scholarly journals Method Validation and Characterization of the Associated Uncertainty for Malondialdehyde Quantification in Exhaled Breath Condensate

Antioxidants ◽  
2021 ◽  
Vol 10 (11) ◽  
pp. 1661
Author(s):  
Maud Hemmendinger ◽  
Jean-Jacques Sauvain ◽  
Nancy B. Hopf ◽  
Pascal Wild ◽  
Guillaume Suárez ◽  
...  

There are several methods for quantifying malondialdehyde (MDA), an oxidative stress biomarker, in exhaled breath condensate (EBC). However, due to the very diluted nature of this biological matrix, a high variability is observed at low concentrations. We aimed to optimize a 2,4-dinitrophenylhydrazine-based method using liquid chromatography coupled to tandem mass spectrometry and characterize the uncertainty associated with this method. We investigated the following parameters for the method validation: calibration linearity, limit of detection (LOD), precision, recovery, and matrix effect. The results were used to identify the main sources of uncertainty and calculating the combined uncertainty. The applicability of this method was evaluated in an ongoing epidemiological study by analyzing 164 EBC samples collected from different professional groups in subway environments. The optimized method was sensitive (LOD: 70 pg/mL), precise (inter-day variation < 19%) and accurate (recovery range: 92–106.5%). The calculated analytical uncertainty was the highest at the LOQ level and reached 23%. Although the analytical uncertainty was high at low MDA concentrations, it was significantly lower than that the observed inter-individual variability. Hence, this method performs sufficiently well and can be recommended for future use in epidemiological researches relying on between-subject differences.

2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Yan Liang ◽  
Samantha M. Yeligar ◽  
Lou Ann S. Brown

Exhaled breath condensate (EBC) has been increasingly studied as a noninvasive research method for sampling the alveolar and airway space and is recognized as a promising source of biomarkers of lung diseases. Substances measured in EBC include oxidative stress and inflammatory mediators, such as arachidonic acid derivatives, reactive oxygen/nitrogen species, reduced and oxidized glutathione, and inflammatory cytokines. Although EBC has great potential as a source of biomarkers in many lung diseases, the low concentrations of compounds within the EBC present challenges in sample collection and analysis. Although EBC is viewed as a noninvasive method for sampling airway lining fluid (ALF), validation is necessary to confirm that EBC truly represents the ALF. Likewise, a dilution factor for the EBC is needed in order to compare across subjects and determine changes in the ALF. The aims of this paper are to address the characteristics of EBC; strategies to standardize EBC sample collection and review available analytical techniques for EBC analysis.


2019 ◽  
Vol 25 (1) ◽  
pp. 50-56 ◽  
Author(s):  
Fariba Pourkarim ◽  
Elaheh Rahimpour ◽  
Maryam Khoubnasabjafari ◽  
Vahid Jouyban-Gharamaleki ◽  
Abolghasem Jouyban

Background: In this research, an enhanced fluorimetric assay was developed for the direct monitoring of verapamil in exhaled breath condensate (EBC). The method is based on a binding–induced rigidity inside the sodium dodecyl sulfate (SDS) micelle which eliminate collisional quenching and vibrational modes responsible for non-radiative decay. This process produces an enhancement in the emission intensity of verapamil. Methods: Fluorescence intensity measurements were made at 15 ˚C on a FP-750 spectrofluorometer with maximum excitation and emission wavelengths of 280 nm and 310 nm, respectively. The important parameters influencing the analytical signal in experimental steps were investigated and optimized. The method was validated with considering of the linearity, recovery and limit of detection. Results: Under the optimized experimental conditions, the calibration graph was linear in the range of 0.02 − 12.0 µg.mL−1 of verapamil with a detection limit of 0.008 µg.mL–1. Conclusion: The proposed method was found to be suitable and accurate for the determination of verapamil and the validated method was successfully used for analysis of verapamil in EBC of patients receiving verapamil with the satisfactory results.


2018 ◽  
Vol 44 (3) ◽  
pp. 256-266 ◽  
Author(s):  
Don R. Bergfelt ◽  
John Lippolis ◽  
Michel Vandenplas ◽  
Sydney Davis ◽  
Blake A. Miller ◽  
...  

