scholarly journals Investigation of Overlapped Twisted Tapes Inserted in a Double-Pipe Heat Exchanger Using Two-Phase Nanofluid

Nanomaterials ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 1656 ◽  
Author(s):  
Mehdi Ghalambaz ◽  
Hossein Arasteh ◽  
Ramin Mashayekhi ◽  
Amir Keshmiri ◽  
Pouyan Talebizadehsardari ◽  
...  

This study investigated the laminar convective heat transfer and fluid flow of Al2O3 nanofluid in a counter flow double-pipe heat exchanger equipped with overlapped twisted tape inserts in both inner and outer tubes. Two models of the same (co-swirling twisted tapes) and opposite (counter-swirling twisted tapes) angular directions for the stationary twisted tapes were considered. The computational fluid dynamic simulations were conducted through varying the design parameters, including the angular direction of twisted tape inserts, nanofluid volume concentration, and Reynolds number. It was found that inserting the overlapped twisted tapes in the heat exchanger significantly increases the thermal performance as well as the friction factor compared with the plain heat exchanger. The results indicate that models of co-swirling twisted tapes and counter-swirling twisted tapes increase the average Nusselt number by almost 35.2–66.2% and 42.1–68.7% over the Reynolds number ranging 250–1000, respectively. To assess the interplay between heat transfer enhancement and pressure loss penalty, the dimensionless number of performance evaluation criterion was calculated for all the captured configurations. Ultimately, the highest value of performance evaluation criterion is equal to 1.40 and 1.26 at inner and outer tubes at the Reynolds number of 1000 and the volume fraction of 3% in the case of counter-swirling twisted tapes model.

2015 ◽  
Vol 752-753 ◽  
pp. 458-465
Author(s):  
P.C. Sreekumar ◽  
K. Krishnamoorthy ◽  
R. Ratheesh

Heat transfer augmentation techniques ultimately results in the reduction of thermal resistance in a conventional heat exchanger by generating higher convective heat transfer coefficient. Present study with the use of Alumina (Al2O3)/water nanofluid and baffled twisted tape inserts in double pipe heat exchanger as compound augmentation technique. Experiments were conducted to evaluate the heat transfer coefficient and friction factor for the flow through the inner tube of heat exchanger in turbulent flow range (8000<Re<60000). The effect of rectangular, circular, triangular baffled twisted tape having twist ratio (y/w) 4.2 and twisted tapes without baffles of twist ratio (y/w) 4.2 and 5.2 were studied. Experiments were conducted for both water and 0.1% volume concentration Alumina/water nanofluid. It is found that the enhancement of heat transfer coefficient by using rectangular baffled twisted tape and nanofluid is about 20%. Performance evaluation criteria were found for water and nanofluid and it was observed that rectangular baffled twisted tape performs better than other twisted tapes.


Author(s):  
Xiaoya Liu ◽  
Ming Ding ◽  
Haozhi Bian ◽  
Changqi Yan ◽  
Chun Li

Oil coolers are widely-used in nuclear power plants which cool oil flowed through the bearing of steam turbines to a suitable temperature in order for the safe operation of steam turbines. Owing to the high viscosity, the flow state of oil is generally laminar flow or transition flow, which easily leads to poor heat transfer capability and thus a large volume of the oil coolers. The insertion of twisted tapes in circular tube is a passive method widely-used for enhancing heat transfer of laminar or transition flow. However, little research focuses on the heat transfer of highly-viscous fluids inside tube using the twisted tapes. The article will present the numerical simulations of the swirling flow induced by a new coaxial cross twisted tape inserts in a heat transfer tube with lubricating oil. The effects of the clearance ratios and twist ratios on oil side heat transfer coefficient, friction factor and performance evaluation criterion will be numerically investigated using CFD computer software STAR-CCM+. The clearance ratios are 0.077, 0.154 and 0.231. The twist ratios are 2.0 and 4.0. The boundary condition of simulation is constant wall temperature for the Reynolds number ranging from 200 to 1300. The results indicate that the new coaxial cross twisted tapes are efficacious in enhancing the heat transfer of the lubricating oil inside tube. When the clear ratio is 0.077, the effect of heat transfer enhancement of the coaxial cross twisted tapes is better than that of traditional twisted tapes. Furthermore, the highest performance evaluation criterion is up to 2.3.


2019 ◽  
Vol 158 ◽  
pp. 113770 ◽  
Author(s):  
Shaojie Zhang ◽  
Lin Lu ◽  
Chuanshuai Dong ◽  
Seung Hyun Cha

Nanomaterials ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1570
Author(s):  
Yongfeng Ju ◽  
Tiezhu Zhu ◽  
Ramin Mashayekhi ◽  
Hayder I. Mohammed ◽  
Afrasyab Khan ◽  
...  

The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al2O3/water). A performance evaluation criterion (PEC) is defined to characterize the performance based on both friction factor and heat transfer. It was found that increasing the number of semi-twisted tapes increases the number of swirl flow streams and leads to an enhancement in the local Nusselt number as well as the friction factor. The average Nusselt number increases from 15.13 to 28.42 and the average friction factor enhances from 0.022 to 0.052 by increasing the number of the semi-twisted tapes from 0 to 4 for the Reynolds number of 1000 for the base fluid. By using four semi-twisted tapes, the average Nusselt number increases from 12.5 to 28.5, while the friction factor reduces from 0.155 to 0.052 when the Reynolds number increases from 250 to 1000 for the base fluid. For the Reynolds number of 1000, the increase in nanofluid concentration from 0 to 3% improves the average Nusselt number and friction factor by 6.41% and 2.29%, respectively. The highest PEC is equal to 1.66 and belongs to the Reynolds number of 750 using four semi-twisted tape inserts with 3% nanoparticles. This work offers instructions to model an advanced design of twisted tape integrated with tubes using multiple semi-twisted tapes, which helps to provide a higher amount of energy demand for solar applications.


Symmetry ◽  
2020 ◽  
Vol 12 (10) ◽  
pp. 1652
Author(s):  
Mehdi Ghalambaz ◽  
Ramin Mashayekhi ◽  
Hossein Arasteh ◽  
Hafiz Muhammad Ali ◽  
Pouyan Talebizadehsardari ◽  
...  

This paper investigates the convective heat transfer in a heat exchanger equipped with twisted tape elements to examine effects of the twisted tape truncation percentage, pitch value, position and Reynolds number using 3D numerical simulation. A symmetric heat flux is applied around the tube as the studied heat exchanger. Based on the influences in both heat transfer enhancement and pressure drop, the performance evaluation criterion (PEC) is utilized. Inserting twisted tape elements and reducing the pitch value significantly augment the Nusselt number, friction coefficient and PEC number compared to the plain tube. For the best case with a Reynolds number of 1000, the average Nusselt number increases by almost 151%, which is the case of fully fitted twisted tape at a pitch value of L/4. Moreover, increasing the twisted tape truncation percentage reduces both heat transfer and pressure drop. Furthermore, the highest heat transfer rate is achieved when the truncated twisted tape is located at the entrance of the tube. Finally, it is concluded that for P = L, L/2, L/3 and L/4, the optimum cases from the viewpoint of energy conservation are twisted tapes with truncation percentages of 75, 50, 50 and 0%, in which the related PEC numbers at a Reynolds number of 1000 are almost equal to 1.08, 1.24, 1.4 and 1.76, respectively.


Sign in / Sign up

Export Citation Format

Share Document