scholarly journals Concurrent Validity of Power From Three On-Water Rowing Instrumentation Systems and a Concept2 Ergometer

2021 ◽  
Vol 12 ◽  
Author(s):  
Ana C. Holt ◽  
William G. Hopkins ◽  
Robert J. Aughey ◽  
Rodney Siegel ◽  
Vincent Rouillard ◽  
...  

Purpose: Instrumentation systems are increasingly used in rowing to measure training intensity and performance but have not been validated for measures of power. In this study, the concurrent validity of Peach PowerLine (six units), Nielsen-Kellerman EmPower (five units), Weba OarPowerMeter (three units), Concept2 model D ergometer (one unit), and a custom-built reference instrumentation system (Reference System; one unit) were investigated.Methods: Eight female and seven male rowers [age, 21 ± 2.5 years; rowing experience, 7.1 ± 2.6 years, mean ± standard deviation (SD)] performed a 30-s maximal test and a 7 × 4-min incremental test once per week for 5 weeks. Power per stroke was extracted concurrently from the Reference System (via chain force and velocity), the Concept2 itself, Weba (oar shaft-based), and either Peach or EmPower (oarlock-based). Differences from the Reference System in the mean (representing potential error) and the stroke-to-stroke variability (represented by its SD) of power per stroke for each stage and device, and between-unit differences, were estimated using general linear mixed modeling and interpreted using rejection of non-substantial and substantial hypotheses.Results: Potential error in mean power was decisively substantial for all devices (Concept2, –11 to –15%; Peach, −7.9 to −17%; EmPower, −32 to −48%; and Weba, −7.9 to −16%). Between-unit differences (as SD) in mean power lacked statistical precision but were substantial and consistent across stages (Peach, ∼5%; EmPower, ∼7%; and Weba, ∼2%). Most differences from the Reference System in stroke-to-stroke variability of power were possibly or likely trivial or small for Peach (−3.0 to −16%), and likely or decisively substantial for EmPower (9.7–57%), and mostly decisively substantial for Weba (61–139%) and the Concept2 (−28 to 177%).Conclusion: Potential negative error in mean power was evident for all devices and units, particularly EmPower. Stroke-to-stroke variation in power showed a lack of measurement sensitivity (apparent smoothing) that was minor for Peach but larger for the Concept2, whereas EmPower and Weba added random error. Peach is therefore recommended for measurement of mean and stroke power.

2021 ◽  
Vol 33 (2) ◽  
pp. 65-69
Author(s):  
C. Eric Heidorn ◽  
Brandon J. Dykstra ◽  
Cori A. Conner ◽  
Anthony D. Mahon

Purpose: This study examined the physiological, perceptual, and performance effects of a 6% carbohydrate (CHO) drink during variable-intensity exercise (VIE) and a postexercise test in premenarchal girls. Methods: A total of 10 girls (10.4 [0.7] y) participated in the study. VO2peak was assessed, and the girls were familiarized with VIE and performance during the first visit. The trial order (CHO and placebo) was randomly assigned for subsequent visits. The drinks were given before VIE bouts and 1-minute performance (9 mL/kg total). Two 15-minute bouts of VIE were completed (10 repeated sequences of 20%, 55%, and 95% power at VO2peak and maximal sprints) before a 1-minute performance sprint. Results: The mean power, peak power, heart rate (HR), %HRpeak, and rating of perceived exertion during VIE did not differ between trials. However, the peak power decreased, and the rating of perceived exertion increased from the first to the second bout. During the 1-minute performance, there were no differences between the trial (CHO vs placebo) for HR (190 [9] vs 189 [9] bpm), %HRpeak (97.0% [3.2%] vs 96.6% [3.0%]), rating of perceived exertion (7.8 [2.3] vs 8.1 [1.9]), peak power (238 [70] vs 235 [60] W), fatigue index (54.7% [10.0%] vs 55.9% [12.8%]), or total work (9.4 [2.6] vs 9.4 [2.1] kJ). Conclusion: CHO supplementation did not alter physiological, perceptual, or performance responses during 30 minutes of VIE or postexercise sprint performance in premenarchal girls.


