scholarly journals 5-Year Clinical and Radiographic Results of the Direct Anterior Approach for Total Hip Arthroplasty Using a Collared Cementless Femoral Short-Stem Prosthesis

2022 ◽  
Vol 11 (2) ◽  
pp. 346
Author(s):  
Ali Darwich ◽  
Kim Pankert ◽  
Andreas Ottersbach ◽  
Marcel Betsch ◽  
Sascha Gravius ◽  
...  

The aim of this study was to investigate the radiological and clinical outcome of the direct anterior approach (DAA) in total hip arthroplasty (THA) using a collared cementless femoral short-stem. This retrospective study included 124 patients with 135 THAs operated from 2014 to 2016 using a collared cementless triple tapered hydroxyapatite-coated femoral short-stem (AMIStem H Collared®, Medacta International, Castel San Pietro, Switzerland) implanted with a DAA. Follow-up was performed at three months, 12 months, and five years. Clinical outcome was assessed using the hip osteoarthritis outcome score (HOOS) and radiological analysis was done using conventional radiographs, which included evaluation of the femur morphology based on Dorr classification, of radiolucencies based on the Gruen zone classification and of stem subsidence. The mean age was 67.7 ± 11.3 years and the mean body mass index (BMI) was 27.4 ± 4.4 kg/m2. The stem survival rate at five years was 99.1% with one revision due to recurrent dislocations. Mean HOOS score improved from 40.9 ± 18.3 preoperatively to 81.5 ± 19.7 at three months, 89.3 ± 10.9 at 12 months, and 89.0 ± 14.0 at five years (all with p < 0.001). No significant correlations were found between age, femoral bone morphology, BMI and HOOS, and the appearance of relevant radiolucencies.

2015 ◽  
Vol 9 (1) ◽  
pp. 157-162 ◽  
Author(s):  
Sachiyuki Tsukada ◽  
Motohiro Wakui

Objective: The aim of the study was to compare the dislocation rate between total hip arthroplasty (THA) via direct anterior approach (DAA) and via posterior approach (PA). Methods: We compared a consecutive series of 139 THAs via DAA with 177 THAs via PA. All study patients received ceramic-on-ceramic bearing surfaces and similar uncemented prostheses. Dislocation-free survival after THA was estimated using the Kaplan–Meier survival method and compared between groups using the log-rank test. Results: In the DAA group, none of 139 hips experienced dislocations in five-year-average follow-up. In the PA group, seven hips experienced dislocations among 177 hips (4 %). The dislocation was significantly less in the DAA group compared to the PA group (p = 0.033). Conclusion: The dislocation rate of THA via DAA was significantly less than that of THA via PA.


2020 ◽  
Vol 04 (01) ◽  
pp. 033-037
Author(s):  
Samantha Andrews ◽  
Gregory J. Harbison ◽  
Ian Hasegawa ◽  
Emily Unebasami ◽  
Cass Nakasone

AbstractThe cementless, tapered wedge, short femoral stem implant is commonly used in direct anterior approach (DAA) total hip arthroplasty (THA). The lack of access and visualization, however, may increase the risk of perioperative fracture and early failure. Therefore, the current study examined perioperative complications and 2-year implant survivorship following DAA THA performed using a fracture table and short, tapered wedge femoral stem. A retrospective analysis was conducted on patients having undergone DAA THA with a cementless, tapered wedge, short femoral stem. Perioperative fractures were noted and survivorship was determined by the incidence of revision surgery within a minimum 2-year follow-up period. A total 366 consecutive patients (441 hips) were identified in the cohort. Four patients (6 hips; 1.4%) were lost to follow-up and three patients died from unrelated causes. Average follow-up time for the remaining 359 patients (435 hips) was 32.9 ± 10.2 months. There were no intraoperative factures but three perioperative fractures within two weeks. Aseptic loosening occurred in one stem at 13 months, resulting in a 99.1% survival rate with a mean survival time of 23.8 ± 0.1 months (95% confidence interval: 23.6–24.0 months). The use of a short, tapered wedge femoral stem and a fracture table for DAA THA resulted in 0.7% periprosthetic fractures and only one aseptic loosening within 2 years. These results suggest that proper femoral exposure with the use of a fracture table and a short, tapered wedge femoral stem does not appear to increase the risk of periprosthetic femoral fracture.


Author(s):  
Barbara Favier ◽  
Nathalie van Beek ◽  
Mike Tengrootenhuysen

AbstractThe aim of this study was to assess the applicability and ability of preoperative templating to restore femoral offset and hip length with a calcar-guided short-stem implant design in total hip arthroplasty through the direct anterior approach. Preoperative measurements were performed of femoral offset, hip length, and stem size and compared with the perioperative placed prosthesis in 100 patients undergoing primary total hip replacement through direct anterior approach. Additionally, the pre- and postoperative femoral offset and hip length were compared to evaluate the ability to restore the offset and hip length with this kind of femoral short stem. With an acceptance of 1 size difference pre- and postoperatively, a 94% accuracy of predicting the size of the calcar-guided short stem was achieved with templating. Femoral offset was within means of 5 mm in 82.2% of the patients. Postoperative hip length was within 6 mm in 90% of the patients compared with the preoperative length.The use of preoperative templating for total hip arthroplasty with calcar-guided short-stem implants was proven to be a useful tool to predict the definite implanted size of the femoral prosthesis. Our results show that this new stem design does not significantly differ from previous reported outcomes with other stem designs and is competent to restore the femoral offset and hip length within clinical acceptable range. Level of evidence Level 3 retrospective case study.


