Analytical investigation on behavior of three-dimensional reinforced concrete frames under thermal effect

Author(s):  
M. Vishal ◽  
K.S. Satyanarayanan ◽  
V. Thirumurugan
Buildings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 57
Author(s):  
Marco Gaetani d’Aragona ◽  
Maria Polese ◽  
Andrea Prota

Masonry-infilled reinforced concrete frames represent a very common construction typology across the Mediterranean countries. The presence of infills substantially modifies the global seismic performances of buildings in terms of strength, stiffness, and energy dissipation. Although several research studies focused on the overall performances of infilled reinforced concrete frames, the modeling of infill panels remains an open issue due to the complex interaction between the infill and the frame and the uncertainties involved in the definition of the problem. In the present paper, an existing masonry-infilled RC frame designed according to obsolete seismic codes is chosen as a case study. A refined three-dimensional finite element model is built for performing nonlinear static and time-history analyses in order to investigate some significant aspects related to the modeling of infills. In particular, it is investigated the effect of different infill constitutive models on the seismic performance of infilled RC building expressed in terms of engineering demand parameters such as interstory drift ratios and peak floor accelerations, and on the generation of damage fragility curves.


2020 ◽  
Vol 87 (1) ◽  
pp. 92-100 ◽  
Author(s):  
N.V. FEDOROVA ◽  
◽  
FAN DINH GUOK ◽  
NGUYEN THI CHANG ◽  
◽  
...  

Author(s):  
Seung-Jae Lee ◽  
Tae-Sung Eom ◽  
Eunjong Yu

AbstractThis study analytically investigated the behavior of reinforced concrete frames with masonry infills. For the analysis, VecTor2, a nonlinear finite element analysis program that implements the Modified Compression Field Theory and Disturbed Stress Field Model, was used. To account for the slip behavior at the mortar joints in the masonry element, the hyperbolic Mohr–Coulomb yield criterion, defined as a function of cohesion and friction angle, was used. The analysis results showed that the lateral resistance and failure mode of the infilled frames were significantly affected by the thickness of the masonry infill, cohesion on the mortar joint–brick interface, and poor mortar filling (or gap) on the masonry boundary under the beam. Diagonal strut actions developed along two or three load paths on the mortar infill, including the backstay actions near the tension column and push-down actions near the compression columns. Such backstay and push-down actions increased the axial and shear forces of columns, and ultimately affect the strength, ductility, and failure mode of the infilled frames.


Sign in / Sign up

Export Citation Format

Share Document