Abstract Starch, glycogen, maltooligosaccharides, and other α-1,4- and α-1,6-linked glucose carbohydrates, exclusive of resistant starch, are collectively termed "dietary starch". This nutritionally important fraction is increasingly measured for use in diet formulation for animals as it can have positive or negative effects on animal performance and health by affecting energy supply, glycemic index, and formation of fermentation products by gut microbes. AOAC Method 920.40 that was used for measuring dietary starch in animal feeds was invalidated due to discontinued production of a required enzyme. As a replacement, an enzymatic-colorimetric starch assay developed in 1997 that had advantages in ease of sample handling and accuracy compared to other methods was considered. The assay was further modified to improve utilization of laboratory resources and reduce time required for the assay. The assay is quasi-empirical: glucose is the analyte detected, but its releaseis determined by run conditions and specification ofenzymes. The modified assay was tested in an AOAC collaborative study to evaluate its accuracy and reliability for determination of dietary starch in animalfeedstuffs and pet foods. In the assay, samples are incubated in screw cap tubes with thermostable α-amylase in pH 5.0 sodium acetate buffer for 1 h at 100°C with periodic mixing to gelatinize and partially hydrolyze α-glucan. Amyloglucosidase is added, and the reaction mixture is incubatedat 50°C for 2 h and mixed once. After subsequent addition of water, mixing, clarification, and dilution as needed, free + enzymatically released glucose are measured. Values from a separate determination of free glucose are subtracted to give values forenzymatically released glucose. Dietary starch equals enzymatically released glucose multiplied by 162/180 (or 0.9) divided by the weight of the as receivedsample. Fifteen laboratories that represented feed company, regulatory, research, and commercial feed testing laboratories analyzed 10 homogenous test materials representing animal feedstuffs and pet foods induplicate using the dietary starch assay. The test samples ranged from 1 to 70% in dietary starch content and included moist canned dog food, alfalfa pellets, distillers grains, ground corn grain, poultry feed, low starch horse feed, dry dog kibbles, complete dairy cattle feed, soybean meal, and corn silage.Theaverage within-laboratory repeatability SD (sr) for percentage dietary starch in the test samples was 0.49 with a range of 0.03 to 1.56, and among-laboratory repeatability SDs (sR) averaged 0.96 with a range of 0.09 to 2.69. The HorRat averaged 2.0 for all test samples and 1.9 for test samples containing greater than 2% dietary starch. The HorRat results are comparable to those found for AOAC Method 996.11, which measures starch in cereal products. It is recommended that the dietary starch method be accepted for Official First Action status.

2009 ◽  
Vol 92 (1) ◽  
pp. 42-49 ◽  
Author(s):  
Mary B Hall

Abstract Starch is a nutritionally important carbohydrate in feeds that is increasingly measured and used for formulation of animal diets. Discontinued production of the enzyme Rhozyme-S required for AOAC Method 920.40 invalidated this method for starch in animal feeds. The objective of this study was to compare methods for the determination of starch as potential candidates as a replacement method and for an AOAC collaborative study. Many starch methods are available, but they vary in accuracy, replicability, and ease of use. After assays were evaluated that differed in gelatinization method, number of reagents, and sample handling, and after assays with known methodological defects were excluded, 3 enzymaticcolorimetric assays were selected for comparison. The assays all used 2-stage, heat-stable, -amylase and amyloglucosidase hydrolyses, but they differed in the gelatinization solution (heating in water, 3-(N-morpholino) propanesulfonic acid buffer, or acetate buffer). The measured values included both starch and maltooligosaccharides. The acetate buffer-only method was performed in sealable vessels with dilution by weight; it gave greater starch values (26 percentage units of sample dry matter) in the analysis of feed/food substrates than did the other methods. This method is a viable candidate for a collaborative study.


