scholarly journals Simultaneous High Dynamic Range Algorithm, Testing, and Instrument Simulation

2022 ◽  
Vol 924 (2) ◽  
pp. 63
Author(s):  
James Paul Mason ◽  
Daniel B. Seaton ◽  
Andrew R. Jones ◽  
Meng Jin ◽  
Phillip C. Chamberlin ◽  
...  

Abstract Within an imaging instrument’s field of view, there may be many observational targets of interest. Similarly, within a spectrograph’s bandpass, there may be many emission lines of interest. The brightness of these targets and lines can be orders of magnitude different, which poses a challenge to instrument and mission design. A single exposure can saturate the bright emission and/or have a low signal-to-noise ratio (S/N) for faint emission. Traditional high dynamic range (HDR) techniques solve this problem by either combining multiple sequential exposures of varied duration or splitting the light to different sensors. These methods, however, can result in the loss of science capability, reduced observational efficiency, or increased complexity and cost. The simultaneous HDR method described in this paper avoids these issues by utilizing a special type of detector whose rows can be read independently to define zones that are then composited, resulting in areas with short or long exposure measured simultaneously. We demonstrate this technique for the Sun, which is bright on disk and faint off disk. We emulated these conditions in the lab to validate the method. We built an instrument simulator to demonstrate the method for a realistic solar imager and input. We then calculated S/Ns, finding a value of 45 for a faint coronal mass ejection and 200 for a bright one, both at 3.5  ⊙ N —meeting or far exceeding the international standard for digital photography that defines an S/N of 10 as acceptable and 40 as excellent. Future missions should consider this type of hardware and technique in their trade studies for instrument design.

2009 ◽  
Author(s):  
Leo H. C. Braga ◽  
Suzana Domingues ◽  
José G. Gomes ◽  
Antonio C. Mesquita

2021 ◽  
Vol 7 (4) ◽  
pp. 104-110
Author(s):  
Mariia Globa ◽  
Sergey Lesovoi

The paper describes application of standard gain calibration using redundancy for a 48-antenna prototype of Siberian Radioheliograph. Traditionally, for calibration, the visibilities were measured only between adjacent antennas since they have the highest signal-to-noise ratio and are sufficient for phase calibration. We have shown that this limited set of visibilities did not allow using the antenna array redundancy potential and obtaining images with a high dynamic range on a permanent basis. Images without amplitude calibration contain many artifacts and require special care when analyzed. The inclusion of visibility measurement between antennas with a double step made it possible to significantly increase the accuracy of solving the system of equations for amplitudes. Images constructed using both phase and amplitude calibrations do not have visible artifacts and are more reliable.


2021 ◽  
Vol 13 ◽  
pp. 130004
Author(s):  
Guillermo Abramson

We report observations of the total solar eclipse of 14 December 2020, during which a coronal mass ejection was seen to propagate. A comprehensive set of photographs covering a high dynamic range of exposure enabled characterization of its dimensions. Displacement of the front can be seen during the few minutes of totality.


2021 ◽  
Vol 7 (4) ◽  
pp. 98-103
Author(s):  
Mariia Globa ◽  
Sergey Lesovoi

The paper describes application of standard gain calibration using redundancy for a 48-antenna prototype of Siberian Radioheliograph. Traditionally, for calibration, the visibilities were measured only between adjacent antennas since they have the highest signal-to-noise ratio and are sufficient for phase calibration. We have shown that this limited set of visibilities did not allow using the antenna array redundancy potential and obtaining images with a high dynamic range on a permanent basis. Images without amplitude calibration contain many artifacts and require special care when analyzed. The inclusion of visibility measurement between antennas with a double step made it possible to significantly increase the accuracy of solving the system of equations for amplitudes. Images constructed using both phase and amplitude calibrations do not have visible artifacts and are more reliable.