scholarly journals Research on Load Disturbance Based Variable Speed PID Control and a Novel Denoising Method Based Effect Evaluation of HST for Agricultural Machinery

Agriculture ◽  
2021 ◽  
Vol 11 (10) ◽  
pp. 960
Author(s):  
Zhun Cheng ◽  
Zhixiong Lu

This paper aims to realize and improve the constant speed control performance of tractors with HST (Hydrostatic Transmission) variable speed units. To achieve this, based on the HST test bench of the tractor, we perform a verification test of the adjustable speed characteristics, a denoising filter test of the response signal, a test on the influence of the load disturbance on the adjustable speed characteristics and a PID-based constant speed performance detection test. The results of the verification test of the adjustable speed characteristics show that the theoretical value and actual value of the adjustable speed transmission characteristics of the HST used are essentially consistent with each other. The results of the test of the load disturbance’s influence on the adjustable speed characteristics show that the increase in load torque inhibits the HST output response. Therefore, the paper proposes and designs a PID-based closed-loop constant speed control system. The paper uses a step response test and a load disturbance test to research the control result of the constant speed system. Collecting and analyzing all test results, we find that the constant speed control based on PID has a very good result. The average error between the average HST output speed and the target speed set was 0.37%, and the average standard deviation of output speed was 1.18 rpm. In addition, the paper proposes a denoising method combing the empirical mode decomposition method and the Gaussian distribution determination. The method shows that the first two orders of the components of the HST response signal should be removed as noise. The paper uses the denoised signal and the partial least squares method to analyze the influencing factors of the constant speed control result. The analysis results show that the rate of change of load torque has the biggest influence on the stability of HST output speed, followed by the target value.

2015 ◽  
Vol 62 (3) ◽  
pp. 347-362 ◽  
Author(s):  
Farid Khayatzadeh ◽  
Jafar Ghafouri

Abstract This paper presents a development of a model of a set of multistage centrifugal electro pumps including two 4 stage stainless steel centrifugal pumps, each coupled to a 4 kW three-phase induction motor, connected to a hydraulic application running under two control strategies including constant speed and variable speed methods. Each pump provides 16 m3/hr flow rate and 58mwater head at BEP (Best Efficiency Point). Dynamicity of the model causes variations in all operational parameters of pumping system in any variation on consuming flow rate. Each electro pump has been driven with a variable frequency drive utilizing frequency control method for adjusting the rotational speed under a PID control regarding to match of pumping system operational point with the consumption point to save the energy. 83% energy saving is achieved by model in variable speed control strategy comparing to constant speed control strategy. MATLAB/SIMULINK software using ode45 solver and variable step size simulates this model.


2016 ◽  
Vol 63 (12) ◽  
pp. 7754-7764 ◽  
Author(s):  
Dan-Yong Li ◽  
Wen-Chuan Cai ◽  
Peng Li ◽  
Zi-Jun Jia ◽  
Hou-Jin Chen ◽  
...  

2015 ◽  
Vol 9 (2) ◽  
pp. 107-116 ◽  
Author(s):  
Shao‐Kai Tseng ◽  
Chih‐Chien Tseng ◽  
Tian‐Hua Liu ◽  
Jui‐Ling Chen

Sign in / Sign up

Export Citation Format

Share Document