scholarly journals Aluminium Alloy Foam Modelling and Prediction of Elastic Properties Using X-ray Microcomputed Tomography

Metals ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 925
Author(s):  
Diogo Heitor ◽  
Isabel Duarte ◽  
João Dias-de-Oliveira

X-ray microcomputed tomography has been gaining relevance in the field of cellular materials to characterize materials and analyse their microstructure. So, here, it was used together with finite element modelling to develop numerical models to estimate the effective properties (Young’s modulus) of aluminium alloy foams and evaluate the effects of processing on the results. A manual global thresholding technique using the mass as a quality indicator was used. The models were reconstructed (Marching Cubes 33), then simplified and analysed in terms of mass and shape maintenance (Hausdorff distance algorithm) and face quality. Two simplification procedures were evaluated, with and without small structural imperfections, to evaluate the impact of the procedures on the results. Results demonstrate that the developed procedures are good at minimizing changes in mass and shape of the geometries while providing good face quality, i.e., face aspect ratio. The models are also shown to be able to predict the effective properties of metallic foams in accordance with the findings of other researchers. In addition, the process of obtaining the models and the presence of small structural imperfections were shown to have a great impact on the results.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Can Gökgöl ◽  
Yasushi Ueki ◽  
Daniel Abler ◽  
Nicolas Diehm ◽  
Rolf P. Engelberger ◽  
...  

AbstractThe hemodynamic behavior following endovascular treatment of patients with peripheral arterial disease plays a significant role on the occurrence of restenosis in femoro-popliteal (FP) arteries. The atheroprone flow conditions that are generally accepted to promote restenosis can be calculated by computational fluid dynamics (CFD) analyses, and these results can be used to assess individualized treatment outcomes. However, the impact of endovascular therapy on the flow behaviors of FP arteries are still poorly understood, as the imaging modalities used in existing numerical works (X-ray angiography, computed tomography angiography) are unable to accurately represent the post-treatment arterial geometry due to their low resolutions. Therefore, this study proposes a new algorithm that combines intra-arterial lumen geometry obtained from high-resolution optical coherence tomography (OCT) images with centerlines generated from X-ray images to reconstruct the FP artery with an in-plane resolution of 10 µm. This superior accuracy allows modeling characteristic geometrical structures, such as angioplasty-induced arterial dissections, that are too small to be reconstructed with other imaging modalities. The framework is applied on the clinical data of patients treated either with only-percutaneous transluminal angioplasty (PTA) (n = 4) or PTA followed by stenting (n = 4). Based on the generated models, PTA was found to cause numerous arterial dissections, covering approximately 10% of the total surface area of the lumen, whereas no dissections were identified in the stented arteries. CFD simulations were performed to investigate the hemodynamic conditions before and after treatment. Regardless of the treatment method, the areas affected by low time-averaged wall shear stress (< 0.5 Pa) were significantly higher (p < 0.05) following endovascular therapy (pre-PTA: 0.95 ± 0.59 cm2; post-PTA: 2.10 ± 1.09cm2; post-stent: 3.10 ± 0.98 cm2). There were no statistical differences between the PTA and the stent groups. However, within the PTA group, adverse hemodynamics were mainly concentrated at regions created by arterial dissections, which may negatively impact the outcomes of a leave-nothing-behind strategy. These observations show that OCT-based numerical models have great potential to guide clinicians regarding the optimal treatment approach.


Author(s):  
Mohamed Abdelhamid ◽  
Aleksander Czekanski

Cellular materials are found extensively in nature, such as wood, honeycomb, butterfly wings, and foam-like structures like trabecular bone and sponge. This class of materials proves to be structurally efficient by combining low weight with superior mechanical properties. Recent studies have shown that there are coupling relations between the mechanical properties of cellular materials and their relative density. Due to its favorable stretching‐dominated behavior, continuum models of the octet‐truss were developed to describe its effective mechanical properties. However, previous studies were only performed for the cubic symmetry case, where the lattice angle θ=45 deg. In this work, we study the impact of the lattice angle on the effective properties of the octet-truss: namely, the relative density, effective stiffness, and effective strength. The relative density formula is extended to account for different lattice angles up to a higher-order of approximation. Tensor transformations are utilized to obtain relations of the effective elastic and shear moduli, and Poisson's ratio at different lattice angles. Analytical formulas are developed to obtain the loading direction and value of the maximum and minimum specific elastic moduli at different lattice angles. In addition, tridimensional polar representations of the macroscopic strength of the octet‐truss are analyzed for different lattice angles. Finally, collapse surfaces for plastic yielding and elastic buckling are investigated for different loading combinations at different lattice angles. It has been found that lattice angles lower than 45 deg result in higher maximum values of specific effective elastic moduli, shear moduli, and strength.