2018 ◽  
Vol 28 (6) ◽  
pp. 591-598 ◽  
Author(s):  
Christophe Tissot ◽  
Matthias Vautrin ◽  
Anais Luyet ◽  
Olivier Borens

Introduction: Compared to a lateral or posterior approach (PA), the direct anterior approach (DAA) does permit a better muscle preservation for total hip arthroplasty (THA). However, there is concern whether this advantage come with increased wound complication and infection leading to reoperation or sometimes major procedures. Method: We retrospectively reviewed all patients who underwent primary THA through the PA between January 2009 and April 2013 ( n = 796) and through the DAA between January 2011 and April 2013 ( n = 399) at our institution with a minimum of 2 years follow up regarding all wound complications and all infections. Results: Of the 796 patients in the PA group, there were 6 wound complications leading to reoperation and 6 infections; 4 early and 2 delayed onset. Among the infected cases, one was obese (body mass index [BMI] >30 kg/m2). Two procedures were teaching-based. Of the 399 patients in the DAA group, there were three dehiscences leading to reoperation, two of which were in obese patients. 6 infections were also found; 4 with early and 2 with delayed onset. Of the infected cases, three were obese. 4 procedures were teaching-based. Conclusion: In our series of patients undergoing THA, the DAA did not increase the rates of either wound complications leading to reoperation nor early or delayed infection compared to the PA.


2021 ◽  
Vol 103-B (7 Supple B) ◽  
pp. 38-45
Author(s):  
John V. Horberg ◽  
Benjamin R. Coobs ◽  
Aneel K. Jiwanlal ◽  
Christopher J. Betzle ◽  
Susan G. Capps ◽  
...  

Aims Use of the direct anterior approach (DAA) for total hip arthroplasty (THA) has increased in recent years due to proposed benefits, including a lower risk of dislocation and improved early functional recovery. This study investigates the dislocation rate in a non-selective, consecutive cohort undergoing THA via the DAA without any exclusion or bias in patient selection based on habitus, deformity, age, sex, or fixation method. Methods We retrospectively reviewed all patients undergoing THA via the DAA between 2011 and 2017 at our institution. Primary outcome was dislocation at minimum two-year follow-up. Patients were stratified by demographic details and risk factors for dislocation, and an in-depth analysis of dislocations was performed. Results A total of 2,831 hips in 2,205 patients were included. Mean age was 64.9 years (24 to 96), mean BMI was 29.2 kg/m2 (15.1 to 53.8), and 1,595 patients (56.3%) were female. There were 11 dislocations within one year (0.38%) and 13 total dislocations at terminal follow-up (0.46%). Five dislocations required revision. The dislocation rate for surgeons who had completed their learning curve was 0.15% compared to 1.14% in those who had not. The cumulative periprosthetic infection and fracture rates were 0.53% and 0.67%, respectively. Conclusion In a non-selective, consecutive cohort of patients undergoing THA via the DAA, the risk of dislocation is low, even among patients with risk factors for instability. Our data further suggest that the DAA can be safely used in all hip arthroplasty patients without an increased risk of wound complications, fracture, infection, or revision. The inclusion of seven surgeons increases the generalizability of these results. Cite this article: Bone Joint J 2021;103-B(7 Supple B):38–45.


2020 ◽  
Vol 30 (2_suppl) ◽  
pp. 52-58
Author(s):  
Michela Saracco ◽  
Giulio Maccauro ◽  
Andrea Urbani ◽  
Domenico Ciavardelli ◽  
Silvia Persichilli ◽  
...  

Introduction: The aim of this study is to evaluate clinical, radiographic and laboratory results of ceramic-on-metal (CoM) (hybrid hard bearing) in total hip arthroplasty (THA), associated with a short stem implant. Methods: From a cohort of 37 patients suffering from primary or secondary hip osteoarthritis who underwent THA using CoM bearing, 19 were suitable for this study. All procedures were performed by the same surgeon using a posterior-lateral approach. All patients were compared clinically using the Harris Hip Score (HHS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), visual analogue scale (VAS), 12-item Short Form Health Survey (SF12F/M), and radiographically (offset, CD angle, limb length discrepancy, cup inclination and anteversion, subsidence, osseointegration, heterotopic ossification). Blood samples were collected in order to evaluate chromium (Cr) and cobalt (Co) ions level. Radiographic evaluations were carried out by 3 different blinded surgeons. A statistical analysis was performed. Results: At a mean follow-up of 97 (73–125) months all implanted stems were well-positioned and osseointegrated. Clear improvements were observed for clinical scores comparing preoperative and postoperative values. Radiographic evaluation showed a good ability to restore proper articular geometry. Cr ion analysis revealed values below the safety threshold except for 1 case. Serum levels of Co were below the threshold in all patients. There was a statistically significant correlation only between Cr metal ions and length of follow-up. Conclusions: CoM bearing has proven to be reliable and safe at a mean 8-year follow-up for patients in whom the components were correctly implanted. The rise of blood metal ions was minimal and involved neither systemic or local toxicity nor influenced clinical results.


Sign in / Sign up

Export Citation Format

Share Document