Sports ◽  
2019 ◽  
Vol 7 (10) ◽  
pp. 217 ◽  
Author(s):  
Arne Sørensen ◽  
Tore Kristian Aune ◽  
Vegar Rangul ◽  
Terje Dalen

Cycling is a popular sport, and evaluation of the validity of tests to predict performance in competitions is important for athletes and coaches. Similarity between performance in sprints in mass-start bike races and in the laboratory is found, but, to our knowledge, no studies have investigated the relationship between laboratory measurements of maximal oxygen uptake (VO2max) and functional threshold power (FTP) with performance in official mass-start competitions. The purpose of this study was to evaluate the validity of a 20 min FTP test and VO2max as predictors for performance in an official mountain bike competition. Eleven moderately trained male cyclists at a local level participated in this study (age: 43 ± 5.1 years; height: 183.4 ± 5.4 m; weight: 84.4 ± 8.7 kg; body mass index: 25.1 ± 2.1). All subjects performed a 20 min FTP test in the laboratory to measure the mean power. In addition, the subjects completed an incremental test to exhaustion to determine VO2max. These two laboratory tests were analyzed together with the results from a 47 km mass-start mountain bike race, with a total elevation of 851 m. A significant relationship was found between the mean relative power (W/kg) for the 20 min FTP test and performance time in the race (r = −0.74, P < 0.01). No significant correlation was found between VO2max and cycling performance for these subjects (r = −0.37). These findings indicate that a 20 min FTP test is a more valid test for prediction of performance in mass-start bike races than a VO2max test for moderately trained cyclists.


2019 ◽  
Vol 40 (12) ◽  
pp. 796-802 ◽  
Author(s):  
F. Javier Nuñez ◽  
Moisés de Hoyo ◽  
Alejandro Muñoz López ◽  
Borja Sañudo ◽  
Carlos Otero-Esquina ◽  
...  

AbstractThe aims of this study were to analyse the effect of chronic strength training over concentric power (CON), eccentric power (ECC), ECC/CON ratio, and 20 m linear sprint performance in elite young soccer players. Twenty young elite Spanish soccer players were assigned to an experimental group (CPG) which performed a front-step exercise using a conical pulley, 2–3 sets of 6 repetitions each leg, during 9 weeks (CPG, n=10) in addition to its usual strength training, or to a control group (CG, n=10). The improvements in the ECC mean power (36%, ES=1.61), and ECC / CON ratio (17%, ES=1.77) were substantially greater in the CPG than in the CG while the CON mean power (16%, ES=0.83) was substantially greater in the CG than in the CPG. The sprinting time for 10 m (2.8%, ES=0.78) and the 10 m flying time between 10–20 m (1.72%, ES=0.41) were substantially enhanced in CPG and CG respectively. To be efficient when defining a functional strength training and performance increments using an inertial device, the mean power output need to be measured during the CON and ECC phases and an analysis of the ECC / CON ratio should be included.


Author(s):  
Ching-Feng Cheng ◽  
Yu-Hsuan Kuo ◽  
Wei-Chieh Hsu ◽  
Chu Chen ◽  
Chi-Hsueh Pan

The aim of this study was to investigate the effects of local (LIPC) and remote (RIPC) ischemic preconditioning on sprint interval exercise (SIE) performance. Fifteen male collegiate basketball players underwent a LIPC, RIPC, sham (SHAM), or control (CON) trial before conducting six sets of a 30-s Wingate-based SIE test. The oxygen uptake and heart rate were continuously measured during SIE test. The total work in the LIPC (+2.2%) and RIPC (+2.5%) conditions was significantly higher than that in the CON condition (p < 0.05). The mean power output (MPO) at the third and fourth sprint in the LIPC (+4.5%) and RIPC (+4.9%) conditions was significantly higher than that in the CON condition (p < 0.05). The percentage decrement score for MPO in the LIPC and RIPC condition was significantly lower than that in the CON condition (p < 0.05). No significant interaction effects were found in pH and blood lactate concentrations. There were no significant differences in the accumulated exercise time at ≥80%, 90%, and 100% of maximal oxygen uptake during SIE. Overall, both LIPC and RIPC could improve metabolic efficiency and performance during SIE in athletes.


