scholarly journals RESEARCH OF THE DIRECTIONS OF IMPROVEMENT OF PLATE EXCHANGER HEAT EXCHANGERS

Author(s):  
Iryna Gunko ◽  
Ivan Sevostyanov ◽  
Yuriy Orlyuk

The article provides an analysis of the known schemes of plate heat exchangers, their advantages and disadvantages, as well as areas for improvement. Taking into account the results of the analysis conducted in the department of dairy products of the Institute of Food Resources of the National Academy of Agrarian Sciences of Ukraine, the All-Ukrainian Scientific Research Educational Consortium, the authors developed an improved plate heat exchanger scheme, which combines high reliability, energy efficiency and heating rate of the coolant with simplicity, compactness and low construction cost, with ease of maintenance and repair (easy disassembly and cleaning). The dependences for the calculation of the main design and operating parameters of an improved heat exchanger are given.

2012 ◽  
Vol 629 ◽  
pp. 699-703
Author(s):  
Chun Sheng Guo ◽  
Wen Jing Du ◽  
Lin Cheng

The entransy loss minimization approach for the heat exchanger optimization design was established by Guo Z Y; the study based Guo Z Y’s works, found relationship between the entransy loss uniformity and the heat exchanger performance and the expression of the local entransy loss rate for heat convection was derived, numerical results of the heat transfer in a chevron plate heat exchanger and helix baffle heat exchanger show that the larger entransy loss uniformity factor appear in about Re=2000 and the entransy loss uniformity factor of chevron plate heat exchanges higher than helix baffle one.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Faraz Afshari ◽  
Azim Doğuş Tuncer ◽  
Adnan Sözen ◽  
Halil Ibrahim Variyenli ◽  
Ataollah Khanlari ◽  
...  

Purpose Using suspended nanoparticles in the base fluid is known as one of the most efficient ways for heat transfer augmentation and improving the thermal efficiency of various heat exchangers. Different types of nanofluids are available and used in different applications. The main purpose of this study is to investigate the effects of using hybrid nanofluid and number of plates on the performance of plate heat exchanger. In this study, TiO2/water single nanofluid and TiO2-Al2O3/water hybrid nanofluid with 1% particle weight ratio have been used to prepare hybrid nanofluid to use in plate type heat exchangers with three various number of plates including 8, 12 and 16. Design/methodology/approach The experiments have been conducted with the aim of examining the impact of plates number and used nanofluids on heat transfer enhancement. The performance tests have been done at 40°C, 45°C, 50°C and 55°C set outlet temperatures and in five various Reynolds numbers between 1,600 and 3,800. Also, numerical simulation has been applied to verify the heat and flow behavior inside the heat exchangers. Findings The results indicated that using both nanofluids raised the thermal performance of all tested exchangers which have a various number of plates. While the major outcomes of this study showed that TiO2-Al2O3/water hybrid nanofluid has priority when compared to TiO2/water single type nanofluid. Utilization of TiO2-Al2O3/water nanofluid led to obtaining an average improvement of 7.5%, 9.6% and 12.3% in heat transfer of heat exchangers with 8, 12 and 16 plates, respectively. Originality/value In the present work, experimental and numerical analyzes have been conducted to investigate the influence of using TiO2-Al2O3/water hybrid nanofluid in various plate heat exchangers. The attained findings showed successful utilization of TiO2-Al2O3/water nanofluid. Based on the obtained results increasing the number of plates in the heat exchanger caused to obtain more increment by using both types of nanofluids.