1963 ◽  
Vol 46 (4) ◽  
pp. 603-610
Author(s):  
P Chichilo

Abstract Six samples of liming materials, including carbonates and silicates, were analyzed for silicon content by: (I) The AOAC method; (II) the AOAC method plus volatilization of SiO2 with HF; (III) the AOAC method, omitting the Na2CO3 fusion of the sample, including the HClO4 dehydration of SiO2, plus HF volatilization of SiO2; and (IV) a colorimetric method. Nine collaborators reported results by Methods I, II, and III and eleven by Method IV. Precision of the methods was good; no method was superior for all samples. Method I gave high results for most samples; the average result with Method I for a standard sample of dolomite was high, but that for a standard limestone was near the certificate value. Average results by Methods II, III, and IV for the standard samples were near certificate values. The collaborators appeared to prefer Method IV.


1974 ◽  
Vol 57 (6) ◽  
pp. 1360-1362
Author(s):  
Luis F Corominas

Abstract The present official first action method for biuret, 2.073-2.075, has been compared with a modified version (larger sample size, vacuum removal of ammonia and ammonium carbonate, and recrystallization of biuret standard) and a colorimetric method using nickel sulfate as the color complexing agent. Five samples containing from 0.4 to 0.9% biuret were collaboratively studied. In general, the modified method yielded better results, based on 515 individual results reported by 7 laboratories.


1990 ◽  
Vol 73 (1) ◽  
pp. 54-57 ◽  
Author(s):  
Kurt Kolar

Abstract A colorimetric method for the determination of hydroxyproline as a measure of collagen in meat and meat products has been collaboratively studied in 18 laboratories. The method includes hydrolysis with sulfuric acid, oxidation with chloramine- T, and formation of a reddish purple complex with 4- dimethylaminobenzaldehyde. Five frozen and 3 freeze-dried samples were tested, ranging in content from 0.11 to 0.88% and from 0.39 to 4.0% hydroxyproline, respectively. The mean values of 2 identical samples were 0.245 and 0.251 %. The average recovery from a spiked sample was 96.1 %. The hydroxyproline content of a known sample (a mixture of 2 samples in the ratio 5:2) was calculated to 1.42%, which agrees well with the analytical result, 1.40%. In comparison with other collaborative studies, based on the ISO analytical method, the repeatability and reproducibility of this method agree well with the other results. This method was accepted as an official NMKL method by all national Committees, and has been adopted official first action by AOAC as an NMKLAOAC method.


1972 ◽  
Vol 55 (3) ◽  
pp. 549-556
Author(s):  
J H Kahn ◽  
E T Blessinger

Abstract Fifteen chemists participated in a collaborative study for the quantitative pas-liquid chromatographic determination of the individual fusel alcohols and ethyl acetate in whisky. Two levels of congeners represented by 4 coded samples of whisky were analyzed by using t h e proposed method, employing a glycerol-1,2,6-hexanetriol column, and the official AOAC method, 9.063-9.065. Since isobutyl and the atnyl alcohols comprise by far the greatest part of fusel oil, their determination is of major importance to the total fusel oil content . Statistical analyses show that the proposed method is superior to the AOAC method for the determination of these alcohols, whereas the official method is superior for the determination of ethyl acetate and n-propyl alcohol. In general, collaborators employing modern instrumentation preferred the proposed method over the AOAC method. The former method also separates and permits the quantitative measurement of active amyl and isoamyl alcohols. The proposed method has been adopted as official first action as an alternative to 9.063–9.065 for the determination of higher alcohols and ethyl acetate in whisky.


1967 ◽  
Vol 50 (2) ◽  
pp. 334-338
Author(s):  
Duane H Strunk ◽  
A A Andreasen

Abstract Results are given on a collaborative study in which a zinc dibenzyldithiocarbamate (ZDBT) colorimetric method is used to measure copper in alcoholic products such as high wine, spirits, gin, whisky, brandy, rum, and wine. In this method, the sample is made ca 0.SN with sulfuric acid, and carbon tetrachloride containing 0.2% ZDBT is added. The colored copper-ZDBT complex is extracted in the carbon tetrachloride and measured at 438 mμ against a similar carbon tetrachloride extract of a blank. Data show good precision, and it is recommended that the ZDBT method be adopted as official, first action.