2018 ◽  
Vol 39 (10) ◽  
pp. 737-742 ◽  
Author(s):  
Fernando Borszcz ◽  
Artur Tramontin ◽  
Arthur Bossi ◽  
Lorival Carminatti ◽  
Vitor Costa

AbstractFunctional threshold power is defined as the highest power output a cyclist can maintain in a quasi-steady state for approximately 60 min (FTP60). In order to improve practicality for regular evaluations, FTP60 could theoretically be determined as 95% of the mean power output in a 20-min time trial (FTP20). This study tested this assumption and the validity of FTP20 and FTP60 against the individual anaerobic threshold (IAT). Twenty-three trained male cyclists performed an incremental test to exhaustion, 20- and 60-min time trials, and a time to exhaustion at FTP20. Power output, heart rate and oxygen uptake representing FTP20, FTP60 and IAT were not different (p>0.05), and large to very large correlations were found (r=0.61 to 0.88). Bland-Altman plots between FTP20, FTP60 and IAT showed small bias (–1 to –5 W), but large limits of agreement ([–40 to 32 W] to [–62 to 60 W]). Time to exhaustion at FTP20 was 50.9±15.7 min. In conclusion, FTP20 and FTP60 should not be used interchangeably on an individual basis and their validity against IAT should be interpreted with caution.


2000 ◽  
Vol 16 (2) ◽  
pp. 107-114 ◽  
Author(s):  
Louis M. Hsu ◽  
Judy Hayman ◽  
Judith Koch ◽  
Debbie Mandell

Summary: In the United States' normative population for the WAIS-R, differences (Ds) between persons' verbal and performance IQs (VIQs and PIQs) tend to increase with an increase in full scale IQs (FSIQs). This suggests that norm-referenced interpretations of Ds should take FSIQs into account. Two new graphs are presented to facilitate this type of interpretation. One of these graphs estimates the mean of absolute values of D (called typical D) at each FSIQ level of the US normative population. The other graph estimates the absolute value of D that is exceeded only 5% of the time (called abnormal D) at each FSIQ level of this population. A graph for the identification of conventional “statistically significant Ds” (also called “reliable Ds”) is also presented. A reliable D is defined in the context of classical true score theory as an absolute D that is unlikely (p < .05) to be exceeded by a person whose true VIQ and PIQ are equal. As conventionally defined reliable Ds do not depend on the FSIQ. The graphs of typical and abnormal Ds are based on quadratic models of the relation of sizes of Ds to FSIQs. These models are generalizations of models described in Hsu (1996) . The new graphical method of identifying Abnormal Ds is compared to the conventional Payne-Jones method of identifying these Ds. Implications of the three juxtaposed graphs for the interpretation of VIQ-PIQ differences are discussed.


Author(s):  
Ewa A. Burian ◽  
Lubna Sabah ◽  
Klaus Kirketerp-Møller ◽  
Elin Ibstedt ◽  
Magnus M. Fazli ◽  
...  

