laser doppler
Recently Published Documents


TOTAL DOCUMENTS

6028
(FIVE YEARS 499)

H-INDEX

92
(FIVE YEARS 6)

2022 ◽  
Vol 166 ◽  
pp. 108805
Author(s):  
Botao Zhang ◽  
Shengjie Gong ◽  
Fujun Gan ◽  
Chaozhu Zhang ◽  
Hanyang Gu

2022 ◽  
Vol 12 ◽  
Author(s):  
Silvia Seoni ◽  
Simeon Beeckman ◽  
Yanlu Li ◽  
Soren Aasmul ◽  
Umberto Morbiducci ◽  
...  

Background: Laser-Doppler Vibrometry (LDV) is a laser-based technique that allows measuring the motion of moving targets with high spatial and temporal resolution. To demonstrate its use for the measurement of carotid-femoral pulse wave velocity, a prototype system was employed in a clinical feasibility study. Data were acquired for analysis without prior quality control. Real-time application, however, will require a real-time assessment of signal quality. In this study, we (1) use template matching and matrix profile for assessing the quality of these previously acquired signals; (2) analyze the nature and achievable quality of acquired signals at the carotid and femoral measuring site; (3) explore models for automated classification of signal quality.Methods: Laser-Doppler Vibrometry data were acquired in 100 subjects (50M/50F) and consisted of 4–5 sequences of 20-s recordings of skin displacement, differentiated two times to yield acceleration. Each recording consisted of data from 12 laser beams, yielding 410 carotid-femoral and 407 carotid-carotid recordings. Data quality was visually assessed on a 1–5 scale, and a subset of best quality data was used to construct an acceleration template for both measuring sites. The time-varying cross-correlation of the acceleration signals with the template was computed. A quality metric constructed on several features of this template matching was derived. Next, the matrix-profile technique was applied to identify recurring features in the measured time series and derived a similar quality metric. The statistical distribution of the metrics, and their correlates with basic clinical data were assessed. Finally, logistic-regression-based classifiers were developed and their ability to automatically classify LDV-signal quality was assessed.Results: Automated quality metrics correlated well with visual scores. Signal quality was negatively correlated with BMI for femoral recordings but not for carotid recordings. Logistic regression models based on both methods yielded an accuracy of minimally 80% for our carotid and femoral recording data, reaching 87% for the femoral data.Conclusion: Both template matching and matrix profile were found suitable methods for automated grading of LDV signal quality and were able to generate a quality metric that was on par with the signal quality assessment of the expert. The classifiers, developed with both quality metrics, showed their potential for future real-time implementation.


2022 ◽  
Author(s):  
Chongbin Xi ◽  
Qi Wang ◽  
Xiaoming Nie ◽  
Rong Huang ◽  
Zhiyi Xiang ◽  
...  
Keyword(s):  

2022 ◽  
Vol 20 (4) ◽  
pp. 33-44
Author(s):  
A. V. Frolov ◽  
Yu. I. Loktionova ◽  
E. V. Zharkikh ◽  
V. V. Sidorov ◽  
A. I. Krupatkin ◽  
...  

Introduction. Yoga breathing exercises improve the ability to significantly reduce the respiratory rate. A decrease of the minute respiration volume results in compensatory reactions of the microcirculatory bed caused by changes in the gas composition. The reaction of the regulatory mechanisms of the microvascular bed can be evaluated by the optical non-invasive laser Doppler flowmetry method. The aim of the study was to assess the tissue microcirculation parameter changes in people performing yoga breathing exercises. Materials and methods. 25 volunteers performed yoga breathing exercises at a frequency of 3 times per minute, 2 times per minute, 1.5 times per minute, 1 time per minute for 5 minutes, and free breathing for 6 minutes before and after breathing exercises. Parameters aimed to defin the reaction of skin microcirculation in different body areas were simultaneously recorded in six sites by laser Doppler flowmetry using a distributed system of wearable analyzers. The parameters of tissue microcirculation recorded by the method of laser Doppler flowmetry were: the index of microcirculation (Im), nutritive blood flow (Imn), the amplitude of myogenic (Am), neurogenic (An), endothelial (Ae), respiratory (Ar) and cardiac (Ac) regulation circuits. Results. Yoga breathing exercises led to increase of microcirculation index at all breathing frequencies. Breathing at a frequency of 1.5 and 1/minute leads to a significant increase in nutritional blood flow. Low-frequency breathing exercises lead to an increase in blood pressure at the lowest breathing rates – 1.5/minute and 1/minute. The most significant changes were achieved at the lowest respiration rates (1 and 1.5/minute), that could be associated with hypoxic-hypercapnic mechanisms. Conclusion. The absence of significant changes in microcirculation parameters after low-frequency respiration during measurements in the supraorbital arteries in both groups characterizes the work of homeostatic mechanisms for maintaining brain perfusion in stressful situations for the body (low-frequency types of respiration, hypercapnia and hypoxia). When measured in the extremities, a change in the effect of the circulatory system regulatory mechanisms was observed; along with an increase in skin perfusion and the nutritional component, it can characterize the compensatory reaction of the microcirculation to respiration change.


