scholarly journals Poly(Glycerol Succinate) as an Eco-Friendly Component of PLLA and PLCL Fibres towards Medical Applications

Polymers ◽  
2020 ◽  
Vol 12 (8) ◽  
pp. 1731
Author(s):  
Dorota Kolbuk ◽  
Oliwia Jeznach ◽  
Michał Wrzecionek ◽  
Agnieszka Gadomska-Gajadhur

This study was conducted as a first step in obtaining eco-friendly fibres for medical applications using a synthesised oligomer poly(glycerol succinate) (PGSu) as an additive for synthetic poly(L-lactic acid) (PLLA) and poly (L-lactide-co-caprolactone) (PLCL). The effects of the oligomer on the structure formation, morphology, crystallisation behaviour, and mechanical properties of electrospun bicomponent fibres were investigated. Nonwovens were investigated by means of scanning electron microscopy (SEM), wide angle X-ray scattering (WAXS), differential scanning calorimetry (DSC), and mechanical testing. The molecular structure of PLLA fibres is influenced by the presence of PGSu mainly acting as an enhancer of molecular orientation. In the case of semicrystalline PLCL, chain mobility was enhanced by the presence of PGSu molecules, and the crystallinity of bicomponent fibres increased in relation to that of pure PLCL. The mechanical properties of bicomponent fibres were influenced by the level of PGSu present and the extent of crystal formation of the main component. An in vitro study conducted using L929 cells confirmed the biocompatible character of all bicomponent fibres.

Nanomaterials ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1600
Author(s):  
Maria Szymonowicz ◽  
Maciej Dobrzynski ◽  
Sara Targonska ◽  
Agnieszka Rusak ◽  
Zbigniew Rybak ◽  
...  

The replacement of affected blood vessels of the polymer material can cause imbalances in the blood haemostatic system. Changes in blood after the implantation of vascular grafts depend not only on the chemical composition but also on the degree of surface wettability. The Dallon® H unsealed hydrophilic knitted vascular prosthesis double velour was assessed at work and compare with hydrophobic vascular prosthesis Dallon®. Spectrophotometric studies were performed in the infrared and differential scanning calorimetry, which confirmed the effectiveness of the process of modifying vascular prostheses. Determination of the parameters of coagulation time of blood after contact in vitro with Dallon® H vascular prosthesis was also carried out. Prolongation of activated thromboplastin time, decreased activity of factor XII, IX and VIII, were observed. The prolonged thrombin and fibrinogen were reduced in the initial period of the experiment. The activity of plasminogen and antithrombin III and protein C were at the level of control value. The observed changes in the values of determined parameters blood coagulation do not exceed the range of referential values for those indexes. The observed changes are the result of considerable blood absorptiveness by the prosthesis of blood vessels and their sealing.


Polymers ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 46
Author(s):  
Mohammed Badwelan ◽  
Mohammed Alkindi ◽  
Osama Alghamdi ◽  
Waseem Sharaf Saeed ◽  
Abdel-Basit Al-Odayni ◽  
...  

Two poly(δ-valerolactone)/poly(ethylene-co-vinylalcohol)/β-tricalcium phosphate (PEVAL/PDVAL/β-TCP) composites containing an equal ratio of polymer and filled with 50 and 70 wt% of β-TCP microparticles were prepared by the solvent casting method. Interconnected pores were realized using the salt leached technique, and the porosity of the resulted composites was evaluated by the scanning electron microscopy (SEM) method. The homogeneity of the hybrid materials was investigated by differential scanning calorimetry (DSC) and X-ray diffraction (XRD) analysis. The prepared materials’ SEM images showed interconnected micropores that respond to the conditions required to allow their uses as scaffolds. The porosity of each scaffold was determined from micro computed tomography (micro-CT) data, and the analysis of the mechanical properties of the prepared materials was studied through the stress-strain compressive test. The proliferation test results used human mesenchymal stem cells (MSCs) to grow and proliferate on the different types of prepared materials, reflecting that the hybrid materials were non-toxic and could be biologically acceptable scaffolds. The antibacterial activity test revealed that incorporation of amoxicillin in the specimens could inhibit the bacterial growth of S. aureus. The in vitro study of the release of amoxicillin from the PEVAL/PDVAL/amoxicillin and PEVAL/PDVAL/β-TCP/amoxicillin drug carrier systems in pH media 7.4, during eight days, gave promising results, and the antibiotic diffusion in these scaffolds obeys the Fickian model.


Author(s):  
Yi-Hsuan Lee ◽  
Chao-Min Wang ◽  
Po-Yu Liu ◽  
Ching-Chang Cheng ◽  
Zong-Yen Wu ◽  
...  

Essential oils from the dried spikes ofNepeta tenuifolia(Benth) are obtained by steam distillation. Pulegone was identified as the main component in the spikes ofN. tenuifoliathrough analysis, with greater than 85% purity obtained in this study. The essential oils are extremely active against all Gram-positive and some Gram-negative reference bacteria, particularlySalmonella enterica,Citrobacter freundii, andEscherichia coli. The minimum inhibitory concentration was found to be between 0.08 and 0.78% (againstS. enterica), 0.39 and 0.78% (againstC. freundii), and 0.097 and 0.39% (againstE. coli), whereas the minimum bactericidal concentration varied in range from 0.097% to 1.04%. In general, the essential oils show a strong inhibitory action against all tested reference strains and clinical isolates. However, the antibacterial activity of EOs against bothPseudomonas aeruginosareference strains and clinical isolates was relatively lower than other Gram-negative pathogens. The essential oils ofN. tenuifoliaalso displayed bactericidal activities (MBC/MIC < 4) in this study. These findings reflect the bactericidal activity of the essential oils against a wide range of multidrug-resistant clinical pathogens in an in vitro study. In addition, we propose the fragmentation pathways of pulegone and its derivatives by LC-ESI-MS/MS in this study.


