scholarly journals Influence of temperature on the performance of anaerobic treatment systems of municipal wastewater

Water SA ◽  
2018 ◽  
Vol 44 (2 April) ◽  
Author(s):  
Silvânia Lucas Dos Santos ◽  
Sílvia Raphaele Morais Chaves ◽  
Adrianus Van Haandel

Anaerobic sewage treatment systems, especially upflow anaerobic sludge blanket (UASB) reactors, have found wide application over the past decades, particularly in regions with a warm climate. A low sewage temperature is generally considered as a factor contributing to poor performance, characterized by an increase of the COD fractions in the effluent and the generated sludge, and decreasing the fraction that is transformed into methane. An experimental investigation was carried out at pilot scale to establish the values of the three COD fractions for different values of temperature and the applied organic load. The sludge age of the anaerobic treatment, together with temperature, was identified as the main operational variable that affects the efficiency of anaerobic treatment. An empirical expression was derived for the values of the three factions as a function of these two variables. From the results of the experimental investigation it was apparent that there is no point in applying a sludge age of more than 100 d, when the reactor is near its best performance. An expression was derived to establish the hydraulic retention time for maximum digestion efficiency as a function of temperature, concentration and composition of organic material and sludge mass. It was established that the main limit to the sludge hold-up in UASB reactors treating sewage is not the sludge settleability, but rather the break-up of flocs leading to loss of small, poorly-settling particles.

2005 ◽  
Vol 52 (1-2) ◽  
pp. 299-305 ◽  
Author(s):  
R.C. Leitão ◽  
J.A. Silva-Filho ◽  
W. Sanders ◽  
A.C. van Haandel ◽  
G. Zeeman ◽  
...  

In this investigation, the performance of Upflow Anaerobic Sludge Blanket (UASB) reactors treating municipal wastewater was evaluated on the basis of: (i) COD removal efficiency, (ii) effluent variability, and (iii) pH stability. The experiments were performed using 8 pilot-scale UASB reactors (120 L) from which some of them were operated with different influent COD (CODInf ranging from 92 to 816 mg/L) and some at different hydraulic retention time (HRT ranging from 1 to 6 h). The results show that decreasing the CODInf, or lowering the HRT, leads to decreased efficiencies and increased effluent variability. During this experiment, the reactors could treat efficiently sewage with concentration as low as 200 mg COD/L. They could also be operated satisfactorily at an HRT as low as 2 hours, without problems of operational stability. The maximum COD removal efficiency can be achieved at CODInf exceeding 300 mg/L and HRT of 6 h.


2013 ◽  
Vol 33 (2) ◽  
pp. 367-378 ◽  
Author(s):  
Estevão Urbinati ◽  
Rose M. Duda ◽  
Roberto A. de Oliveira

In this study it was evaluated the effects of hydraulic retention time (HRT) and Organic Loading Rate (OLR) on the performance of UASB (Upflow Anaerobic Sludge Blanket) reactors in two stages treating residual waters of swine farming. The system consisted of two UASB reactors in pilot scale, installed in series, with volumes of 908 and 188 L, for the first and second stages (R1 and R2), respectively. The HRT applied in the system of anaerobic treatment in two stages (R1 + R2) was of 19.3, 29.0 and 57.9 h. The OLR applied in the R1 ranged from 5.5 to 40.1 kg CODtotal (m³ d)-1. The average removal efficiencies of chemical oxygen demand (COD) and total suspended solids (TSS) ranged, respectively, from 66.3 to 88.2% and 62.5 to 89.3% in the R1, and from 85.5 to 95.5% and 76.4 to 96.1% in the system (R1 + R2). The volumetric production of methane in the system (R1 + R2) ranged from 0.295 to 0.721 m³CH4 (m³ reactor d)-1. It was found that the OLR applied were not limiting to obtain high efficiencies of CODtotal and TSS removal and methane production. The inclusion of the UASB reactor in the second stage contributed to increase the efficiencies of CODtotal and TSS removal, especially, when the treatment system was submitted to the lowest HRT and the highest OLR.


2014 ◽  
Vol 34 (1) ◽  
pp. 124-142 ◽  
Author(s):  
Estevão Urbinati ◽  
Roberto Alves de Oliveira

