scholarly journals Heat Pump Bridge Analysis Using the Modified Energy Transfer Diagram

Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 137
Author(s):  
Florian Schlosser ◽  
Heinrich Wiebe ◽  
Timothy G. Walmsley ◽  
Martin J. Atkins ◽  
Michael R. W. Walmsley ◽  
...  

Heat pumps are the key technology to decarbonise thermal processes by upgrading industrial surplus heat using renewable electricity. Existing insight-based integration methods refer to the idealised Grand Composite Curve requiring the full exploitation of heat recovery potential but leave the question of how to deal with technical or economic limitations unanswered. In this work, a novel Heat Pump Bridge Analysis (HPBA) is introduced for practically targeting technical and economic heat pump potential by applying Coefficient of Performance curves into the Modified Energy Transfer Diagram (METD). Removing cross-Pinch violations and operating heat exchangers at minimum approach temperatures by combined application of Bridge Analysis increases the heat recovery rate and reduce the temperature lift to be pumped at the same time. The insight-based METD allows the individual matching of heat surpluses and deficits of individual streams with the capabilities and performance of different market-available heat pump concepts. For an illustrative example, the presented modifications based on HPBA increase the economically viable share of the technical heat pump potential from 61% to 79%.

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2273
Author(s):  
Seung-Hoon Park ◽  
Yong-Sung Jang ◽  
Eui-Jong Kim

The earth provides a vast resource of groundwater from aquifers a few meters beneath the surface. Thus, buildings that use underground space must be equipped with dewatering wells to drain the permeated groundwater to the sewage pipelines to ensure the structural stability of the building. Although the inflowing groundwater temperatures and flow rates are stable enough for groundwater to be used as an energy source, 79% of the permeated groundwater is discarded through the sewers, generating significant sewerage expenses. This study introduced a novel heat exchanger module to utilize the permeated groundwater as an unused energy source using heat pumps, and the performance of the system was evaluated by TRNSYS simulations. First, the sizing of the unit heat exchanger module was proposed according to the mean inflow rate of the permeated groundwater. Second, the heat pump system was configured using multiple modules in the source-side loop. Finally, the performance of the proposed heat pump system was compared with that of a conventional air source heat pump using realistic load and temperature profiles. This preliminary study demonstrated interesting performance results, with a coefficient of performance for heating that was higher than that of a conventional heat pump system by 0.79. The results show the potential utilization of the systems for a construction project requiring large-scale underground spaces, where abundant groundwater is available.


2012 ◽  
Vol 9 (2) ◽  
pp. 65
Author(s):  
Alhassan Salami Tijani ◽  
Nazri Mohammed ◽  
Werner Witt

Industrial heat pumps are heat-recovery systems that allow the temperature ofwaste-heat stream to be increased to a higher, more efficient temperature. Consequently, heat pumps can improve energy efficiency in industrial processes as well as energy savings when conventional passive-heat recovery is not possible. In this paper, possible ways of saving energy in the chemical industry are considered, the objective is to reduce the primary energy (such as coal) consumption of power plant. Particularly the thermodynamic analyses ofintegrating backpressure turbine ofa power plant with distillation units have been considered. Some practical examples such as conventional distillation unit and heat pump are used as a means of reducing primary energy consumption with tangible indications of energy savings. The heat pump distillation is operated via electrical power from the power plant. The exergy efficiency ofthe primary fuel is calculated for different operating range ofthe heat pump distillation. This is then compared with a conventional distillation unit that depends on saturated steam from a power plant as the source of energy. The results obtained show that heat pump distillation is an economic way to save energy if the temperaturedifference between the overhead and the bottom is small. Based on the result, the energy saved by the application of a heat pump distillation is improved compared to conventional distillation unit.


Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1576
Author(s):  
Piotr Jadwiszczak ◽  
Jakub Jurasz ◽  
Bartosz Kaźmierczak ◽  
Elżbieta Niemierka ◽  
Wandong Zheng

