Dynamic electromagnetic force variation mechanism and energy loss of a non-contact loading device for a water-lubricated bearing

Author(s):  
Nan Wang ◽  
Zhe Yuan ◽  
Peng Wang
Entropy ◽  
2021 ◽  
Vol 23 (9) ◽  
pp. 1228
Author(s):  
Qifan Deng ◽  
Ji Pei ◽  
Wenjie Wang ◽  
Bin Lin ◽  
Chenying Zhang ◽  
...  

Impeller trimming is an economical method for broadening the range of application of a given pump, but it can destroy operational stability and efficiency. In this study, entropy production theory was utilized to analyze the variation of energy loss caused by impeller trimming based on computational fluid dynamics. Experiments and numerical simulations were conducted to investigate the energy loss and fluid-induced radial forces. The pump’s performance seriously deteriorated after impeller trimming, especially under overload conditions. Energy loss in the volute decreased after trimming under part-load conditions but increased under overload conditions, and this phenomenon made the pump head unable to be accurately predicted by empirical equations. With the help of entropy production theory, high-energy dissipation regions were mainly located in the volute discharge diffuser under overload conditions because of the flow separation and the mixing of the main flow and the stalled fluid. The increased incidence angle at the volute’s tongue after impeller trimming resulted in more serious flow separation and higher energy loss. Furthermore, the radial forces and their fluctuation amplitudes decreased under all the investigated conditions. The horizontal components of the radial forces in all cases were much higher than the vertical components.


Author(s):  
J. Silcox

In this introductory paper, my primary concern will be in identifying and outlining the various types of inelastic processes resulting from the interaction of electrons with matter. Elastic processes are understood reasonably well at the present experimental level and can be regarded as giving information on spatial arrangements. We need not consider them here. Inelastic processes do contain information of considerable value which reflect the electronic and chemical structure of the sample. In combination with the spatial resolution of the electron microscope, a unique probe of materials is finally emerging (Hillier 1943, Watanabe 1955, Castaing and Henri 1962, Crewe 1966, Wittry, Ferrier and Cosslett 1969, Isaacson and Johnson 1975, Egerton, Rossouw and Whelan 1976, Kokubo and Iwatsuki 1976, Colliex, Cosslett, Leapman and Trebbia 1977). We first review some scattering terminology by way of background and to identify some of the more interesting and significant features of energy loss electrons and then go on to discuss examples of studies of the type of phenomena encountered. Finally we will comment on some of the experimental factors encountered.


Author(s):  
P. Trebbia ◽  
P. Ballongue ◽  
C. Colliex

An effective use of electron energy loss spectroscopy for chemical characterization of selected areas in the electron microscope can only be achieved with the development of quantitative measurements capabilities.The experimental assembly, which is sketched in Fig.l, has therefore been carried out. It comprises four main elements.The analytical transmission electron microscope is a conventional microscope fitted with a Castaing and Henry dispersive unit (magnetic prism and electrostatic mirror). Recent modifications include the improvement of the vacuum in the specimen chamber (below 10-6 torr) and the adaptation of a new electrostatic mirror.The detection system, similar to the one described by Hermann et al (1), is located in a separate chamber below the fluorescent screen which visualizes the energy loss spectrum. Variable apertures select the electrons, which have lost an energy AE within an energy window smaller than 1 eV, in front of a surface barrier solid state detector RTC BPY 52 100 S.Q. The saw tooth signal delivered by a charge sensitive preamplifier (decay time of 5.10-5 S) is amplified, shaped into a gaussian profile through an active filter and counted by a single channel analyser.


Author(s):  
C. Colliex ◽  
P. Trebbia

The physical foundations for the use of electron energy loss spectroscopy towards analytical purposes, seem now rather well established and have been extensively discussed through recent publications. In this brief review we intend only to mention most recent developments in this field, which became available to our knowledge. We derive also some lines of discussion to define more clearly the limits of this analytical technique in materials science problems.The spectral information carried in both low ( 0<ΔE<100eV ) and high ( >100eV ) energy regions of the loss spectrum, is capable to provide quantitative results. Spectrometers have therefore been designed to work with all kinds of electron microscopes and to cover large energy ranges for the detection of inelastically scattered electrons (for instance the L-edge of molybdenum at 2500eV has been measured by van Zuylen with primary electrons of 80 kV). It is rather easy to fix a post-specimen magnetic optics on a STEM, but Crewe has recently underlined that great care should be devoted to optimize the collecting power and the energy resolution of the whole system.


Author(s):  
T. Oikawa ◽  
M. Inoue ◽  
T. Honda ◽  
Y. Kokubo

EELS allows us to make analysis of light elements such as hydrogen to heavy elements of microareas on the specimen. In energy loss spectra, however, elemental signals ride on a high background; therefore, the signal/background (S/B) ratio is very low in EELS. A technique which collects the center beam axial-symmetrically in the scattering angle is generally used to obtain high total intensity. However, the technique collects high background intensity together with elemental signals; therefore, the technique does not improve the S/B ratio. This report presents the experimental results of the S/B ratio measured as a function of the scattering angle and shows the possibility of the S/B ratio being improved in the high scattering angle range.Energy loss spectra have been measured using a JEM-200CX TEM with an energy analyzer ASEA3 at 200 kV.Fig.l shows a typical K-shell electron excitation edge riding on background in an energy loss spectrum.


Author(s):  
R. F. Egerton

An important parameter governing the sensitivity and accuracy of elemental analysis by electron energy-loss spectroscopy (EELS) or by X-ray emission spectroscopy is the signal/noise ratio of the characteristic signal.


Author(s):  
R.D. Leapman ◽  
K.E. Gorlen ◽  
C.R. Swyt

The determination of elemental distributions by electron energy loss spectroscopy necessitates removal of the non-characteristic spectral background from a core-edge at each point in the image. In the scanning transmission electron microscope this is made possible by computer controlled data acquisition. Data may be processed by fitting the pre-edge counts, at two or more channels, to an inverse power law, AE-r, where A and r are parameters and E is energy loss. Processing may be performed in real-time so a single number is saved at each pixel. Detailed analysis, shows that the largest contribution to noise comes from statistical error in the least squares fit to the background. If the background shape remains constant over the entire image, the signal-to-noise ratio can be improved by fitting only one parameter. Such an assumption is generally implicit in subtraction of the “reference image” in energy selected micrographs recorded in the CTEM with a Castaing-Henry spectrometer.


Author(s):  
R.D. Leapman ◽  
C.R. Swyt

The intensity of a characteristic electron energy loss spectroscopy (EELS) image does not, in general, directly reflect the elemental concentration. In fact, the raw core loss image can give a misleading impression of the elemental distribution. This is because the measured core edge signal depends on the amount of plural scattering which can vary significantly from region to region in a sample. Here, we show how the method for quantifying spectra due to Egerton et al. can be extended to maps.


Sign in / Sign up

Export Citation Format

Share Document