On-Body Chemo/Bio-Sensing - Opportunities and Challenges

2014 ◽  
Vol 96 ◽  
pp. 78-88
Author(s):  
Giusy Matzeu ◽  
Cormac Fay ◽  
Conor O’Quigley ◽  
Dylan Orpen ◽  
Simon Coleman ◽  
...  

In recent years, there has been significant progress in a number of sensing technologies related to on-body measurements, such as platforms for monitoring respiration, heart rate, location and movement. In these cases, the sensing element (s) are based on highly effective transducers that are increasingly integrated into garments such that they are becoming innocuous to the user. In contrast, the area of on-body chemical sensing remains highly under-developed. In this paper, we will address the significant challenges that are inhibiting the practical realisation of reliable chemical sensors and biosensors capable of generating accurate data in real time.

2000 ◽  
Author(s):  
K. Zaglaniczny ◽  
W. Shoemaker ◽  
D. S. Gorguze ◽  
C. Woo ◽  
J. Colombo

Author(s):  
Nobuki Hashiguchi ◽  
Lim Yeongjoo ◽  
Cyo Sya ◽  
Shinichi Kuroishi ◽  
Yasuhiro Miyazaki ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 999
Author(s):  
Henry Dore ◽  
Rodrigo Aviles-Espinosa ◽  
Zhenhua Luo ◽  
Oana Anton ◽  
Heike Rabe ◽  
...  

Heart rate monitoring is the predominant quantitative health indicator of a newborn in the delivery room. A rapid and accurate heart rate measurement is vital during the first minutes after birth. Clinical recommendations suggest that electrocardiogram (ECG) monitoring should be widely adopted in the neonatal intensive care unit to reduce infant mortality and improve long term health outcomes in births that require intervention. Novel non-contact electrocardiogram sensors can reduce the time from birth to heart rate reading as well as providing unobtrusive and continuous monitoring during intervention. In this work we report the design and development of a solution to provide high resolution, real time electrocardiogram data to the clinicians within the delivery room using non-contact electric potential sensors embedded in a neonatal intensive care unit mattress. A real-time high-resolution electrocardiogram acquisition solution based on a low power embedded system was developed and textile embedded electrodes were fabricated and characterised. Proof of concept tests were carried out on simulated and human cardiac signals, producing electrocardiograms suitable for the calculation of heart rate having an accuracy within ±1 beat per minute using a test ECG signal, ECG recordings from a human volunteer with a correlation coefficient of ~ 87% proved accurate beat to beat morphology reproduction of the waveform without morphological alterations and a time from application to heart rate display below 6 s. This provides evidence that flexible non-contact textile-based electrodes can be embedded in wearable devices for assisting births through heart rate monitoring and serves as a proof of concept for a complete neonate electrocardiogram monitoring system.


Nanoscale ◽  
2020 ◽  
Author(s):  
Congxi Huang ◽  
Guorui Chen ◽  
Ardo Nashalian ◽  
Jun Chen

Chemical sensors allow for continuous detection and analysis of underexplored molecules on the human body and the surroundings, which hold bright applications on human healthcare and environmental protection. With the...


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
Y Barmenkova ◽  
E Dushina ◽  
N Burko ◽  
V Oleinikov

Abstract Purpose To assess the importance of highly effective lipid-lowering therapy with atorvastatin in the normalization of the autonomic regulation of cardiac activity in patients with myocardial infarction with ST segment elevation (STEMI). Methods The study included 130 patients with STEMI aged 51.3±8.9 years, the majority of males (91%). Inclusion criteria: age from 35 to 70 years, STEMI confirmed by ECG and the level of biomarkers (troponin I, CK-MB), the presence of hemodynamically significant stenosis of a culprit artery according to coronary angiography provided that other coronary arteries are occluded no more than 50%, left main coronary artery - not more than 30%. Exclusion criteria: a history of myocardial infarction, CHF III-IV NYHA, bundle branch block, atrial fibrillation, artificial pacemaker. All patients took atorvastatin at a dose of 40–80 mg/day for 48 weeks after STEMI. As part of a further study at the 7th-9th day and 48 weeks after STEMI, 24-hour ECG monitoring was performed with the Astrocard system. The spectral parameters of heart rate variability (HRV) were evaluated: TotP (ms2), ULF (ms2), VLF (ms2), LF (ms2), HF (ms2), LF / HF. By the 48th week of treatment, patients were divided into groups depending on the achievement of the target level of low density lipoproteins (LDL) of less than 1.4 mmol / l or less than 50% of the initial values: 64 people who reached target values of LDL and formed the group of high-effective lipid-lowering therapy “H”, the group of low effective treatment “L” included 66 patients whose LDL did not meet the recommended level. The groups were matched by gender, age, and anthropometric data. Results In the “H” group, by the 48th week, a pronounced power amplification of all spectral components was obtained. The TotP parameter increased from 13021 (95% CI 10967; 15076) ms2 to 20988 (95% CI 17617; 24358) ms2 (p=0.0001); HF - from 164 (95% CI 105; 222) ms2 to 249 (95% CI 178; 321) ms2 (p=0.003). An increase in the low-frequency components of HRV was observed: an increase in ULF from 10695 (95% CI 8985; 12406) ms2 to 20401 (95% CI 15099; 25703) ms2 (p=0.0001), VLF - from 1473 (95% CI 1212; 1734) ms2 to 1734 (95% CI 1478; 1990) ms2 (p=0.01), LF - from 761 (95% CI 573; 949) ms2 to 909 (95% CI 736; 1082) ms2 (p=0.02). Against the background of an increase in all parameters of the frequency spectrum, the sympathovagal balance coefficient LF / HF decreased from 6.6 (95% CI 5.7; 7.6) to 5.2 (95% CI 4.3; 6.1) ( p=0.004). An analysis of the HRV indicators dynamics in the L group revealed an increase in only the total spectrum power - TotP from 12740 (95% CI 10947; 14533) ms2 to 20195 (95% CI 16619; 23770) ms2. Conclusions Highly effective therapy with atorvastatin in STEMI patients helps to normalize the parameters of the autonomic regulation of heart rate in the post-infarction period due to the increased effects of parasympathetic activity. Funding Acknowledgement Type of funding source: None


Author(s):  
Pramudya Rakhmadyansyah Sofyan ◽  
Rizdha Wahyudi ◽  
Diandri Perkasa Putra ◽  
Alvin Sahroni ◽  
Nur Widiasmara ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document