scholarly journals Cryptogenic Acute Ischemic Stroke: Assessment of the Performance of a New Continuous Long-Term Monitoring System in the Detection of Atrial Fibrillation

Author(s):  
Rogerio Ferreira Sampaio ◽  
Isabel Cristina Gomes ◽  
Eduardo Back Sternick
2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
P Guedeney ◽  
J Silvain ◽  
F Hidden-Lucet ◽  
C Maupain ◽  
S Dinanian ◽  
...  

Abstract Background There are only limited options for long-term cardiac monitoring devices readily available in clinical practice for outpatients. Holter monitoring devices are limited by the uncomfort of wires and patches, the small number of leads for analysis, the quality of recordings or the monitoring duration while insertable cardiac monitors are costly and exposed to potential local complication. Purpose To describe a single center experience with a novel wearable device for cardiac rhythm monitoring. Methods The Cardioskin™ system is a patch-free, wire-free, wearable device with rechargeable batteries that provides a high quality 15-lead electrocardiogram monitoring over 1 month (Figure 1). Data are sent using a mobile application downloaded in the patient smartphone to a central Corelab where they can be interpreted by an expert and/or the prescribing physician. An alarm signal is readily available within the Cardioskin™ device, to allow patients to indicate the presence of symptoms. In this single center retrospective registry, we provide a first report of the use of this novel device in real world practice, with indication and duration of cardiac monitoring left at the physicans “discretion”. Results From January 2019 to December 2019, the Cardioskin™ system was prescribed in 60 patients for an overall median duration of 26.5 (14–32) days. The mean age of the patients was 45±12.2 years and 24 (40%) were male. Indications for cardiac monitoring were post-Stroke, palpitation, syncope and cardiomyopathy assessment in 56%, 30%, 7% and 7% of the cases, respectively. A sustained (>30 seconds) supraventricular tachycardia was detected in 4 cases, including one case of atrial fibrillation, two case of atrial tachycardia and on case of junctional tachycardia. Unsustained ventricular tachycardia and atrial fibrillation burst were detected in another 2 cases (Figure 1). There was no reported case of skin irritation by the Cardioskin™ system or abrupt interruption of the monitoring by the patients. Conclusion The Cardioskin™ system is a novel, discreet and comfortable cardiac rhythm wearable long-term monitoring device which can be used in clinical practice for broad diagnostic indications. Figure 1. Cardioskin system Funding Acknowledgement Type of funding source: Public Institution(s). Main funding source(s): ACTION coeur


Stroke ◽  
2014 ◽  
Vol 45 (suppl_1) ◽  
Author(s):  
Tae-Jin Song ◽  
Jinkwon Kim ◽  
Dongbeom Song ◽  
Yong-Jae Kim ◽  
Hyo Suk Nam ◽  
...  

Background: Cerebral microbleeds (CMBs) were predictive of mortality in elderly and considered as a putative marker for risk of intracranial hemorrhage. Stroke patients with non valvular atrial fibrillation (NVAF) require anticoagulation, which increases the risk of hemorrhages. We investigated association of CMBs with the long term mortality in acute ischemic stroke patients with NVAF. Methods: During 6 years , consecutive ischemic stroke patients who had NVAF and who had undergone brain MRI with a gradient-recalled echo sequence were enrolled. Long-term mortality and causes of death were identified using data from Korean National Statistical Office. Survival analysis was performed whether the presence, number and location of CMBs were related with all causes, cardiovascular, and cerebrovascular mortality during follow-up. Results: Total 506 patients were enrolled during the study period and were followed up for median 2.5 years. CMBs were found in 30.8% of patients (156/506). Oral anticoagulation with warfarin was prescribed at discharge in 477 (82.7%) patients. During follow up, 177 (35%) patients died and cerebrovascular death was noted in 93 patients (81 ischemic stroke and 12 hemorrhagic stroke). After adjusting age, sex and significant variables in univariate analysis (p<0.1), multiple CMBs (≥5) were the independent predictor for all-cause, cardiovascular and ischemic stroke mortalities. The strictly lobar CMBs were associated with hemorrhagic stroke mortality in multivariate Cox regression analysis (HR 4.776, p=0.032) (Figure 1). Conclusions: Multiple CMBs were the independent predictor for the long term mortality in stroke patients with NVAF. Among them, patients with strictly lobar CMBs had a high risk of death due to hemorrhagic stroke. Our findings suggest that detection of CMBs in stroke patients with NVAF are of clinical relevance for predicting long term outcome and that particular concern is necessary in those with strictly lobar CMBs for their increased risk of death due to hemorrhagic stroke. Figure 1.


Sign in / Sign up

Export Citation Format

Share Document