Acute wounds may require cleansing to reduce the risk of infection. Stabilized hypochlorous acid in acetic buffer (HOCl + buffer) is a novel wound irrigation solution with antimicrobial properties. We performed a first-in-man, prospective, open-label pilot study to document preliminary safety and performance in the treatment of acute wounds. The study enrolled 12 subjects scheduled for a split-skin graft transplantation, where the donor site was used as a model of an acute wound. The treatment time was 75 s, given on 6 occasions. A total of 7 adverse events were regarded as related to the treatment; all registered as pain during the procedure for 2 subjects. One subject had a wound infection at the donor site. The mean colony-forming unit (CFU) decreased by 41% after the treatment, and the mean epithelialization was 96% on both days 14 (standard deviation [SD] 8%) and 21 (SD 10%). The study provides preliminary support for the safety, well-tolerance, and efficacy of HOCl + buffer for acute wounds. The pain was frequent although resolved quickly. Excellent wound healing and satisfying antimicrobial properties were observed. A subsequent in vitro biofilm study also indicated good antimicrobial activity against Pseudomonas aeruginosa with a 96% mean reduction of CFU, when used for a treatment duration of 15 min ( P < .0001), and a 50% decrease for Staphylococcus aureus ( P = .1010). Future larger studies are needed to evaluate the safety and performance of HOCl + buffer in acute wounds, including the promising antimicrobial effect by prolonged treatment on bacterial biofilms.


2011 ◽  
Vol 24 (3) ◽  
pp. 382-390 ◽  
Author(s):  
Sebastian Voigt-Radloff ◽  
Rainer Leonhart ◽  
Matthias Schützwohl ◽  
Luisa Jurjanz ◽  
Thomas Reuster ◽  
...  

ABSTRACTBackground: The purpose of the study was to translate the Interview for Deterioration in Daily Living Activities in Dementia (IDDD) into German and to evaluate the construct and concurrent validity in people with mild to moderate dementia.Methods: IDDD data of two pooled samples (n = 301) were analyzed regarding ceiling and bottom effects, internal consistency, factor reliability and correlations with corresponding scales on cognition and activities of daily living.Results: We found minimal bottom (< 5%) and ceiling (≤ 2%) effects, good internal consistency (Cronbach's α > 0.7) and moderate to good factor reliability (0.66–0.87). Low correlations with cognition (Pearson coefficient: < 0.17) confirmed the differences between cognitive testing and activities of daily living (ADL). Minor correlations with other ADL scores (r < 0.2) indicated that different scores cover a different range of ADLs. The original two factor model could not be confirmed. A suggested four factor model distinguishing initiative and performance of basic and instrumental ADL demonstrated better indices of fit and higher correlations with corresponding scales.Conclusion: A four factor model of the IDDD can be used in dementia research for assessing initiative in and performance of basic and household activities of daily living. The findings suggest that ADL scales correlate only poorly and that further development of the IDDD is needed to cover a broader range of ADLs.


2016 ◽  
Vol 11 (2) ◽  
pp. 235-239 ◽  
Author(s):  
Kristie-Lee Taylor ◽  
Will G. Hopkins ◽  
Dale W. Chapman ◽  
John B. Cronin

The purpose of this study was to calculate the coefficients of variation in jump performance for individual participants in multiple trials over time to determine the extent to which there are real differences in the error of measurement between participants. The effect of training phase on measurement error was also investigated. Six subjects participated in a resistance-training intervention for 12 wk with mean power from a countermovement jump measured 6 d/wk. Using a mixed-model meta-analysis, differences between subjects, within-subject changes between training phases, and the mean error values during different phases of training were examined. Small, substantial factor differences of 1.11 were observed between subjects; however, the finding was unclear based on the width of the confidence limits. The mean error was clearly higher during overload training than baseline training, by a factor of ×/÷ 1.3 (confidence limits 1.0–1.6). The random factor representing the interaction between subjects and training phases revealed further substantial differences of ×/÷ 1.2 (1.1–1.3), indicating that on average, the error of measurement in some subjects changes more than in others when overload training is introduced. The results from this study provide the first indication that within-subject variability in performance is substantially different between training phases and, possibly, different between individuals. The implications of these findings for monitoring individuals and estimating sample size are discussed.


Sign in / Sign up

Export Citation Format

Share Document