2020 ◽  
Vol 16 (7) ◽  
pp. 872-879
Author(s):  
Samin Hamidi

Background: Abuse of drugs is associated with several medical, forensic, toxicology and social challenges. “Drugs of abuse” testing is therefore an important issue. Objective: We propose a simple CE-based method for the quantification of amphetamine, codeine and morphine after direct injection of Exhaled Breath Condensate (EBC) by the aid of simple stacking mode and an off-line pre-concentration method. Methods: Using graphene oxide adsorbents, amphetamine, codeine and morphine were extracted from EBC in order to eliminate the proteins and other interferences. In addition to off-line method, an online stacking mode was applied to improve the analytical signal obtained from the instrument. Results: The validation parameters were experimented on the developed method based on the FDA guideline over concentration ranges of 12.5-100, 30-500 and 10-1250 ng/mL associated with amphetamine, codeine and morphine, respectively. Small volumes (around 100 μL) of EBC were collected using a lab-made setup and successfully analyzed using the proposed method where precisions and accuracies (within day and between days) were in accordance with the guideline (recommended less than 15 % for biological samples). The recovery tests were used to evaluate the matrix effect and data (94 to 105 %) showed that the proposed method can be applied in different EBC matrix samplings of subjects. Conclusion: The proposed method is superior for simultaneous determination of amphetamine, codeine and morphine over chromatographic analyses because it is fast and consumes fewer chemicals, with no derivatization step.


2020 ◽  
Vol 16 (8) ◽  
pp. 1032-1040
Author(s):  
Laleh Samini ◽  
Maryam Khoubnasabjafari ◽  
Mohamad M. Alimorad ◽  
Vahid Jouyban-Gharamaleki ◽  
Hak-Kim Chan ◽  
...  

Background: Analysis of drug concentrations in biological fluids is required in clinical sciences for various purposes. Among other biological samples, exhaled breath condensate (EBC) is a potential sample for follow up of drug concentrations. Methods: A dispersive liquid-liquid microextraction (DLLME) procedure followed by a validated liquid chromatography method was employed for the determination of budesonide (BDS) in EBC samples collected using a homemade setup. EBC is a non-invasive biological sample with possible applications for monitoring drug concentrations. The proposed analytical method is validated according to the FDA guidelines using EBC-spiked samples. Its applicability is tested on EBC samples collected from healthy volunteers receiving a single puff of BDS. Results: The best DLLME conditions involved the use of methanol (1 mL) as a disperser solvent, chloroform (200 μL) as an extraction solvent, and centrifugation rate of 3500 rpm for 5 minutes. The method was validated over a concentration range of 21-210 μg·L-1 in EBC. Inter- and intra-day precisions were less than 10% where the acceptable levels are less than 20%. The validated method was successfully applied for the determination of BDS in EBC samples. Conclusion: The findings of this study indicate that the developed method can be used for the extraction and quantification of BDS in EBC samples using a low cost method.


2019 ◽  
Vol 15 (5) ◽  
pp. 535-541 ◽  
Author(s):  
Fariba Pourkarim ◽  
Ali Shayanfar ◽  
Maryam Khoubnasabjafari ◽  
Fariborz Akbarzadeh ◽  
Sanaz Sajedi-Amin ◽  
...  

Background:Developing a simple analysis method for quantification of drug concentration is one of the essential issues in pharmacokinetic and therapeutic drug monitoring studies.Objective:A fast and reliable dispersive liquid-liquid microextraction procedure was employed for preconcentration of verapamil in exhaled breath condensate (EBC) samples and this was followed by the determination with high-performance liquid chromatography-ultraviolet detection.Methods:A reverse-phase high-performance liquid chromatography (RP-HPLC) combined with a dispersive liquid-liquid microextraction method (DLLME) was applied for quantification of verapamil in the EBC samples. The developed method was validated according to FDA guidelines.Results:Under the optimum conditions, the method provided a linear range between 0.07 and 0.8 µg.mL-1 with a coefficient of determination of 0.998. The intra- and inter-day relative standard deviation and relative error values of the method were below 15%, which indicated good precision and accuracy. The proposed method was successfully applied for the analysis of verapamil in two real samples with concentrations of 0.07 and 0.09 µg.mL-1.Conclusion:The established HPLC-UV-DLLME method could be applied for the analysis of verapamil in human EBC samples.


2019 ◽  
Vol 75 (2) ◽  
pp. 65-69 ◽  
Author(s):  
Chieh-Ming Wu ◽  
Anna Adetona ◽  
Chi (Chuck) Song ◽  
Luke Naeher ◽  
Olorunfemi Adetona

Sign in / Sign up

Export Citation Format

Share Document