2010 ◽  
Vol 132 (11) ◽  
Author(s):  
M. J. White ◽  
G. F. Nellis ◽  
S. A. Klein ◽  
W. Zhu ◽  
Y. Gianchandani

Cryogenic and high-temperature systems often require compact heat exchangers with a high resistance to axial conduction in order to control the heat transfer induced by axial temperature differences. One attractive design for such applications is a perforated plate heat exchanger that utilizes high conductivity perforated plates to provide the stream-to-stream heat transfer and low conductivity spacers to prevent axial conduction between the perforated plates. This paper presents a numerical model of a perforated plate heat exchanger that accounts for axial conduction, external parasitic heat loads, variable fluid and material properties, and conduction to and from the ends of the heat exchanger. The numerical model is validated by experimentally testing several perforated plate heat exchangers that are fabricated using microelectromechanical systems based manufacturing methods. This type of heat exchanger was investigated for potential use in a cryosurgical probe. One of these heat exchangers included perforated plates with integrated platinum resistance thermometers. These plates provided in situ measurements of the internal temperature distribution in addition to the temperature, pressure, and flow rate measured at the inlet and exit ports of the device. The platinum wires were deposited between the fluid passages on the perforated plate and are used to measure the temperature at the interface between the wall material and the flowing fluid. The experimental testing demonstrates the ability of the numerical model to accurately predict both the overall performance and the internal temperature distribution of perforated plate heat exchangers over a range of geometry and operating conditions. The parameters that were varied include the axial length, temperature range, mass flow rate, and working fluid.


1999 ◽  
Vol 121 (1) ◽  
pp. 14-19 ◽  
Author(s):  
R. Z. Wang ◽  
J. Y. Wu ◽  
Y. X. Xu

Spiral plate heat exchangers as adsorbers have been proposed, and a prototype heat regenerative adsorption refrigerator using activated carbon-methanol pair has been developed and tested. Various improvements have been made, at last we get a specific cooling power for 2.6 kg-ice/day-kg adsorbent at the condition of generation temperature lower than 100°C. Discussions on the arrangements of thermal cycles and influences of design are shown.


1989 ◽  
Vol 111 (2) ◽  
pp. 300-313 ◽  
Author(s):  
S. G. Kandlikar ◽  
R. K. Shah

Plate heat exchangers are classified on the basis of number of passes on each side and the flow arrangement in each channel, taking into account the end plate effects. This results in four configurations each for the 1–1 (1 Pass–1 Pass), 2–1, 2–2, 3–3, 4–1, 4–2, and 4–4 arrangements, and six configurations for the 3–1 arrangement. These arrangements are analyzed using the Gauss–Seidel iterative finite difference method; the plate arrangement that yields the highest effectiveness in each pass configuration is identified. Comprehensive results are presented in tabular form for the temperature effectiveness P1 and log-mean temperature difference correction factor F as functions of the number of transfer units NTU1, the heat capacity rate ratio R1, and the total number of thermal plates. On the basis of these results, specific guidelines are outlined for the selection of appropriate plate heat exchanger configurations.


2017 ◽  
Vol 71 (5) ◽  
pp. 439-449
Author(s):  
Nikola Zlatkovic ◽  
Divna Majstorovic ◽  
Mirjana Kijevcanin ◽  
Emila Zivkovic

Plate heat exchanger is a type of heat exchanger that uses corrugated metal plates to transfer heat between two fluids. The plate corrugations are designed to achieve turbulence across the entire heat transfer area thus producing the highest possible heat transfer coefficients while allowing close temperature approaches. Subsequently, this leads to a smaller heat transfer area, smaller units and in some cases, fewer heat exchangers. In this work, an application for thermal and hydraulic computations of plate heat exchangers had been developed using Sharp Develop, an open source programming platform. During the development process, several literature methods and correlations for calculation of heat transfer coefficient and pressure drop in a plate heat exchanger have been tested and the selected four methods: Martin, VDI, Kumar and Coulson and Richardson have been incorporated into the software. The structure of the software is visually presented through several windows: a window for inserting input data, windows for showing the results of computation by each of the methods, a window for showing comparative analysis of the most important computation results obtained by all of the used methods and a help window for demonstrating the working principle of plate heat exchanger.


