Treatment of Complicated Tibial Plateau Fractures With Dual Plating Via a 2-incision Technique

Author(s):  
Yong Zhang ◽  
De-gang Fan ◽  
Bao-an Ma ◽  
Si-guo Sun
2013 ◽  
Vol 25 (2) ◽  
pp. 77-83 ◽  
Author(s):  
Kye-Youl Cho ◽  
Hyun-Sup Oh ◽  
Jae-Ho Yoo ◽  
Duk-Hyun Kim ◽  
Young-Joo Cho ◽  
...  

2020 ◽  
Vol 6 (4) ◽  
pp. 943-948
Author(s):  
Yash Parikh ◽  
Tejas Patil ◽  
Sunil Kulkarni ◽  
Nikhil Lambat ◽  
Shrinivas Jadhav ◽  
...  

Author(s):  
Angelo V. Vasiliadis ◽  
Frideriki Poutoglidou ◽  
Dimitrios Metaxiotis ◽  
Anastasios Mpeletsiotis

Objective: This study was designed to evaluate the mid-term radiological and functional outcome of tibial plateau fractures treated by plating. Methods: Patients with Schatzker type V and type VI tibial plateau fractures who were managed with open reduction and internal fixation using dual plates were included in this retrospective study. The functional evaluation of the patients was carried out with the visual analogue scale (VAS), the health-related quality of life status was measured using the Short Form-36 (SF-36) and the dimensions of pain, stiffness and function were assessed using the Western Ontario and McMaster Universities Arthritis Index (WOMAC). For the radiological outcome evaluation, the modified Rasmussen criteria were used. Results: 57 patients (30 male and 27 female) were included in the study with a mean follow-up of 50.88 months. There were 23 Schatzker type V and 34 Schatzker type VI fractures. The majority of patients (86%) had a good to excellent radiological outcome. The mean VAS score was 1.65 for all the patients. The functional outcome was excellent in the majority of the patients. Among them, 5.3% (n = 3) suffered wound infection and all of the wounds healed after different treatments. All patients returned to their pre-injury activities of daily living and employment status, while 53% of the patients returned to sporting activities. Conclusion: Our findings support previous literature, which has demonstrated that bicondylar tibial plateau fractures can provide good to excellent radiological and functional outcomes if they were treated with open reduction and internal fixation with dual plating. Keywords: tibial plateau fracture; bicondylar fracture; Schatzker classification; dual plating


Author(s):  
Shradha Bora S. ◽  
Senthil L. ◽  
Thiyagarajan U. ◽  
Pradeep J. P. ◽  
Gokul Raj D.

<p class="abstract"><strong>Background:</strong> Medial tibial plateau fractures is a subtype of proximal tibial fractures that involve the articular surface and can present in several distinct patterns. Purpose of this study was to assess the clinical outcome of stabilizing these biplanar medial tibial plateau fractures using dual plating technique through a single incision.</p><p class="abstract"><strong>Methods:</strong> Between 2017 to 2019, 12 men and 8 women with closed medial tibial plateau fracture who underwent reconstruction using two plates through a posteromedial approach were included in the study group. The fractures were classified using the three column concept of Lou.<strong></strong></p><p class="abstract"><strong>Results:</strong> One patient had an articular step off that was unacceptable and two patients had an acceptable articular step off. Functional assessment was done using the objective scoring of Oxford knee score criteria and radiological assessment was done using the Rasmussen modified score.</p><p class="abstract"><strong>Conclusions:</strong> Biplanar reconstruction using dual plates is a reliable and safe technique to reconstruct complex medial tibial plateau fractures.</p>


Author(s):  
Siddaram N. Patil ◽  
Pandurangaiah Srinivas ◽  
Divya Bhandary

<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">Schatzker‘s type V and type VI fractures are bicondylar tibial plateau fractures which pose a challenge to the treating orthopaedician. Several studies have compared unilateral locked plate and double plating for their treatment and showed no statistically significant difference between these two fixation methods. So the quest for ideal implant for internal fixation (unilateral plating and dual plating) of these fractures continues. Hence we decided to do this study.</span></p><p class="abstract"><strong>Methods:</strong> A prospective study of Surgical Management of thirty seven cases of Schatzker’s type V and VI tibial plateau fractures by different types of plate osteosynthesis (single unilateral locking plate and dual incision locking buttress plate) was carried out. The functional outcomes were assessed by the hospital for special surgery knee score system.<strong></strong></p><p class="abstract"><strong>Results:</strong> 18 patients were fixed with a unilateral locking plate, 19 patients were fixed with a dual incision bilateral locking plates. All patients had satisfactory articular surface reduction and axis of alignment on immediate postoperative radiographs. All cases achieved union by 4.8 months approximately. All patients had either excellent or good HSS score. Mean HSS score at recent follow-up was 86.10 in DP group and 83 in SP groups (t value 2.81, p values 0.008)<span lang="EN-IN">. </span></p><p class="abstract"><strong>Conclusions:</strong> We conclude that single plating and dual plating fixation of complex proximal tibial plateau fracture Schatzker‘s type 5 and type 6 ensures stable fixation, immediate mobilization, satisfactory radiological outcome, very high union rates and excellent functional assessment outcome with a very low rate of complications<span lang="EN-IN">.</span></p>


2004 ◽  
Vol 18 (10) ◽  
pp. 649-657 ◽  
Author(s):  
David P. Barei ◽  
Sean E. Nork ◽  
William J. Mills ◽  
M. Bradford Henley ◽  
Stephen K. Benirschke

Sign in / Sign up

Export Citation Format

Share Document