scholarly journals Analisis Kapasitas Seismik Struktur Gedung Kantor Dinas KetahananPangan Provinsi Sumatra Barat

2021 ◽  
Vol 10 (2) ◽  
Author(s):  
Thasbih Al Fajri ◽  
Rafki Imani ◽  
Zakpar Siregar

The office building of the food security office of West Sumatra Province is a multi-storey building with reinforced concrete structures built in earthquake-prone areas that have the potential for large-scale earthquakes such as the one that occurred in 2009. Based on USGS data, from December 2004 to October 2009 There have been 10 earthquakes measuring more than 5 on the Richter scale that rocked Indonesia and resulted in damage to buildings, both minor damage to heavy damage and evencollapsing. The big earthquake that occurred on September 30, 2009 in Padang City, West Sumatra, was measuring 7.6 on the Richter scale. In this study, evaluated the seismic capacity of a reinforced concrete building 4 (four) floors built in earthquake-prone areas in the city of Padang. The seismic capacity of the building is evaluated based on the standard published by Japan, namely The Standard for Seismic Evaluation of Existin Reinforced Concrete Building, 2001. In this evaluation, it only looks at the structural elements of the column on the first floor. Seismic capacity is expressed in terms of the lateral strength index and the ductility index of the building. The results of the evaluation of seismic capacity obtained the total strength index value of the building is 0.707. The seismic capacity of this building can be shown to be adequate or strongin earthquake-prone areas compared to the seismic capacity of reinforced concrete buildings that survived the massive earthquake of 7.6 on the Richter Scale in West Sumatra in September 2009. From the evaluation results on this building which is located in an area including the prone to strong earthquakes can be stated to be able to behave ductile and able to withstand an earthquake or not experience sudden collapse

2020 ◽  
Vol 156 ◽  
pp. 05005
Author(s):  
Hamdeni Medriosa

Indonesia is located in a high level of the earthquake risk area. According to USGS data, from December 2004 to October 2009, more than ten large earthquakes occurred and exceeded 5.0 Scale Richter in magnitude. Recently, the major earthquake occurred on September 28, 2018, in Palu City, Central Sulawesi, with 7.4 on the Scale Richter in magnitude and triggered a lot of building damaged. In this study, the seismic capacity of a 3-story reinforced concrete building, which collapsed due to a large earthquake in the city of Palu, was evaluated. The Standard for Seismic Evaluation of Existing Reinforced Concrete Buildings, 2001 from Japan, was used to evaluate the seismic capacity of reinforced concrete. In this analysis only reviews the column structure elements. However, the brick wall elements are considered to determine net column height. The analysis has been done only for the first floor, where there is the maximum shear force on the structure. Seismic capacity is determined by the relationship between the lateral strength and the ductility index. The obtained results of the seismic capacity analysis showed that the total strength index value of the building was 0.307 for the north to south and 0.455. The seismic capacity of this building is compared with the seismic capacity of a reinforced concrete building that survived due to a large earthquake with 7.6 on the Scale Richter in West Sumatra in September 2009. The obtained results show that the strength index value of this building is smaller than that of a building that could survive the 2009 West Sumatra earthquake.


2015 ◽  
Vol 112 (2) ◽  
Author(s):  
T. Nagae ◽  
W. M. Ghannoum ◽  
J. Kwon ◽  
K. Tahara ◽  
K. Fukuyama ◽  
...  

1986 ◽  
Vol 24 (10) ◽  
pp. 29-39
Author(s):  
T. Tsugane ◽  
K. Ishihara ◽  
K. Fukuoka ◽  
T. Watanabe

2017 ◽  
Author(s):  
Chee Ghuan Tan ◽  
Wei Ting Chia ◽  
Taksiah A. Majid ◽  
Fadzli Mohamed Nazri ◽  
Mohd Irwan Adiyanto