Impact of the round window membrane accessibility on hearing preservation in adult cochlear implantation

2017 ◽  
Vol 274 (8) ◽  
pp. 3049-3056 ◽  
Author(s):  
Marjan Mirsalehi ◽  
Saleh Mohebbi ◽  
Mahsa Ghajarzadeh ◽  
Thomas Lenarz ◽  
Omid Majdani
2020 ◽  
Vol 163 (2) ◽  
pp. 375-381
Author(s):  
Giselle L. Gotamco ◽  
Chuan-Hung Sun ◽  
Yi-Fan Chou ◽  
Chuan-Jen Hsu ◽  
Hung-Pin Wu

Objectives This study aims to compare the hearing preservation outcomes in cochlear implant surgery following slit versus full opening of the round window membrane. Setting Tertiary referral center. Study Design Comparative study. Subjects and Methods Seventy patients (mean, 26.3 years; range, 2-69 years) who underwent cochlear implantation via the round window approach were included in the study. Thirty-five subjects were prospectively enrolled for cochlear implantation via the open round window technique between August 2018 and January 2019. Thirty-five patients who underwent cochlear implantation from January 2017 to July 2018 via the slit round window opening, frequency matched by sex and age, were retrospectively enrolled. Pre- and postoperative thresholds were obtained. The percentage of hearing preservation was computed with the HEARRING Network formula and classified into complete, partial, and minimal hearing preservation. The results between the groups were compared and analyzed at 6 months postoperatively. Results The rate of complete hearing preservation in the open group was statistically significant ( P = .030) at 71.4% (n = 25) as compared with 45.7% (n = 16) in the slit group. Conclusions The widely opened round window may be an optional technique that surgeons can utilize to improve hearing preservation outcomes.


2019 ◽  
Vol 139 (7) ◽  
pp. 618-624
Author(s):  
Jeong Hun Jang ◽  
Oak-Sung Choo ◽  
Hantai Kim ◽  
Hun Yi Park ◽  
Yun-Hoon Choung

2021 ◽  
pp. 014556132110091
Author(s):  
Robin Rupp ◽  
Joachim Hornung ◽  
Matthias Balk ◽  
Matti Sievert ◽  
Sarina Müller ◽  
...  

Objective: To investigate the anatomical status of the round window niche and hearing outcome of cochlear implantation (CI) after explorative tympanotomy (ExT) with sealing of the round window membrane in patients with sudden sensorineural hearing loss at a tertiary referral medical center. Methods: Between January 1, 2007, and July 30, 2020, 1602 patients underwent CI at our department. Out of these, all patients previously treated by ExT with sealing of the round window membrane because of unilateral sudden hearing loss were included in the study. A retrospective chart review was conducted concerning method of round window membrane sealing, intraoperative findings during CI, postoperative imaging, and hearing results. Results: Twenty one patients (9 females; 8 right ears; 54.3 years [± 12.9 years]) underwent ExT with sealing of the round window membrane with subsequent CI after 26.6 months (± 32.9 mo) on average. During CI, in 76% of cases (n = 16), the round window niche was blocked by connective tissue due to the previous intervention but could be removed completely in all cases. The connective tissue itself and its removal had no detrimental effects on the round window membrane. Postoperative computed tomography scan showed no electrode dislocation. Mean postoperative word recognition score after 3 months was 57.4% (± 17.2%) and improved significantly to 73.1% (± 16.4%, P = .005) after 2 years. Conclusion: Performing CI after preceding ExT, connective tissue has to be expected blocking the round window niche. Remaining tissue can be removed safely and does not alter the round window membrane allowing for a proper electrode insertion. Short- and long-term hearing results are satisfactory. Consequently, ExT with sealing of the round window membrane in patients with sudden sensorineural hearing loss does not impede subsequent CI that can still be performed safely.


2020 ◽  
Vol 42 (3) ◽  
pp. 23-25
Author(s):  
Rabindra B Pradhananga ◽  
Bigyan R Gyawali ◽  
Pabina Rayamajhi

Introduction The round window is thought to be an ideal port for inserting electrodes during cochlear implantation. Considering its complex anatomy with an individual variation, this study aims to review the anatomy of round window based on the visibility of round window niche and round window membrane via posterior tympanotomy in pediatric and adult population who underwent cochlear implantation. MethodsThis was a retrospective observational study conducted at the Department of ENT-HNS, Institute of Medicine, Kathmandu, Nepal. Surgical notes of adult (>15 years) and pediatric cases (<15years) who underwent primary cochlear implantation from January 2015 to January 2018 were assessed for different grading of round window niche and round window membrane visibility via posterior tympanotomy. Cases with revision surgery and with incomplete documentation of intra-operative findings were excluded from the study. Statistical analysis was done using SPSS software version 25. We used Chi-square and Fisher’s exact tests to analyze the statistical association. ResultsType B round window niche (partially visible) was the most common variant seen in the pediatric group while in adults, both Type B (partially visible) and Type C (fully visible) round window niche were common. Compared to the adults, the pediatric group had good visibility of RWM. However, there was no statistical association between these observations. ConclusionThe round window has a wide range of anatomical variations with different levels of visibility of RWN and RWM in the different age groups. Although statistically insignificant, RWM visibility seemed to be better in pediatric cases compared to adults.