2004 ◽  
Vol 126 (4) ◽  
pp. 680-691 ◽  
Author(s):  
B. Prabhakara Rao ◽  
Sarit K. Das

A detailed experimental study on flow maldistribution from port to channel of a plate heat exchanger is presented. In general, flow maldistribution brings about an increase in pressure drop across the heat exchanger. This increase is found to depend on flow rate, number of channels and port size. Experiments show that analytical predictions of pressure drop including maldistribution effect are quite accurate for practical purposes. The results indicate that under identical conditions, maldistribution is more severe in Z-type plate heat exchanger compared to U type. Experiments are also carried out under non-isothermal realistic operating conditions, which show increased flow maldistribution at elevated temperature. Finally predictions are made for industrial plate heat exchangers, which show the limitation of adding additional plates beyond a certain limit. An insight to the physical aspects of maldistribution and its possible reduction through proper design strategy is also indicated.


2013 ◽  
Vol 597 ◽  
pp. 63-74 ◽  
Author(s):  
Jan Wajs ◽  
Dariusz Mikielewicz

In the paper the experimental analysis of passive heat transfer intensification in the case of modeled plate heat exchanger is conducted. The plate heat exchanger is chosen for the analysis because this kind of heat exchangers could be prospectively applied in the ORC systems, however other areas or application are equally possible. The experimental set-up was assembled at the Department of Energy and Industrial Apparatus of Gdansk University of Technology. The passive intensification was obtained by a modification of the heat transfer surface. The roughness of surface was increased by use of glass shot.During the experiment single-phase convective heat transfer in the single phase system was studied. The experiment was done in two stages. In the first stage the model of commercial plate heat exchanger was investigated, while in the second stage the identical one but with modified heat transfer surface. Model of heat exchanger consisted of three plates. The direct comparison of thermal and flow characteristics between both devices was possible due to assurance of equivalent conditions at the inlet to the system.The thermal and hydraulic characteristics are presented. The thermal analysis shows that in some range of heat flux density the overall heat transfer coefficient was higher for the commercial heat exchanger, while for the other was higher for the heat exchanger with modified surface. The influence of larger roughness on heat transfer cannot unequivocally be evaluated. Therefore as the next step the systematic investigations of model heat exchangers (only with one hot and one cold passage) will be conducted.


Author(s):  
Harsh Tamakuwala ◽  
Ryan Von Ness ◽  
Debjyoti Banerjee

Plate-fin heat exchangers are widely used in industries especially aerospace, cryogenics, food and chemical process industries where high heat flux surface area per unit volume is of prime importance. These heat exchangers consists of series of corrugated plates (herringbone or chevron), separated by gasket sealing. Chevron angled plates are one of the most commonly used type of geometry. The complex design of chevron plate heat exchanger, induces high turbulence and flow reversals causing high heat transfer through the plates. This paper discusses about the computational fluid dynamics simulations conducted over a simplified geometry of Chevron Plate Heat Exchanger to understand the formulation of vortices at different Reynold’s number for various aspect ratios. A single phase laminar flow with periodic boundary condition is used for analysis of the fluid behavior in a unit pattern of the corrugation geometry. Based on different flow and geometric conditions, varying amounts of swirl-flows are observed and different behavior of shear stress and heat transfer plot along the length of the plate is observed. At higher Reynolds numbers (Re), the re-circulations and mixing by the induced vortices causes significant rise of heat flux, with marginal increase in friction factor.


Author(s):  
Wei Li ◽  
Hongxia Li

This paper provides a numerical analysis on precipitation and particulate fouling in a corrugated plate heat exchanger. This analysis started from the mass balance fouling model, and Realizable κ-ε model with non-equilibrium wall functions is used in the 3D numerical simulation considering the realistic geometries of the flow channel to obtained Nusselt number and wall shear stress, while Von-Karman analogy is used to obtain mass transfer coefficient. The numerical analysis is verified by experimental study. The predicted influence of fluid velocity in fouling resistance is compatible with experimental data that it can help to optimize the design of plate heat exchangers. The investigation significantly simplifies the fouling analysis of complex flow fields and can be used to assess the fouling potential of corrugated plate heat exchangers.


Sign in / Sign up

Export Citation Format

Share Document