evidence reveals no basic metabolic pathway which must be activated by these hormones in order for iodination reactions to occur. Cyclic 3′, 5′-AMP appears to mediate TSH and LATS effects on iodination reactions but the role of this compound in activating thyroidal intermediary metabolism is less clear. Based on the evidence reviewed herein, it is suggested that the primary site of action of thyroid stimulators is at the cell membrane and that beyond the(se) primary control site(s), there exists a multifaceted regulatory system for thyroid hormonogenesis and cell growth.


2018 ◽  
Vol 8 (3) ◽  
pp. 36-41
Author(s):  
Diep Do Thi Hong ◽  
Duong Le Phuoc ◽  
Hoai Nguyen Thi ◽  
Serra Pier Andrea ◽  
Rocchitta Gaia

Background: The first biosensor was constructed more than fifty years ago. It was composed of the biorecognition element and transducer. The first-generation enzyme biosensors play important role in monitoring neurotransmitter and determine small quantities of substances in complex matrices of the samples Glutamate is important biochemicals involved in energetic metabolism and neurotransmission. Therefore, biosensors requires the development a new approach exhibiting high sensibility, good reproducibility and longterm stability. The first-generation enzyme biosensors play important role in monitoring neurotransmitter and determine small quantities of substances in complex matrices of the samples. The aims of this work: To find out which concentration of polyethylenimine (PEI) exhibiting the most high sensibility, good reproducibility and long-term stability. Methods: We designed and developed glutamate biosensor using different concentration of PEI ranging from 0% to 5% at Day 1 and Day 8. Results: After Glutamate biosensors in-vitro characterization, several PEI concentrations, ranging from 0.5% to 1% seem to be the best in terms of VMAX, the KM; while PEI content ranging from 0.5% to 1% resulted stable, PEI 1% displayed an excellent stability. Conclusions: In the result, PEI 1% perfomed high sensibility, good stability and blocking interference. Furthermore, we expect to develop and characterize an implantable biosensor capable of detecting glutamate, glucose in vivo. Key words: Glutamate biosensors, PEi (Polyethylenimine) enhances glutamate oxidase, glutamate oxidase biosensors


Sign in / Sign up

Export Citation Format

Share Document