In this work it was evaluated the performance of two systems of swine wastewater treatment consisting of two-stage upflow anaerobic sludge blanket (UASB) reactors, with and without post-treatment in sequencing batch reactor (SBR), fed continuously, with aerobic phase. The UASB reactors in the first stage had 908 L in the sets I and II, and in the second stage 350 and 188 L, respectively. In the set II the post-treatment was performed in a SBR of 3,000 L. The hydraulic detention times in the anaerobic treatment systems were 100, 75 and 58 h in the set I; 87, 65 and 51 h in the set II; and 240 and 180 h in the SBR. The volumetric organic load applied in the first stage UASB reactors ranged from 6.9 to 12.6 g total COD (L d)-1 in the set I and 7.5 to 9.8 g total COD (L d)-1 in the set II. The average removal efficiencies of total COD, total phosphorus (Ptotal), and Kjeldahl and organic nitrogen (KN and Norg) in the anaerobic treatment systems were similar and reached maximum values of 97%, 64%, 68%, and 98%. In the SBR, the removal efficiencies of total COD and thermotolerant coliforms were up to 62 and 92% resulting, respectively, in effluent concentrations of 135 mg L-1 and 2x10(4)MPN (100 mL)-1. For Ptotal, total nitrogen (TN) and Norg, the average removal efficiencies in the SBR were up to 58, 25 and 73%, respectively.


2019 ◽  
Vol 80 (3) ◽  
pp. 418-425 ◽  
Author(s):  
T. Bressani-Ribeiro ◽  
L. A. Chamhum-Silva ◽  
C. A. L. Chernicharo

Abstract There are hundreds of full-scale upflow anaerobic sludge blanket (UASB) reactors in operation in various parts of the tropical world, notably in India and Latin America, Brazil being the holder of the largest park of anaerobic reactors for sewage treatment in the world. Despite the recognized advantages of UASB reactors, there are problems that have prevented their maximum operational performance. Neglecting the existence and delaying the solution of these challenges can jeopardize the important advances made to date, impacting the future of anaerobic technology in Brazil and in other countries. This work aims to evaluate the operational performance of five full-scale UASB reactors in Brazil, taking into account a monitoring period ranging between two and six years. The main observed design, construction, and operational constraints are discussed. Some outlooks for important upcoming developments are also provided, considering that most of the observed drawbacks can be tackled without significant increases on reactor costs.


1986 ◽  
Vol 18 (12) ◽  
pp. 41-53 ◽  
Author(s):  
Look Hulshoff Pol ◽  
Gatze Lettinga

Presently anaerobic wastewater treatment is becoming an accepted simple technology for the treatment of a variety of wastewaters. Of the different treatment systems that have been developed the UASB process (Upflow Anaerobic Sludge Blanket) has found the widest application. Almost all of the more than 60 full scale UASB reactors in operation now, are running satisfactorily. The excellent sludge retention generally found in UASB-reactors is obtained by sludge granulation, which can be seen as a sludge immobilization process. The presently available insight into the sludge granulation process is briefly presented, together with the strategy to be applied for performing a proper first start-up and secondary start-up of UASB reactors, viz. using granular seed sludge. The effect of the presence of SS with regard to the loading potentials of anaerobic treatment systems will be discussed. The experiences obtained with some full scale applications of the UASB-process are presented.


2021 ◽  
Vol 83 (8) ◽  
pp. 1920-1931
Author(s):  
M. J. Moya-Llamas ◽  
A. Trapote ◽  
D. Prats

Abstract An Upflow Anaerobic Sludge Blanket reactor combined with a two-stage membrane bioreactor were operated for 193 days in order to evaluate the biological removal of carbamazepine (CBZ) from low-strength municipal wastewater. The system worked in three different organic load stages (0.7 ± 0.1 kg COD·m−3·d−1, 0.4 ± 0.1 kg COD·m−3·d−1 and 0.1 ± 0.0 kg COD·m−3·d−1) to assess the impact of the influent OLR on operational parameters such as anaerobic and aerobic sludge retention time (SRT), acidity, volatile fatty acids (VFAs), biomass activity or biogas production. The highest carbamazepine removals were achieved during the anaerobic stage (UASB reactor), reaching averages of 48.9%, 48.0% and 38.2% operating at high, medium and low OLR, respectively. The aerobic treatment (MBR) served as post-treatment, improving the removals, and the global UASB-MBR system reached averages of 70.0%, 59.6% and 49.8% when the influent was at medium and low OLR, respectively. The results demonstrate the potential of combined biological systems on the removal of recalcitrant pharmaceuticals.


1993 ◽  
Vol 27 (9) ◽  
pp. 75-82 ◽  
Author(s):  
J. J. Bogte ◽  
A. M. Breure ◽  
J. G. van Andel ◽  
G. Lettinga

A survey was made on the feasibility of on-site anaerobic treatment of domestic wastewater from small scale emissions in The Netherlands. Three 1.2 m3 UASB-reactors (Upflow Anaerobic Sludge Blanket) were tested in different rural locations. The survey made clear that the efficiency of the process is highly dependent on the reactor temperature. Below 12 °C purification was predominantly based on settling, while above 12 °C microbial degradation of organic matter increased. Efficiencies for the removal of total COD and BOD of two of the reactors ranged between 33 and 60%, equalising well performing septic tanks. In one of the reactors the average production of biogas, with a methane content of 78%, was 67 liters per day. Complete transformation of volatile fatty acids (VFA) into biogas was achieved during 3 to 4 months a year at temperatures above 15 °C. In this period, during the second year of operation, the average efficiencies for COD and BOD removal were 60 and 72% respectively, while the maximum gas production reached 300 liters per day. In the latter period the mineralisation rate exceeded the input rate of organic matter, resulting in a decrease of settled material in the reactor. The possibility of high efficiencies during summertime in The Netherlands and the positive results of similar experiments in Indonesia and Latin America lead to the conclusion that anaerobic digestion is a promising process for the (pre-)treatment of domestic waste water in (sub)tropical countries.


