Single-Phase Ground Fault Detection of Small Current Grounding System Base on Wavelets Analysis

Author(s):  
Huanghuang Liu ◽  
Qianjin Liu
1970 ◽  
Vol 1 (1) ◽  
Author(s):  
Yang Fan

The current distribution network single-phase ground fault detection model knowledge expression is poor, its production process only based on the normal distribution network sample data, no single-phase ground fault data, did not make full use of a prior knowledge, resulting in low detection accuracy. The automatic detection model of single-phase earth fault of new distribution network is proposed. The fault characteristic vector is taken as the input vector, and the degree of matching between the input vector and the weight vector element is introduced as the second layer. The fault vector is used as the input vector, and the fault vector is used as the input vector. Node input, the second layer of the output as the third layer of the input, the model training, the output of the results of the distribution network is a single-phase ground fault detection results. The experimental results show that the proposed model has high detection accuracy. 


2014 ◽  
Vol 492 ◽  
pp. 407-411 ◽  
Author(s):  
Yin Tao ◽  
Yu Juan

Single-phase ground fault line selection problem has never been satisfactorily resolved in small current neutral grounding system in china. According to such a situation and combining theoretical analysis and simulation research with reports published in literature, existing faulty line selection technologies are generalized, and working principles, application conditions and existing defects of these technologies are analyzed, meanwhile the feasible improvement of these technologies and the up-to-date research achievements, and deficiencies of applications in this field are summarized. Finally, the development trend of faulty line selection technology for small-current neutral grounding system is pointed out.


2014 ◽  
Vol 513-517 ◽  
pp. 3552-3555
Author(s):  
Xiang Gao ◽  
Lu Wang

For the problem of single-phase ground fault line selection of small current grounding system, in this paper, according to the wavelet theory advantage processing capabilities of transient mutation signal ,line selection criterion based on wavelet transform modulus maximum principle of singularity detection is proposed . By analyzing the single-phase ground fault waveform of small current grounding system in the neutral point not effective grounding system, steady state and transient characteristics of fault occurs is obtained, building bus with three outlets of 10KV small current grounding system simulation model by using MATLAB software, and verifying the validity though a large number of simulation experiments on the method.


Sign in / Sign up

Export Citation Format

Share Document