2014 ◽  
Vol 49 (8) ◽  
pp. 592-606 ◽  
Author(s):  
Charles Betts ◽  
Daniel Balint ◽  
Junyi Lee ◽  
Jianguo Lin ◽  
Peter Lee

Microtensile testing was used to determine the mechanical properties of individual aluminium alloy foam struts. Finite element modelling of as-tested struts was carried out using X-ray microtomography scans of the undeformed struts to define the geometry. Strut deformation was described by continuum viscoplastic damage constitutive equations calibrated by microtensile test data of the aluminium alloy in its optimally aged condition. The as-tested strut finite element model was used to develop a procedure that compensates for the effect of grip slippage inherent in the microtensile testing of metal foam struts, which results in a considerable reduction in observed elastic stiffness compared to the typical value of 70 GPa for aluminium alloys. The calibrated constitutive equations were then implemented in finite element models of sandwich panels with the aluminium metal foam as its core material. The finite element models were used in simulations of cases of low energy impact to represent tool drop conditions in order to investigate the suitability of new wing skin designs using metal foam core sandwich panels. An optimal strut aspect ratio was identified through simulation that provides the greatest energy absorption per unit mass while ensuring core damage is accurately reflected by facesheet deformation, which is necessary for detection and repair.


2021 ◽  
Author(s):  
Sascha Senck ◽  
Michael Happl ◽  
Michael Scheerer ◽  
Jonathan Glinz ◽  
Thomas Reiter ◽  
...  

Author(s):  
Halit Dogan ◽  
Md Mahbub Alam ◽  
Navid Asadizanjani ◽  
Sina Shahbazmohamadi ◽  
Domenic Forte ◽  
...  

Abstract X-ray tomography is a promising technique that can provide micron level, internal structure, and three dimensional (3D) information of an integrated circuit (IC) component without the need for serial sectioning or decapsulation. This is especially useful for counterfeit IC detection as demonstrated by recent work. Although the components remain physically intact during tomography, the effect of radiation on the electrical functionality is not yet fully investigated. In this paper we analyze the impact of X-ray tomography on the reliability of ICs with different fabrication technologies. We perform a 3D imaging using an advanced X-ray machine on Intel flash memories, Macronix flash memories, Xilinx Spartan 3 and Spartan 6 FPGAs. Electrical functionalities are then tested in a systematic procedure after each round of tomography to estimate the impact of X-ray on Flash erase time, read margin, and program operation, and the frequencies of ring oscillators in the FPGAs. A major finding is that erase times for flash memories of older technology are significantly degraded when exposed to tomography, eventually resulting in failure. However, the flash and Xilinx FPGAs of newer technologies seem less sensitive to tomography, as only minor degradations are observed. Further, we did not identify permanent failures for any chips in the time needed to perform tomography for counterfeit detection (approximately 2 hours).


2012 ◽  
Vol 746 (1) ◽  
pp. L10 ◽  
Author(s):  
Joshua C. Dolence ◽  
Charles F. Gammie ◽  
Hotaka Shiokawa ◽  
Scott C. Noble

2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Matthew G. Hanson ◽  
Barry Chan