1972 ◽  
Vol 55 (3) ◽  
pp. 581-582
Author(s):  
Roger G Burkepile

Abstract A collaborative study of the proposed method for phosphorus in gelatin, dessert preparations, and mixes has been conducted. The present AOAC method for phosphorus in fertilizers, 2.023–2.025(a), was modified for this study. Preliminary work by the Associate Referee involving 4 phosphorus standard samples compared the proposed method with the official final action AOAC method for gelatin, 23.004. Additionally, phosphorus standard spikes in gelatin at the 1 and 10 mg P2O5, levels were determined by the proposed method. The proposed method is faster and more sensitive than the official method and is as accurate. Five collaborators and the Associate Referee analyzed 4 prepared samples containing various levels of phosphorus by the proposed method. The standard deviations varied from 0.005 for a 225 Bloom gelatin containing an average of 0.273% P2O5 to 0.016 for a strawberry-flavored commercial gelatin with added lecithin containing an average of 0.110% P2O5. The proposed method has been adopted as official first action to replace 23.004, which was repealed, official first action.


1982 ◽  
Vol 65 (5) ◽  
pp. 1095-1096
Author(s):  
Stanley M Cichowicz ◽  
Ruth Bandler ◽  
◽  
R Bandler ◽  
G Dzidowski ◽  
...  

Abstract The official AOAC method for determination of Geotrichum mold in canned fruits and vegetables (44.079) requires a series of 3 sieves, Nos. 8, 16, and 230, to separate the packing liquid from the product and the mold from the packing liquid. Although this method has been successful for whole or coarsely chopped products (e.g., green beans, potatoes, carrots, and beets), finely divided products such as fruit purees and tomato products tend to clog the sieves. A method was developed in which the product is centrifuged, diluted by volume, stained with crystal violet, and counted with the sieving steps eliminated. The proposed method was adopted official first action.


2008 ◽  
Vol 91 (4) ◽  
pp. 685-693 ◽  
Author(s):  
Anivis A Sanchez ◽  
Harold M Campbell ◽  
M S Ahmed ◽  
K Albert ◽  
C Applegate ◽  
...  

Abstract The performance characteristics of a liquid chromatographic (LC) method for the analysis of decoquinate (DEC) in supplements, premixes, and complete animal feeds at medicating and trace levels were collaboratively studied. DEC is extracted from ground feed samples with 1 calcium chloridemethanol solution using mechanical agitation for 90 min. After centrifugation for 5 min and dilution (if necessary), an aliquot of the extract is diluted with water. The diluted extracts are filtered and analyzed by reversed-phase LC with fluorescence detection. Suspect positive trace-level samples are confirmed by using an alternate excitation wavelength. Fourteen test samples of medicated feeds, supplement, and medicated premix, along with 8 test samples for trace-level analysis, were sent to 13 collaborators (one in Canada, 4 in Europe, and 8 in the United States). Test samples were analyzed as blind duplicates. Acceptable results were received from 12 laboratories for the medicated test samples and from 13 laboratories for the trace-level samples. Repeatability relative standard deviation estimates ranged from 1.3 to 5.6. Reproducibility relative standard deviations estimates ranged from 2.8 to 6.1, and HorRat values ranged from 0.22 to 0.74.


1981 ◽  
Vol 64 (3) ◽  
pp. 704-708
Author(s):  
Luis F Corominas ◽  
Víctor M Boy ◽  
Pedro Rojas

Abstract The AOAC official first action method, 2.147-2.150, for flame emission spectrophotometry (FES) determination of sodium in fertilizers was compared with the atomic absorption spectrophotometric (AAS) method and the sodium selective electrode (SSE) method. Ammonium oxalate, which was previously compared with water, H2SO4, HC1, and HNO3, was used to extract the sample for all 3 methods. Three synthetic NPK samples, 3 commercial samples (urea, normal superphosphate, and neutrophos), 1 phosphate rock, and 2 Magruder check samples were used for the study. Statistically significant differences were obtained in averages for most of the samples, but few differences were found in standard deviations. The AAS method showed the best accuracy and precision. Accuracy of the AOAC method is acceptable. The SSE method showed the highest deviations from the theoretical values. A collaborative study is recommended to compare the AOAC with the AAS method.