scholarly journals Drinking Water Treatment Plants in Turkey and Determination of Revision Needs

2019 ◽  
Vol 3 (2) ◽  
pp. 44-57
Author(s):  
Esra Giresunlu ◽  
Arife Özüdoğru ◽  
Fulya Yaycılı ◽  
Hilal Uflaz ◽  
Cenk GÜMÜŞKAYA ◽  
...  
1986 ◽  
Vol 21 (3) ◽  
pp. 447-459 ◽  
Author(s):  
K.J. Roberts ◽  
R.B. Hunsinger ◽  
A.H. Vajdic

Abstract The Drinking Water Surveillance Program (DWSP), developed by the Ontario Ministry of the Environment, is an assessment project based on standardized analytical and sampling protocol. This program was recently instituted in response to a series of contaminant occurrences in the St. Clair-Detroit River area of Southwestern Ontario. This paper outlines the details and goals of the program and provides information concerning micro-contaminants in drinking water at seven drinking water treatment plants in Southwestern Ontario.


Author(s):  
Samantha Donovan ◽  
Ariel Jasmine Atkinson ◽  
Natalia Fischer ◽  
Amelia E Taylor ◽  
Johann Kieffer ◽  
...  

PolyDiallyldimethyl Ammonium Chloride (PolyDADMAC) is the most commonly used polymer at drinking water treatment plants and has the potential to form nitrosamines, like N-Nitrosodimethylamine (NDMA), if free polymer is present...


2000 ◽  
Vol 46 (6) ◽  
pp. 565-576 ◽  
Author(s):  
Pierre Payment ◽  
Aminata Berte ◽  
Michèle Prévost ◽  
Bruno Ménard ◽  
Benoît Barbeau

A 300-km portion of the Saint Lawrence hydrological basin in the province of Québec (Canada) and 45 water treatment plants were studied. River water used by drinking water treatment plants was analyzed (6-L sample volumes) to determine the level of occurrence of bacterial indicators (total coliforms, fecal coliforms, and Clostridium perfringens) and pathogens (Giardia lamblia, Cryptosporidium, human enteric viruses). Pathogens and bacterial indicators were found at all sites at a wide range of values. Logistic regression analysis revealed significant correlations between the bacterial indicators and the pathogens. Physicochemical and treatment practices data were collected from most water treatment plants and used to estimate the level of removal of pathogens achieved under cold (0°C-4°C) and warm (20°C-25°C) water temperature conditions. The calculated removal values were then used to estimate the annual risk of Giardia infection using mathematical models and to compare the sites. The estimated range of probability of infection ranged from 0.75 to less than 0.0001 for the populations exposed. Given the numerous assumptions made, the model probably overestimated the annual risk, but it provided comparative data of the efficacy of the water treatment plants and thereby contributes to the protection of public health.Key words: public health, drinking water, health risk, pathogen occurrence.


2009 ◽  
Vol 9 (4) ◽  
pp. 379-386 ◽  
Author(s):  
S. A. Baghoth ◽  
M. Dignum ◽  
A. Grefte ◽  
J. Kroesbergen ◽  
G. L. Amy

For drinking water treatment plants that do not use disinfectant residual in the distribution system, it is important to limit availability of easily biodegradable natural organic matter (NOM) fractions which could enhance bacterial regrowth in the distribution system. This can be achieved by optimising the removal of those fractions of interest during treatment; however, this requires a better understanding of the physical and chemical properties of these NOM components. Fluorescence excitation-emission matrix (EEM) and liquid chromatography with online organic carbon detection (LC-OCD) were used to characterize NOM in water samples from one of the two water treatment plants serving Amsterdam, The Netherlands. No disinfectant residual is applied in the distribution system. Fluorescence EEM and LC-OCD were used to track NOM fractions. Whereas fluorescence EEM shows the reduction of humic-like as well as protein-like fluorescence signatures, LC-OCD was able to quantify the changes in dissolved organic carbon (DOC) concentrations of five NOM fractions: humic substances, building blocks (hydrolysates of humics), biopolymers, low molecular weight acids and neutrals.


2012 ◽  
Vol 79 (2) ◽  
pp. 449-459 ◽  
Author(s):  
Ana Luz Galván ◽  
Angela Magnet ◽  
Fernando Izquierdo ◽  
Soledad Fenoy ◽  
Cristina Rueda ◽  
...  

ABSTRACTRecent studies suggest the involvement of water in the epidemiology ofCyclospora cayetanensisand some microsporidia. A total of 223 samples from four drinking water treatment plants (DWTPs), seven wastewater treatment plants (WWTPs), and six locations of influence (LI) on four river basins from Madrid, Spain, were analyzed from spring 2008 to winter 2009. Microsporidia were detected in 49% of samples (109/223),Cyclosporaspp. were detected in 9% (20/223), and both parasites were found in 5.4% (12/223) of samples. Human-pathogenic microsporidia were detected, includingEnterocytozoon bieneusi(C, D, and D-like genotypes),Encephalitozoon intestinalis,Encephalitozoon cuniculi(genotypes I and III), andAnncaliia algerae.C. cayetanensiswas identified in 17 of 20 samples. To our knowledge, this is the first study that shows a year-long longitudinal study ofC. cayetanensisin drinking water treatment plants. Additionally, data about the presence and molecular characterization of the human-pathogenic microsporidia in drinking water, wastewater, and locations of influence during 1 year in Spain are shown. It is noteworthy that although the DWTPs and WWTPs studied meet European and national regulations on water sanitary quality, both parasites were found in water samples from these plants, supporting the idea that new and appropriate controls and regulations for drinking water, wastewater, and recreational waters should be proposed to avoid health risks from these pathogens.


2017 ◽  
Vol 143 (3) ◽  
pp. 04016088 ◽  
Author(s):  
A. M. Hidalgo ◽  
M. D. Murcia ◽  
M. Gómez ◽  
E. Gómez ◽  
C. García-Izquierdo ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document