Advantage analysis of variable-speed pumped storage units in renewable energy power grid: Mechanism of avoiding S-shaped region

Author(s):  
Chen Feng ◽  
Chaoshun Li ◽  
Li Chang ◽  
Tan Ding ◽  
Zijun Mai
2020 ◽  
pp. 0309524X2094147
Author(s):  
Sumit Sharma ◽  
Yog Raj Sood

In this article, a green microgrid is suggested which utilizes renewable energy units such as wind, solar, hydro, and biomass in conjunction with energy storage systems like batteries and the pumped storage. Different test scenarios are investigated to optimally use the power generated from the combined usage of the renewable energy units and the storage units. To judge the performance, a comparative feasibility analysis of the proposed approach is carried out to demonstrate the potential findings based on the total net present cost, levelized cost of energy, operating cost, and initial capital cost. In addition, the proposed solution may be subject to various changes in systems configuration with regard to the wind speed, solar radiation, streamflow, and the electric load; therefore, sensitivity analysis is also presented. Moreover, Indian policy interventions are considered to demonstrate the effectiveness of the proposed approach for a reduction in the overall revenue of the system.


PLoS ONE ◽  
2021 ◽  
Vol 16 (12) ◽  
pp. e0261093
Author(s):  
Wentao Huang ◽  
Jinman Yu ◽  
Zhijun Yuan ◽  
Zhongwei He ◽  
Jun He ◽  
...  

With the construction and development of ultra-high voltage (UHV) power grids, large-scale, long-distance power transmission has become common. A failure of the connecting line between the sending-end power grid and the receiving-end power grid will cause a large-scale power shortage and a frequency drop in the receiving-end power grid, which can result in the frequency collapse. Presently, under-frequency load shedding (UFLS) is adopted for solving the frequency control problem in emergency under-frequency conditions, which can easily cause large load losses. In this context, a frequency coordination optimal control strategy is proposed, which combines the mode transition of pumped storage units with UFLS to deal with emergency under-frequency problems. First, a mathematical model of the frequency dynamic response is established, which combines the mode transition of pumped storage units with UFLS based on a single-machine equivalent model. Then, an optimal model of the minimal area of the power system’s operation frequency trajectory is introduced, yielding the optimal frequency trajectory, and is used for obtaining the action frequency of the joint control strategy. A simulated annealing algorithm based on the perturbation analysis is proposed for solving the optimal model, and the optimal action frequency is obtained that satisfies the transient frequency offset safety constraint of the power system. Thus, the joint optimal control of the mode transition of the pumped storage units and UFLS is realized. Finally, the EPRI-36 bus system and China’s actual power grid are considered, for demonstrating the efficiency of the proposed strategy.


Energies ◽  
2021 ◽  
Vol 15 (1) ◽  
pp. 204
Author(s):  
Zhiwei Zhu ◽  
Xiaoqiang Tan ◽  
Xueding Lu ◽  
Dong Liu ◽  
Chaoshun Li

The doubly-fed variable speed pumped storage unit is a storage system suitable for joint operation with renewable energy sources to smooth the imbalance between renewable energy supply and electricity demand. However, its working principle and operation control are more complex than those of constant speed pumped storage. In this study, a nonlinear model of doubly-fed variable speed pumped storage units (VSPSUs) considering nonlinear characteristics of the head loss is established. The study finds that a supercritical Hopf bifurcation occurs in the system, and the area enclosed by the lower side of the bifurcation line and the coordinate axis is the stability domain of the system. The active power step perturbation from −0.3 to 0.3 will gradually reduce the area of the stability domain and narrow the adjustable range of the control parameters. In addition, the sensitivity of the model full state variables and the primary and secondary relationships to the changes of subsystem parameters is analyzed systematically using the trajectory sensitivity. It is found that there is a large difference in the sensitivity of different state variables to the parameters. The state variables are much more sensitive to the transfer coefficient of hydraulic turbine torque to guide vane opening, the unit inertia time constant, and the controller proportional gain change than other parameters, which are defined as highly sensitive parameters. The receiver response time constant and the turbine flow-to-head transfer coefficient are the corresponding low-sensitivity parameters.


2017 ◽  
Vol 2017 (13) ◽  
pp. 745-750 ◽  
Author(s):  
Zhao Guopeng ◽  
Zhao Qiang ◽  
Ren Jiyun ◽  
Song Xiaofang ◽  
Han Minxiao

2021 ◽  
Vol 252 ◽  
pp. 02022
Author(s):  
Haoyuan Li ◽  
Guanjun Li ◽  
Bo Yang ◽  
Liantao Ji

Constant speed pumped storage unit is widely used, however it cannot adjust the input power when working in the electric mode, and cannot work in the best efficiency when the head of the reservoir changes greatly. Therefore, it is necessary to study and develop the variable speed pumped storage systems. This paper has studied on variable speed operation of static frequency converter for pumped storage units. Besides, development status of variable speed pumped storage system at home and abroad is investigated. Furthermore, classification and advantages and disadvantages of variable speed pumped storage system are also introduced, mainly including two typical variable speed pumped storage systems, i.e., doubly-fed variable speed system and full power variable speed system.


Energies ◽  
2019 ◽  
Vol 12 (12) ◽  
pp. 2317
Author(s):  
Heng Yang ◽  
Ziliang Jin ◽  
Jianhua Wang ◽  
Yong Zhao ◽  
Hejia Wang ◽  
...  

As the penetration of intermittent renewable energy increases and unexpected market behaviors continue to occur, new challenges arise for system operators to ensure cost effectiveness while maintaining system reliability under uncertainties. To systematically address these uncertainties and challenges, innovative advanced methods and approaches are needed. Motivated by these, in this paper, we consider an energy integrated system with renewable energy and pumped-storage units involved. In addition, we propose a data-driven risk-averse two-stage stochastic model that considers the features of forbidden zones and dynamic ramping rate limits. This model minimizes the total cost against the worst-case distribution in the confidence set built for an unknown distribution and constructed based on data. Our numerical experiments show how pumped-storage units contribute to the system, how inclusions of the aforementioned two features improve the reliability of the system, and how our proposed data-driven model converges to a risk-neutral model with historical data.


2021 ◽  
Vol 634 (1) ◽  
pp. 012053
Author(s):  
Huan Xie ◽  
Lili Liu ◽  
Shanying Li ◽  
Hao Liang ◽  
Qibang Tan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document