Finite Element Simulation of Reinforced Concrete Beams Strengthened with Externally Bonded Carbon Fibre Reinforced Polymer

Author(s):  
C.A. Issa ◽  
G.A. Saad

Concrete, a mixture of different aggregates bonded with cement, first developed around 150BC in Rome has been bedrock to the modern Infrastructure. It is used to build everything from roads, bridges, dams to sky scrapers. Strengthening concrete is traditionally done by using steels but the developments in technology in recent decades allowed to use fiber reinforced plastics which are externally bonded to concrete . Such composite materials offer high strength, low weight, corrosion resistance, high fatigue resistance, easy and rapid installation and minimal change in structural geometry. This study investigates the behavior of reinforced concrete beams bonded with fiber composites. A numerical study is conducted to study the behavior of RC beam under Static third point loading. Concrete beam specimens with dimensions of 150 mm width, 300 mm height, and 2600 mm length are modelled. These beams are externally bonded with Glass Fiber Reinforced Polymer (GFRP) sheets and Carbon Fibre Reinforced Polymer (CFRP) sheets. In present study, we examine the performance of reinforced concrete beams which are bonded with GFRP and CFRP sheets with various thicknesses (1, 2 & 3 mm) using ABAQUS in terms of failure modes, enhancement of load capacity, load-deflection analysis and flexural behaviour


2000 ◽  
Vol 27 (5) ◽  
pp. 1005-1010 ◽  
Author(s):  
Khaled A Soudki ◽  
Ted G Sherwood

The viability of carbon fibre reinforced polymer (CFRP) laminates for the strengthening of corrosion damaged reinforced concrete bridge girders is addressed in this paper. Ten reinforced concrete beams (100 × 150 × 1200 mm) with variable chloride levels (0-3%) were constructed. Six beams were strengthened by externally epoxy bonding CFRP laminates to the concrete surface. The tensile reinforcements of three unstrengthened and four strengthened specimens were subjected to accelerated corrosion by means of impressed current to 5, 10, and 15% mass loss. Strain gauges were placed on the CFRP laminates to monitor and quantify tensile strains induced by the corrosion process. Following the corrosion phase, the specimens were tested in flexure in a four-point bending regime. Test results revealed that CFRP laminates successfully confined the corrosion cracking, and the total expansion of the laminate exhibited an exponential increase throughout the corrosion process. All the strengthened beams exhibited increased stiffness over the unstrengthened specimens and marked increases in the yield and ultimate strength. The CFRP strengthening scheme was able to restore the capacity of corrosion damaged concrete beams up to 15% mass loss.Key words: CFRP laminates, corrosion, confinement, expansion, load tests, strengthening, bond strength, reinforced concrete.


Sign in / Sign up

Export Citation Format

Share Document