Development of Methodology for Calculating Parameters of Continuous Deformation of Pipe Billet at Production of Electric-Welded Pipes of Small and Medium Diameter

Metallurgist ◽  
2021 ◽  
Author(s):  
S. V. Samusev ◽  
V. A. Fadeev
2016 ◽  
Vol 1 (6) ◽  
Author(s):  
H. K. Moffatt ◽  
Raymond E. Goldstein ◽  
Adriana I. Pesci

Author(s):  
A.A. Shpak ◽  
◽  
A.I. Kolesnik ◽  
F.A. Avakyan ◽  
V.A. Pismenskaya ◽  
...  

Introduction and purpose. Idiopathic macular hole (IMH) is an urgent medical and social problem of the population of developed countries. It is known that microinvasive 3-port vitrectomy with gas-air tamponade is a generally accepted method of surgical treatment of IMH. There is still no clear understanding of the reasons for incomplete functional success in this category of patients, despite the anatomical success.Thus, there is a need to develop and implement in clinical practice a modification of the ILM peeling technique for the treatment of small and medium-diameter of IMH, which would not be inferior in anatomical effectiveness to existing methods and would be accompanied by a less damaging effect on the structures of the retina. Material and methods. The study included 10 patients with a diagnosis of IMH, who underwent a 3-port microinvasive 25G vitrectomy with the preservation of foveal ILM. Results. The analysis of the clinical and functional results of surgical treatment of IMH with the foveal fragment left revealed the complete closure of the macular tear, the absence of gross defects of the ellipsoid zone, an increase in the values of the average visual acuity and microperimetry from the 1st month of dynamic observation. Conclusion. The proposed low-traumatic method of fovea - sparing ILM peeling provides stable anatomical and functional result, the restoration of both morphological and functional parameters, and minimizes the mechanical impact on the retina in the fovea. Key words: macular rupture, internal limiting membrane, fovea-sparing ILM peeling.


Author(s):  
Renato Macciotta ◽  
Tommaso Carlà ◽  
Michael Hendry ◽  
Trevor Evans ◽  
Tom Edwards ◽  
...  

1978 ◽  
Vol 100 (4) ◽  
pp. 360-368
Author(s):  
Y. Yazaki ◽  
S. Hashirizaki ◽  
S. Nishida ◽  
C. Urashima

Cyclic internal oil pressure fatigue tests were carried out on medium-diameter ERW pipes of API 5LX - X60 in an attempt to determine the influence of surface defects on the fatigue strength. Experimental factors investigated were the depth and location of internal surface notch in relation to the axis of pipe. The specimen was subjected to cyclic internal pressure, the cyclic rate being 0.3–0.5 Hz. During the test, Acoustic Emission (AE) techniques were applied to detect the fatigue crack initiation. Along with the aforementioned fatigue tests, pulsating tension fatigue tests were carried out on specimens with the same surface notches as the cyclic internal pressure fatigue test specimen.


1997 ◽  
Vol 475 ◽  
Author(s):  
Peter J. Bedrossian ◽  
Matthew R. Gibbons ◽  
Charles J. Cerjan

ABSTRACTPlanar, micron-scale ellipses patterned from 700Å-thick Co films exhibit nearly-complete suppression of hysteresis when magnetized in-plane along their short axes. Using a combination of Magnetic Force Microscopy and Vibrating Sample Magnetometry, we find that the suppression of hysteresis is associated with the continuous deformation of a dipole field configuration. The presence of hysteresis for in-plane, long-axis magnetization is associated with transitions between topologically inequivalent configurations.


Sign in / Sign up

Export Citation Format

Share Document