Fluid injection in Enhanced Geothermal Systems: a study on the detectability of self-potential effects and on their correlation with induced seismicity

Geothermics ◽  
2017 ◽  
Vol 65 ◽  
pp. 280-294 ◽  
Author(s):  
A. Troiano ◽  
M.G. Di Giuseppe ◽  
A. Monetti ◽  
D. Patella ◽  
C. Troise ◽  
...  
2015 ◽  
Vol 52 (10) ◽  
pp. 1457-1465 ◽  
Author(s):  
Jeoung Seok Yoon ◽  
Günter Zimmermann ◽  
Arno Zang ◽  
Ove Stephansson

Enhanced geothermal systems, shale gas, and geological carbon sequestration all require underground fluid injection in high-pressure conditions. Fluid injection creates fractures, induces seismicity, and has the potential to reactivate nearby faults that can generate a large magnitude earthquake. Mechanisms of fluid injection–induced seismicity and fault reactivation should be better understood to be able to mitigate larger events triggered by fluid injection. This study investigates fluid injection, induced seismicity, and triggering of fault rupture using hydromechanical-coupled discrete element models. Results show that a small amount of fluid pressure perturbation can trigger fault ruptures that are critically oriented and stressed. Induced seismicity by rock failure shows in general higher b-values (slope of magnitude–frequency relation) compared to seismicity triggered by the fault fracture slip. Numerical results closely resemble observations from geothermal and shale-gas fields and demonstrate that discrete element modeling has the potential to be applied in the field as a tool for predicting induced seismicity prior to in situ injection.


Geothermics ◽  
2007 ◽  
Vol 36 (3) ◽  
pp. 185-222 ◽  
Author(s):  
Ernest L. Majer ◽  
Roy Baria ◽  
Mitch Stark ◽  
Stephen Oates ◽  
Julian Bommer ◽  
...  

2014 ◽  
Author(s):  
Roland Gritto ◽  
◽  
Douglas Dreger ◽  
Oliver Heidbach ◽  
Lawrence Hutchings ◽  
...  

2012 ◽  
Author(s):  
Ernie Majer ◽  
James Nelson ◽  
Ann Robertson-Tait ◽  
Jean Savy ◽  
Ivan Wong

2022 ◽  
Author(s):  
Chengjun Feng ◽  
Guangliang Gao ◽  
Shihuai Zhang ◽  
Dongsheng Sun ◽  
Siyu Zhu ◽  
...  

Abstract. The Tangshan region is one of the most seismically active areas in the North China, and the 1976 M 7.8 earthquake occurred on July 28th near the Tangshan fault zone. The Matouying Enhanced Geothermal Systems (EGS) field is located ~90 km away from Tangshan City. Since the late 2020, preliminary hydraulic stimulation tests have been conducted at depths of ~3965–4000 m. Fluid injection into geothermal reservoir facilitates heat exchanger system. However, fluid injection may also induce earthquakes. In anticipation of the EGS operation at the Matouying uplift, it is essential to assess how the fault slip potential of the nearby active and quiescent faults will change in the presence of fluid injection. In this study, we first characterize the ambient stress field in the Tangshan region by performing stress tensor inversions using 98 focal mechanism data (ML ≥ 2.5). Then, we estimate the principal stress magnitudes near the Matouying EGS field by analyzing in situ stress measurements at shallow depths (~600–1000 m). According to these data, we perform a quantitative risk assessment using the Mohr-Coulomb framework in order to evaluate how the main active faults might respond to hypothetical injected-related pore pressure increases due to the upcoming EGS production. Our results mainly show that most earthquakes in the Tangshan seismic region have occurred on the faults that have relatively high fault slip potential in the present ambient stress field. At well distances of less than 15 km, the probabilistic fault slip potential on most of the boundary faults increase with continuing fluid injection over time, especially on these faults with well distances of ~6–10 km. The probabilistic fault slip potential increases linearly with the fluid injection rate. However, the FSP values decrease exponentially with increased unit permeability. The case study of the Matouying EGS field has important implications for the deep geothermal exploitation in China, especially for Gonghe EGS (in Qinghai province) and Xiong’an New Area (in Hebei province) geothermal reservoirs that are close to the Quaternary active faults. Ongoing injection operations in the regions should be conducted with these understandings in mind.


Geophysics ◽  
2011 ◽  
Vol 76 (6) ◽  
pp. WC181-WC198 ◽  
Author(s):  
Mark W. McClure ◽  
Roland N. Horne

We describe a numerical investigation of seismicity induced by injection into a single isolated fracture. Injection into a single isolated fracture is a simple analog for shear stimulation in enhanced geothermal systems (EGS) during which water is injected into fractured, low permeability rock, triggering slip on preexisting large scale fracture zones. A model was developed and used that couples (1) fluid flow, (2) rate and state friction, and (3) mechanical stress interaction between fracture elements. Based on the results of this model, we propose a mechanism to describe the process by which the stimulated region grows during shear stimulation, which we refer to as the sequential stimulation (SS) mechanism. If the SS mechanism is realistic, it would undermine assumptions that are made for the estimation of the minimum principal stress and unstimulated hydraulic diffusivity. We investigated the effect of injection pressure on induced seismicity. For injection at constant pressure, there was not a significant dependence of maximum event magnitude on injection pressure, but there were more relatively large events for higher injection pressure. Decreasing injection pressure over time significantly reduced the maximum event magnitude. Significant seismicity occurred after shut-in, which was consistent with observations from EGS stimulations. Production of fluid from the well immediately after injection inhibited shut-in seismic events. The results of the model in this study were found to be broadly consistent with results from prior work using a simpler treatment of friction that we refer to as static/dynamic. We investigated the effect of shear-induced pore volume dilation and the rate and state characteristic length scale, [Formula: see text]. Shear-induced pore dilation resulted in a larger number of lower magnitude events. A larger value of [Formula: see text] caused slip to occur aseismically.