Heating and cooling sectors contribute to approximately 50% of energy consumption in the European Union. Considering the fact that heating is mostly based on fossil fuels, it is then evident that its decarbonization is one of the crucial tasks for achieving climate change prevention goals. At the same time, electricity sectors across the globe are undergoing a rapid transformation in order to accommodate the growing capacities of non-dispatchable solar and wind generators. One of the proposed solutions to achieve heating sector decarbonization and non-dispatchable generators power system integration is sector coupling, where heat pumps are perceived as a perfect fit. Air source heat pumps enable a rapid improvement in local air quality by replacing conventional heating sources, but at the same time, they put additional stress on the power system. The emissions associated with heat pump operation are a combination of power system energy mix, weather conditions and heat pump technology. Taking the above into consideration, this paper presents an approach to estimate which of the mentioned factors has the highest impact on heat pump emissions. Due to low air quality during the heating season, undergoing a power system transformation (with a relatively low share of renewables) in a case study located in Poland is considered. The results of the conducted analysis revealed that for a scenario where an air-to-water (A/W) heat pump is supposed to cover space and domestic hot water load, its CO2 emissions are shaped by country-specific energy mix (55.2%), heat pump technology (coefficient of performance) (33.9%) and, to a lesser extent, by changing climate (10.9%). The outcome of this paper can be used by policy makers in designing decarbonization strategies and funding distribution.


2013 ◽  
Vol 805-806 ◽  
pp. 645-648
Author(s):  
Wei Xiu Shi ◽  
Li Sheng Pan

Under the situation of energy crisis, air source heat pumps are paid more attention recently. In order to save energy, the feasibility and performance of air source heat pump are studied by experiment, and variation laws of exhaust temperature, evaporator outlet temperature and outlet presser of compressor were analyzed in this paper. Air source heat pump apparatus were set up and the experiment was during 10°C, 20°C, 30°C and 40°C. The results were as follows: exhaust temperature of compressor increases gradually with the increase of tank temperature, but the temperature difference between exhaust temperature of compressor and tank temperature becomes little; temperature difference in evaporator decreases; Compressor outlet pressure increases obviously.


Author(s):  
Srinivas Vanapalli ◽  
M. E. H. Tijani ◽  
Simon Spoelstra

Domestic heating contributes to a significant amount of energy usage in the Netherlands. Due to scare energy resources, attention to develop new and efficient technologies is increasing. At ECN, a burner driven heat pump employing thermoacoustic technology is being developed for possible applications in households and offices. The desired temperature lift is from 10 °C to 80 °C. As a first step the heat pump is driven by a linear motor. Measurements and performance analysis of the heat pump are presented in this paper. The heat pump has a coefficient of performance which is the ratio of heat produced to the work input of 1.38 when operating between 10 °C to 80 °C. The performance relative to maximum possible Carnot value is 26.5%.


Author(s):  
Giulio Vialetto ◽  
Marco Noro ◽  
Masoud Rokni

In this paper, a new heat recovery for a microcogeneration system based on solid oxide fuel cell and air source heat pump (HP) is presented with the main goal of improving efficiency on energy conversion for a residential building. The novelty of the research work is that exhaust gases after the fuel cell are first used to heat water for heating/domestic water and then mixed with the external air to feed the evaporator of the HP with the aim of increasing energy efficiency of the latter. This system configuration decreases the possibility of freezing of the evaporator as well, which is one of the drawbacks for air source HP in Nordic climates. A parametric analysis of the system is developed by performing simulations varying the external air temperature, air humidity, and fuel cell nominal power. Coefficient of performance (COP) can increase more than 100% when fuel cell electric power is close to its nominal (50 kW), and/or inlet air has a high relative humidity (RH) (close to 100%). Instead, the effect of mixing the exhausted gases with air may be negative (up to −25%) when fuel cell electric power is 20 kW and inlet air has 25% RH. Thermodynamic analysis is carried out to prove energy advantage of such a solution with respect to a traditional one, resulting to be between 39% and 44% in terms of primary energy. The results show that the performance of the air source HP increases considerably during cold season for climates with high RH and for users with high electric power demand.


Author(s):  
Mohammad Omar Temori ◽  
František Vranay

In this work, a mini review of heat pumps is presented. The work is intended to introduce a technology that can be used to income energy from the natural environment and thus reduce electricity consumption for heating and cooling. A heat pump is a mechanical device that transfers heat from one environmental compartment to another, typically against a temperature gradient (i.e. from cool to hot). In order to do this, an energy input is required: this may be mechanical, electrical or thermal energy. In most modern heat pumps, electrical energy powers a compressor, which drives a compression - expansion cycle of refrigerant fluid between two heat exchanges: a cold evaporator and a warm condenser. The efficiency or coefficient of performance (COP), of a heat pump is defined as the thermal output divided by the primary energy (electricity) input. The COP decreases as the temperature difference between the cool heat source and the warm heat sink increases. An efficient ground source heat pump (GSHP) may achieve a COP of around 4. Heat pumps are ideal for exploiting low-temperature environmental heat sources: the air, surface waters or the ground. They can deliver significant environmental (CO2) and cost savings.


