Measurement of charge transfer during bacterial adhesion to an indium tin oxide surface in a parallel plate flow chamber

1999 ◽  
Vol 38 (3) ◽  
pp. 183-189 ◽  
Author(s):  
A.T Poortinga ◽  
R Bos ◽  
H.J Busscher
2016 ◽  
Vol 62 (11) ◽  
pp. 944-952 ◽  
Author(s):  
Lotfi Mhamdi ◽  
Nejib Mhamdi ◽  
Naceur Mhamdi ◽  
Philippe Lejeune ◽  
Nicole Jaffrezic ◽  
...  

This preliminary study focused on the effect of exposure to 0.5 T static magnetic fields on Escherichia coli adhesion and orientation. We investigated the difference in bacterial adhesion on the surface of glass and indium tin oxide-coated glass when exposed to a magnetic field either perpendicular or parallel to the adhesion surface (vectors of magnetic induction are perpendicular or parallel to the adhesion surface, respectively). Control cultures were simultaneously grown under identical conditions but without exposure to the magnetic field. We observed a decrease in cell adhesion after exposure to the magnetic field. Orientation of bacteria cells was affected after exposure to a parallel magnetic field. On the other hand, no effect on the orientation of bacteria cells was observed after exposure to a perpendicular magnetic field.


Blood ◽  
2000 ◽  
Vol 95 (2) ◽  
pp. 592-601 ◽  
Author(s):  
P. Sriramarao ◽  
Richard G. DiScipio ◽  
Ronald R. Cobb ◽  
Myron Cybulsky ◽  
Greg Stachnick ◽  
...  

The ability of the 4 integrin counterligands vascular cell adhesion molecule (VCAM)-1 or mucosal addressin (MAd)CAM-1 to support eosinophil rolling or firm adhesion under conditions of physiologic flow has not been delineated. Using a parallel plate flow chamber in vitro and intravital microscopy in vivo, we demonstrate that eosinophil rolling and adhesion on VCAM-1 is mediated by both 4β1 and 4β7 integrins. Eosinophils rolled equally efficiently on both VCAM-1 2 domain and VCAM-1 7 domain, suggesting that the N-terminal 2 domains of VCAM-1 are sufficient to support eosinophil rolling under conditions of flow. Furthermore, activation of the eosinophil β1 integrin with monoclonal antibody (mAb) 8A2 resulted in both resistance to shear stress–induced detachment from VCAM-1 in vitro and in stable arrest of rolling eosinophils on interleukin (IL)-1β–stimulated venules in vivo. Eosinophils rolled less efficiently on MAdCAM-1– than on VCAM-1–coated coverslips under conditions of flow. However, eosinophils firmly adhered as efficiently to MAdCAM-1 as to VCAM-1. Overall, these results demonstrate that both VCAM-1 and MAdCAM-1 can support eosinophil firm adhesion under conditions of flow. In contrast, VCAM-1 is significantly more efficient than MAdCAM-1 in supporting eosinophil rolling under conditions of flow.


2018 ◽  
Vol 140 (6) ◽  
Author(s):  
Hamed Avari ◽  
Kem A. Rogers ◽  
Eric Savory

The parallel plate flow chamber (PPFC) has gained popularity due to its applications in fields such as biological tissue engineering. However, most of the studies using PPFC refer to theoretical relations for estimating the wall shear stress (WSS) and, hence, the accuracy of such quantifications remains elusive for anything other than steady laminar flow. In the current study, a laser Doppler velocimetry (LDV) method was used to quantify the flow in a PPFC (H = 1.8 mm × W = 17.5 mm, Dh = 3.26 mm, aspect ratio = 9.72) under steady Re = 990, laminar pulsatile (carotid Re0-mean = 282 as well as a non-zero-mean sinusoidal Re0-mean = 45 pulse) and low-Re turbulent Re = 2750 flow conditions. A mini-LDV probe was applied, and the absolute location of the LDV measuring volume with the respect to the wall was determined using a signal monitoring technique with uncertainties being around ±27 μm. The uniformity of the flow across the span of the channel, as well as the WSS assessment for all the flow conditions, was measured with the uncertainties all being less than 16%. At least two points within the viscous sublayer of the low-Re turbulent flow were measured (with the y+ for the first point < 3) and the WSS was determined using two methods with the differences between the two methods being within 5%. This paper for the first time presents the experimental determination of WSS using LDV in a small-scale PPFC under various flow conditions, the challenges associated with each condition, and a comparison between the cases. The present data will be useful for those conducting biological or numerical modeling studies using such devices.


1999 ◽  
Author(s):  
Quoc T. Le ◽  
F. Nuesch ◽  
Eric W. Forsythe ◽  
Lewis J. Rothberg ◽  
Yongli Gao

1992 ◽  
Vol 26 (6) ◽  
pp. 725-738 ◽  
Author(s):  
T. G. van Kooten ◽  
J. M. Schakenraad ◽  
H. C. Van der Mei ◽  
H. J. Busscher

Sign in / Sign up

Export Citation Format

Share Document