2009 ◽  
Vol 59 (9) ◽  
pp. 1847-1853 ◽  
Author(s):  
R. C. Leitão ◽  
S. T. Santaellla ◽  
A. C. van Haandel ◽  
G. Zeeman ◽  
G. Lettinga

The effects of hydraulic retention time (HRT) and influent COD concentration (CODInf) on Specific Methanogenic Activity (SMA) and the biodegradability of an anaerobic sludge need to be elucidated because of the discordant results available in literature. This information is important for the operation of anaerobic reactors and design of the sludge post-treatment unit. For this study, sludge samples obtained from eight pilot-scale Upflow Anaerobic Sludge Blanket (UASB) reactors were tested. The reactors were fed with municipal wastewater and operated with different sets of HRT and influent concentrations until the steady state was established. The results show that at a lower HRT, sludge with relatively higher SMA develops. A slight trend of declining SMA at increasing CODInf was found for reactors operated at longer HRTs; however, further experiments are necessary for more definitive conclusions. The sludge from reactors operated at longer HRTs and with lower CODInf resulted in lower biodegradability. Results also showed that it is ineffective to design a UASB reactor with a longer HRT to cope with organic shock loads.


1999 ◽  
Vol 39 (5) ◽  
pp. 177-185 ◽  
Author(s):  
Tarek A. Elmitwalli ◽  
Marcel H. Zandvoort ◽  
Grietje Zeeman ◽  
Harry Bruning ◽  
Gatze Lettinga

The treatment of sewage at a temperature of 13°C was investigated in three reactors (each 3.84 litre) a UASB and two anaerobic hybrid (AH) reactors with small sludge granules with an average diameter of 0.73 mm. The media used in the AH reactors were vertical polyurethane foam sheets. The reactors were operated at a HRT of 8 h. The use of small sludge granules and operating the reactors at low upflow velocity (1.8 m/d) improved suspended COD removal efficiencies for the UASB reactor. Moreover, the use of sheets in the AH reactors significantly increased suspended COD removal efficiencies as compared to the UASB and reached to 87% for pre-settled sewage treatment. The treatment of pre-settled sewage instead of raw sewage in AH reactors significantly increased colloidal and dissolved COD removal efficiencies with 13% and 12% respectively and colloidal COD removal efficiency for the UASB reactor with 13%. At ‘steady state’ for pre-settled sewage treatment, the AH reactors removed 64% of the total COD which is significantly higher by 4% than the UASB reactor. Therefore, the anaerobic treatment of domestic sewage at low temperature can be improved by treating pre-settled sewage in shallow AH reactors containing small sludge granules.


2002 ◽  
Vol 45 (10) ◽  
pp. 213-218 ◽  
Author(s):  
I. Angelidaki ◽  
B.K. Ahring ◽  
H. Deng ◽  
J.E. Schmidt

Combined anaerobic digestion of olive oil mill effluent (OME) with swine manure, was investigated. In batch experiments was shown that for anaerobic degradation of OME alone nitrogen addition was needed. A COD:N ratio in the range of 65:1 to 126:1 was necessary for the optimal degradation process. Furthermore, it was found that methane productions rates during digestion of either swine manure alone or OME alone were much lower than the rates achieved when OME and manure were digested together. Admixing OME with manure at a concentration of 5 to 10% OME resulted in the highest methane production rates. Using upflow anaerobic sludge blanket (UASB) reactors, it was shown that codigestion of OME with swine manure (up to 50% OME) was successful with a COD reduction up to 75%. The process was adapted for degradation of OME with stepwise increase of the OME load to the UASB reactor. The results showed that the high content of ammonia in swine manure, together with content of other nutrients, make it possible to degrade OME without addition of external alkalinity and without addition of external nitrogen source. Anaerobic treatment of OME in UASB reactors resulted in reduction of simple phenolic compounds such as mequinol, phenyl ethyl alcohol and ethyl methyl phenol. After anaerobic treatment the concentration of these compounds was reduced between 75 and 100%. However, the concentration of some degradation products such as methyl phenol and ethyl phenol were detected in significantly higher concentrations after treatment, indicating that the process has to be further optimised to achieve satisfactory removal of all xenobiotic compounds.


Sign in / Sign up