Abstract Background Symptomatic pericardial effusion (PCE) presents with non-specific features and are often missed on the initial physical exam, chest X-ray (CXR), and electrocardiogram (ECG). In extreme cases, misdiagnosis can evolve into decompensated cardiac tamponade, a life-threatening obstructive shock. The purpose of this study is to evaluate the impact of point-of-care ultrasound (POCUS) on the diagnosis and therapeutic intervention of clinically significant PCE. Methods In a retrospective chart review, we looked at all patients between 2002 and 2018 at a major Canadian academic hospital who had a pericardiocentesis for clinically significant PCE. We extracted the rate of presenting complaints, physical exam findings, X-ray findings, ECG findings, time-to-diagnosis, and time-to-pericardiocentesis and how these were impacted by POCUS. Results The most common presenting symptom was dyspnea (64%) and the average systolic blood pressure (SBP) was 120 mmHg. 86% of people presenting had an effusion > 1 cm, and 89% were circumferential on departmental echocardiogram (ECHO) with 64% having evidence of right atrial systolic collapse and 58% with early diastolic right ventricular collapse. The average time-to-diagnosis with POCUS was 5.9 h compared to > 12 h with other imaging including departmental ECHO. Those who had the PCE identified by POCUS had an average time-to-pericardiocentesis of 28.1 h compared to > 48 h with other diagnostic modalities. Conclusion POCUS expedites the diagnosis of symptomatic PCE given its non-specific clinical findings which, in turn, may accelerate the time-to-intervention.


Polymers ◽  
2021 ◽  
Vol 13 (13) ◽  
pp. 2212
Author(s):  
Worawat Poltabtim ◽  
Ekachai Wimolmala ◽  
Teerasak Markpin ◽  
Narongrit Sombatsompop ◽  
Vichai Rosarpitak ◽  
...  

The potential utilization of wood/polyvinyl chloride (WPVC) composites containing an X-ray protective filler, namely bismuth oxide (Bi2O3) particles, was investigated as novel, safe, and environmentally friendly X-ray shielding materials. The wood and Bi2O3 contents used in this work varied from 20 to 40 parts per hundred parts of PVC by weight (pph) and from 0 to 25, 50, 75, and 100 pph, respectively. The study considered X-ray shielding, mechanical, density, water absorption, and morphological properties. The results showed that the overall X-ray shielding parameters, namely the linear attenuation coefficient (µ), mass attenuation coefficient (µm), and lead equivalent thickness (Pbeq), of the WPVC composites increased with increasing Bi2O3 contents but slightly decreased at higher wood contents (40 pph). Furthermore, comparative Pbeq values between the wood/PVC composites and similar commercial X-ray shielding boards indicated that the recommended Bi2O3 contents for the 20 pph (40 ph) wood/PVC composites were 35, 85, and 40 pph (40, 100, and 45 pph) for the attenuation of 60, 100, and 150-kV X-rays, respectively. In addition, the increased Bi2O3 contents in the WPVC composites enhanced the Izod impact strength, hardness (Shore D), and density, but reduced water absorption. On the other hand, the increased wood contents increased the impact strength, hardness (Shore D), and water absorption but lowered the density of the composites. The overall results suggested that the developed WPVC composites had great potential to be used as effective X-ray shielding materials with Bi2O3 acting as a suitable X-ray protective filler.


2021 ◽  
Vol 11 (9) ◽  
pp. 4136
Author(s):  
Rosario Pecora

Oleo-pneumatic landing gear is a complex mechanical system conceived to efficiently absorb and dissipate an aircraft’s kinetic energy at touchdown, thus reducing the impact load and acceleration transmitted to the airframe. Due to its significant influence on ground loads, this system is generally designed in parallel with the main structural components of the aircraft, such as the fuselage and wings. Robust numerical models for simulating landing gear impact dynamics are essential from the preliminary design stage in order to properly assess aircraft configuration and structural arrangements. Finite element (FE) analysis is a viable solution for supporting the design. However, regarding the oleo-pneumatic struts, FE-based simulation may become unpractical, since detailed models are required to obtain reliable results. Moreover, FE models could not be very versatile for accommodating the many design updates that usually occur at the beginning of the landing gear project or during the layout optimization process. In this work, a numerical method for simulating oleo-pneumatic landing gear drop dynamics is presented. To effectively support both the preliminary and advanced design of landing gear units, the proposed simulation approach rationally balances the level of sophistication of the adopted model with the need for accurate results. Although based on a formulation assuming only four state variables for the description of landing gear dynamics, the approach successfully accounts for all the relevant forces that arise during the drop and their influence on landing gear motion. A set of intercommunicating routines was implemented in MATLAB® environment to integrate the dynamic impact equations, starting from user-defined initial conditions and general parameters related to the geometric and structural configuration of the landing gear. The tool was then used to simulate a drop test of a reference landing gear, and the obtained results were successfully validated against available experimental data.


Sign in / Sign up

Export Citation Format

Share Document