2017 ◽  
Vol 38 (7) ◽  
pp. 962-969 ◽  
Author(s):  
Mun Young Chang ◽  
Yoon Chan Rah ◽  
Jun Jae Choi ◽  
Shin Wook Woo ◽  
Yu-Jung Hwang ◽  
...  

2020 ◽  
Vol 26 (2) ◽  
pp. 128-135
Author(s):  
Md Zakaria Sarker ◽  
Muhammad Rafiqul Islam ◽  
Utpal Kumar Dutta ◽  
Debabrota Roy ◽  
AHM Ferdows Nur ◽  
...  

Background: Sensory neural hearing loss (SNHL) is the most common congenital sensory deficit, with an incidence of one to three per 1000 live births. Acoustic deprivation during the first 3 years of life can hinder speech and language acquisition with significant negative consequences on a child’s educational and psychosocial development. The gold standard intervention for permanent severe to profound hearing loss is cochlear implantation. Cochlear implant (CI); is a semi implantable electronic device that bypass the cochlea. Objectives: An observational study was carried out on 40 cases of pre-lingual deaf to find out the causes of pre-lingual deaf, to evaluate the preoperative procedures to set ideal criteria for pre -lingual cochlear implantation and to evaluate surgical procedure and outcome of cochlear implantations. Methods: Evaluation of the candidates included patient medical history, general health checkup, ENT examination, audiometric evaluation, CT and MRI scans, psychological profile of the candidate. A limited cortical mastoidectomy was performed. The facial recess was opened using the fossa of incudis as an initial landmark. The round window niche was visualized through the facial recess about 2 mm inferior to the stapes. A cochleostomy created by drilling over the basal turn of the cochlea anterior and inferior to the annulus of the round window membrane. The electrode array was then carefully inserted through the fenestra into the scala tympani of the cochlea. Electrophysiological testing (Neural Response Telemetry: NRT) was performed to verify the correct placement of active electrodes. Resulst: Among them 22 (55%) were male and 18 (45%) were female. Male female ratio was 1.2:1. Age distribution at implantation was 3.3±1.054(SD). Average hearing loss was 96.4±5.3(SD) dB and in aided audiogram was 63.7±4.6(SD) dB. Overall complications occurred in 10 (25%) cases. Transient facial nerve paresis in 2 (5%), injury of tympanic membrane in 1(2.5%), seroma 4(10%) and delayed otitis media in 1(2.5%) were observed. Major postoperative complications occurred in 2 cases including facial nerve palsy in 1(2.5%) case and spontaneous device failure in 1(2.5%) case. Conclusion: The result of this survey was find out the risk factor of congenital hearing loss. With a thorough preoperative evaluation, we can select proper candidates for CI which is a reliable and safe procedure with a low percentage of severe complication. Bangladesh J Otorhinolaryngol; October 2020; 26(2): 128-135


1987 ◽  
Vol 101 (2) ◽  
pp. 97-102 ◽  
Author(s):  
Burkhard K. H. Franz ◽  
Graeme M. Clark ◽  
David M. Bloom

AbstractWhen the multi-channel cochlear implant electrode is inserted into the scala tympani through the round window the operation is best performed via a posterior tympanotomy. The view of the round window membrane, however, is incomplete because of its orientation and the fact that it has a conical shape. Nevertheless, a good view along the basal turn is obtained after the antero-inferior overhang of the round window niche and the crista fenestrae have been removed. It might be damaging to drill away the postero-superior overhang as the osseous spiral lamina lies extremely close to the round window membrane.


2016 ◽  
Vol 6 (1) ◽  
pp. 1-8 ◽  
Author(s):  
Ingo Todt ◽  
Arneborg Ernst ◽  
Philipp Mittmann

Intracochlear pressure changes during the cochlear implant insertion are assumed to be an important contributor to hearing preservation. The aim was to observe intracochlear pressure changes by different round window opening sizes and different hydrophilic electrode conditions. The experiments were performed in a cochlear model with a micropressure sensor in the helicotrema area. Different artificial round window membrane and different moisturized electrode conditions were compared. A punctured round window causes a significantly higher and an indirect moisturized electrode condition a significantly lower intracochlear pressure change. The degree of round window opening and the hydrophilic character of an electrode during insertion affect the intracochlear pressure significantly in a model.


Sign in / Sign up

Export Citation Format

Share Document