Drug Research ◽  
2018 ◽  
Vol 68 (08) ◽  
pp. 457-464
Author(s):  
Yabing Hua ◽  
Wanqing Li ◽  
Zhou Cheng ◽  
Ziming Zhao ◽  
Xiaoxing Yin ◽  
...  

To enhance the bioavailability of testosterone undecanoate (TU) and overcome the current problem of soft capsules (Andriol Testocaps®), Nano-structured lipid carriers (NLC) for TU was developed. First, suspension of TU-loaded NLC (TU-NLC) was prepared by high pressure homogenization; then adsorbent or a protective agent β-cyclodextrin was used to solidify the suspension through a vacuum system; finally, the solid powder of TU-loaded NLC (solid TU-NLC) was filled into hard capsules. The characteristics of solid TU-NLC, were investigated in vitro and vivo. The particle size of TU-NLC was about 273.3 nm, the potential was 0.156±0.04. Transmission electron microscope (TEM) revealed that the NLC was spherical and uniform. Differential scanning calorimetry (DSC) suggested the drug had been encapsulated into NLC lipid matrix. The drug release proved that solid TU-NLC showed a higher dissolution in vitro. The CaCO-2 cell permeability showed that solid TU-NLC could enhance trans-membrane absorption of the TU. Moreover, the AUC of solid TU-NLC formulations (4304±550.50 μg/L*min) was higher than commercial product Andriol Testocaps® (3075±372.50 μg/L*min). In conclusion, solid TU-NLC could enhance the rate of dissolution, and had a relatively higher bioavailability than Andriol Testocaps® in vivo Graphical Abstract.


2021 ◽  
Vol 10 (33) ◽  
pp. 2769-2772
Author(s):  
Arjun Sajjeev ◽  
Ashwini Tumkur Shivkumar ◽  
Sowmya Halasabalu Kalgeri

BACKGROUND Marginal integrity of glass ionomer as a restorative material is an important factor for the longevity of the restoration. Class V and cervical abrasions are the most critical and challenging lesions for restorations. The choice of material for restoring class V and cervical abrasions is glass ionomer cement (GIC). Sensitivity to moisture contact during the early setting stages is the drawback of GIC. To overcome the drawback, modifications of glass ionomer cement were made by the addition of chitosan. Chitosan (CH) is a natural linear polysaccharide obtained partially and fully by deacetylated chitin compounds, which are found in crab and shrimp shells, with properties like nontoxicity, biodegradability, bioadhesive, biocompatibility, and biorenewabilty which has led to its use in various fields. Thus, this study intended to evaluate the microleakage of conventional glass ionomer cement and chitosan modified glass ionomer cement using a spectrophotometer. METHODS 60 teeth extracted for orthodontic propose were selected for the study and randomly divided into two groups, class V cavities were prepared on the buccal surface and samples were restored with conventional glass ionomer cement and chitosan modified glass ionomer cement respectively, teeth were immersed in 0.5 % methylene blue for 24 hours and assessed using a spectrophotometer. RESULTS The data were analysed using the Unpaired T - test, and with statistical package for social sciences (SPSS) for Windows, version 25.0 (IBM Corp., Armonk, N.Y., USA). The confidence interval was set at 95 % and values of P < 0.05 were interpreted as statistically significant. CONCLUSIONS The study concluded that the addition of chitosan improves the mechanical properties of conventional glass ionomer cement, and a spectrophotometer can be used as a better evaluation tool in assessing microleakage. KEY WORDS Chitosan Modified GIC, Glass Ionomer Cement, Microleakage, Spectrophotometer


2016 ◽  
Vol 1 (2) ◽  
pp. 56-59
Author(s):  
Natanasabapathy Velmurugan ◽  
Poornima Reddy ◽  
Suma Balla ◽  
Sandhya S Raghu ◽  
Garlapati T Gupta ◽  
...  

ABSTRACT Introduction The aim of this study was to compare in vitro the effect of 5% calcium hypochlorite [Ca(OCl)2] and 5% sodium hypochlorite (NaOCl) on flexural strength and modulus of elasticity of root dentin. Materials and methods The available chlorine concentration of each solution was determined using iodometric titration. Standardized planoparallel dentin bars (n= 20) were divided into two test groups and one control group. The control, group 1, consisted of dentin bars stored in normal saline. The dentin bars in the two test groups were treated by exposure to following solutions: Group 2 to 5% Ca(OCl)2; and group 3 to 5% NaOCl. All the three test solutions were changed once in 15 minutes for 30 minutes. The dentin bars were then loaded to failure using three-point bend test. Results Available chlorine concentration was 64% in both the test solutions. There was a significant reduction in the flexural strength of 5% NaOCl group compared to 5% Ca(OCl)2-treated ones. A significant difference in modulus of elasticity was observed between the test groups and the control groups and also between the 5% Ca(OCl)2 and 5% NaOCl groups. Conclusion Within the limitations of this study, 5% NaOCl reduced the flexural strength and modulus of elasticity of root dentin bars more when compared to 5% Ca(OCl)2. How to cite this article Reddy P, Balla S, Raghu SS, Velmurugan N, Gupta GT, Sahoo HS. Effect of 5% Calcium Hypochlorite on Mechanical Properties of Root Dentin: An in vitro Study. J Oper Dent Endod 2016;1(2):56-59.


Sign in / Sign up

Export Citation Format

Share Document