The chapter is devoted to design and performance of adsorptive heat pumps. In the first sub-division, state-of-the-art of the adsorptive heat pumping is analyzed. It involves analysing operating principle of adsorptive heat pumps, comparing of the properties of adsorbents used, bed specifications, and operating conditions. Original construction of the adsorptive heat pump is designed by authors for independent heat supply systems or hot water supply of buildings and other structures for various purposes. The composites ‘silica gel – sodium sulphate' or ‘silica gel – sodium acetate' were used as adsorbents. Discharging was performed in a daytime, when heat pump supplied heating system with water warmed to 45 – 35°C. The regeneration mode proceeded at night from 0.00 to 8.00 a.m. Efficiency of suggested adsorptive heat pump is estimated by two methods: as ratio of adsorption heat to sum of desorption heat and external heat supplied to sorbent during its heating up to regeneration temperature (coefficient of performance of cycle) and as ratio of heat of adsorption to heat supplied by solar collector (net coefficient of performance). Suggested heat pump coefficients of energy performance of cycle are stated to be 2.084 when composite ‘silica gel – sodium sulphate' used and 2.021 when ‘silica gel – sodium acetate' used. Seasonal dependence of net coefficient energy performance for suggested adsorptive heat pump based on composites ‘silica gel – sodium sulphate' and ‘silica gel – sodium acetate' is revealed. Correlation of coefficients of energy performance of adsorptive heat pump and composite sorbents properties (sorption capacity and regeneration temperature) is stated. Insignificant decreasing of coefficients of energy performance when ‘silica gel – sodium acetate' used is explained by lower sorptive capacity as compared to ‘silica gel – sodium sulphate'. Suggested heat pump application perspectives are shown for heat supply systems to result from traditional energy sources independence and environmental advantages. Adsorptive heat pumps development challenges, major limitations for commercialization of adsorptive heat pumping, and requirements to ongoing innovations are analysed. The present chapter can be useful for energy efficient decentralized heat supply systems based on adsorptive heat pump unit.


Energies ◽  
2020 ◽  
Vol 13 (3) ◽  
pp. 635 ◽  
Author(s):  
Limei Gai ◽  
Petar Sabev Varbanov ◽  
Timothy Gordon Walmsley ◽  
Jiří Jaromír Klemeš

To date, research on heat pumps (HP) has mainly focused on vapour compression heat pumps (VCHP), transcritical heat pumps (TCHP), absorption heat pumps, and their heat integration with processes. Few studies have considered the Joule cycle heat pump (JCHP), which raises several questions. What are the characteristics and specifics of these different heat pumps? How are they different when they integrate with the processes? For different processes, which heat pump is more appropriate? To address these questions, the performance and integration of different types of heat pumps with various processes have been studied through Pinch Methodology. The results show that different heat pumps have their own optimal application range. The new JCHP is suitable for processes in which the temperature changes of source and sink are both massive. The VCHP is more suitable for the source and sink temperatures, which are near-constant. The TCHP is more suitable for sources with small temperature changes and sinks with large temperature changes. This study develops an approach that provides guidance for the selection of heat pumps by applying Process Integration to various combinations of heat pump types and processes. It is shown that the correct choice of heat pump type for each application is of utmost importance, as the Coefficient of Performance can be improved by up to an order of magnitude. By recovering and upgrading process waste heat, heat pumps can save 15–78% of the hot utility depending on the specific process.


Energies ◽  
2019 ◽  
Vol 12 (22) ◽  
pp. 4313 ◽  
Author(s):  
Boahen ◽  
Choi

The use of cascade heat pumps for hot water generation has gained much attention in recent times. The big question that has attracted much research interest is how to enhance the performance and energy saving potential of these cascade heat pumps. This study therefore proposed a new cycle to enhance performance of the cascade heat pump by adopting an auxiliary heat exchanger (AHX) in desuperheater, heater and parallel positions at the low stage (LS) side. The new cascade cycle with AHX in desuperheater position was found to have better performance than that with AHX at heater and parallel positions. Compared to the conventional cycle, heating capacity and coefficient of performance (COP) of the new cascade cycle with AHX in desuperheater position increased up to 7.4% and 14.9% respectively.


Sign in / Sign up

Export Citation Format

Share Document