scholarly journals Real-Time Detection of Fouling-Layer with a Non-Intrusive Continuous Sensor (NICS) during Thermal Processing in Food Manufacturing

Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1271
Author(s):  
Fernando José Cantarero Rivera ◽  
Dharmendra K Mishra ◽  
Ferhan Ozadali ◽  
Patnarin Benyathiar

The fouling of indirect shell and coil heat exchanger by heavy whipping cream (HWC) and non-fat dry milk (NFDM) was studied at aseptic Ultra-High Temperature (UHT) processing conditions (140 °C) using a novel non-intrusive sensor. The sensor emitted a heat pulse intermittently throughout the duration of the process causing an incremental increase in temperature at the tube external surface. The temperature response of the sensor varied due to the radial growth of the fouling layer formed by certain components of the products. Each heating pulse and the temperature response was studied to estimate the thermal conductivity of the fouling layer using inverse problems and parameter estimation. The changes in thermal conductivity were used as an indication of the fouling layer development during food processing at UHT temperatures. The estimated parameters from experimental results showed a decreasing trend in the thermal conductivity of HWC and NFDM from 0.35 to 0.10 and 0.63 to 0.37, respectively. An image analysis tool was developed and used to measure the fouling layer thickness at the end of each trial. The measured thickness was found to be 0.58 ± 0.15 for HWC and 0.56 ± 0.07 mm for NFDM. The fouling layer resistance for HWC and NFDM was 5.95 × 10−3 ± 1.53 × 10−3 and 1.53 × 10−3 ± 2.0 × 10−4 (m2K)/W, respectively.

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 4010
Author(s):  
Monika Gwadera ◽  
Krzysztof Kupiec

In order to find the temperature field in the ground with a heat exchanger, it is necessary to determine temperature responses of the ground caused by heat sources and the influence of the environment. To determine the latter, a new model of heat transfer in the ground under natural conditions was developed. The heat flux of the evaporation of moisture from the ground was described by the relationship taking into account the annual amount of rainfall. The analytical solution for the equations of this model is presented. Under the conditions for which the calculations were performed, the following data were obtained: the average ground surface temperature Tsm = 10.67 °C, the ground surface temperature amplitude As = 13.88 K, and the phase angle Ps = 0.202 rad. This method makes it possible to easily determine the undisturbed ground temperature at any depth and at any time. This solution was used to find the temperature field in the ground with an installed slinky-coil heat exchanger that consisted of 63 coils. The results of calculations according to the presented model were compared with the results of measurements from the literature. The 3D model for the ground with an installed heat exchanger enables the analysis of the influence of miscellaneous parameters of the process of extracting or supplying heat from/to the ground on its temperature field.


Author(s):  
Kevin D. Woods ◽  
Alfonso Ortega

Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both cooling modes, depending on the direction of the cycle upon which they operate. For proper operation, the heat pump must be connected to a constant temperature thermal reservoir which in traditional systems is the ambient air. In ground source heat pumps however, subterranean ground water is used as the thermal reservoir. To access the subterranean groundwater, “geothermal” wells are drilled into the formation. Water from the building heating or cooling system is circulated through the wells thereby promoting heat exchange between the coolant water and the subterranean formation. The potential for higher efficiency heating and cooling has increased the utilization of ground source heating ventilating and air conditioning systems. In addition, their compatibility with a naturally occurring and stable thermal reservoir has increased their use in the design of sustainable or green buildings and man-made environments. Groundwater flow affects the temperature response of thermal wells due to advection of heat by physical movement of groundwater through the aquifer. Research on this subject is scarce in the geothermal literature. This paper presents the derivation of an analytical solution for thermal dispersion by conduction and advection from hydraulic groundwater flow for a “geothermal” well. This analytical solution is validated against asymptotic analytical solutions. The traditional constant linear heat source solution is dependent on the ground formation thermal properties; the most dominant of which is the thermal conductivity. The results show that as hydraulic groundwater flow increases, the influence of the ground formation thermal conductivity on the temperature response of the well diminishes. The diminishing influence is evident in the Peclet number parameter; a comparison of thermal advection from hydraulic groundwater flow to thermal conduction by molecular diffusion.


Sign in / Sign up

Export Citation Format

Share Document