2022 ◽  
Vol 20 (4) ◽  
pp. 52-61
Author(s):  
E. E. Ladozhskaya-Gapeenko ◽  
K. N. Khrapov ◽  
N. N. Petrishchev ◽  
Yu. S. Polushin ◽  
I. V. Shlyk

It is believed that microcirculation dysfunction in sepsis primarily caused by damage of the endothelium by infectious agents and pro-inflammatory cytokines. Mechanisms of impaired microcirculation in the severe course of COVID-19 and sepsis likely to be similar. However, there are few reports studied microcirculation disorders in patients with COVID-19, and their results are sometimes contradictory. Objective. To assess the microcirculation of patients with severe Covid-19 and the development of bacterial sepsis using nail bed microscopy and laser Doppler flowmetry. Materials and methods. 16 intensive care unit COVID-19 patients subsequently diagnosed with bacterial sepsis were examined. Patients underwent vital capillaroscopy and an occlusive test using laser Doppler flowmetry. The average rate of capillary blood flow, the size of the perivascular zone, the density of capillaries, the presence of intravascular aggregates, the increase in the amplitude of the maximum post-occlusive blood flow and the average value of postocclusive blood flow relative to the initial one were valuated. Additionally, the level of serum proadrenomedullin was evaluated. Studies were performed on the day of admission and in dynamics. Results. By the capillaroscopy analysis, microcirculation disorders were detected in the form of a decrease in the linear speed of capillary blood flow (<400 μm/s), an extention of the perivascular zone (>100 μm), the circulation of microaggregates; the absence of postocclusive hyperemia was determined by an occlusive test. Secondary bacterial infection led to an even greater aggravation of microcirculation disorders: an increase of the perivascular zone, the progression of intravascular aggregation resulting in microthrombosis with a decrease of the density of the capillary network (according to capillaroscopy), as well as a sharp decrease of amplitude maximal increment of blood flow of post-осclusive circulation at the time of an occlusive sample. We also revealed a trend of negative correlation between the level of serum proadrenomedullin and the maximum increase in blood flow during the occlusive test. Conclusion. The secondary bacterial infection in patients with COVID-19 leads to a significant aggravation of microcirculation disorders with the development of perfusion deficiency and interstitial edema. The increased plasma proadrenomedullin level supports the concept of the significant role of endothelial dysfunction in the pathogenesis of severe COVID-10 and bacterial sepsis.


2022 ◽  
Vol 20 (8) ◽  
pp. 3111
Author(s):  
K. V. Omelyanenko ◽  
A. Yu. Gorshkov ◽  
A. A. Fedorovich ◽  
A. I. Korolev ◽  
V. A. Dadaeva ◽  
...  

Aim. To study sex characteristics of cutaneous microvascular structure and function in a cohort of healthy working-age people without cardiovascular diseases.Material and methods. The study included 35 healthy men (42±4 years) and 34 women (41 ±5 years). The cardiovascular system was assessed in all patients. The microcirculatory bed of the skin was investigated by the following non-invasive methods: 1) computerized video capillaroscopy; 2) laser Doppler flowmetry; 3) photoplethysmography.Results. According to computerized video capillaroscopy in men, compared with women, there was a smaller number of both functioning capillaries (78 vs 86 capillaries/mm2, respectively (p<0,05)) and their total number (100 vs 120 capillaries/mm2, respectively (p<0,001)). Against the background of a decrease in capillary density in men, there was a higher skin interstitial hydration — 113 vs 96 gm (p<0,005) in men than in women. At the level of precapillary arterioles, where humoral tone regulation prevails. Laser Doppler flowmetry revealed lower pulse amplitude in men than in women — 0,87 vs 1,02 pf, respectively (p<0,05), which indicates a lower arterial blood inflow to exchange microvessels. Against this background, the constrictor response of precapillary arterioles to a sympathetic nervous system stimulation in men is higher than in women — 45% vs 40%, respectively (p<0,05). At the level of large arterioles, where neural tone regulation prevails, photoplethysmography revealed lower augmentation index standardized at a heart rate in men (-4,6 vs 1,7%, respectively, p<0,05), which indicates lower rigidity of muscular vessels in men.Conclusion. In working-age healthy people, sex differences are noted at all cutaneous microvascular levels, which must be taken into account when planning studies.


Diagnostics ◽  
2022 ◽  
Vol 12 (1) ◽  
pp. 143
Author(s):  
Taipau Chia ◽  
Jian-Guo Bau ◽  
Guo-Dung Hung ◽  
Sz-Huan Tsai ◽  
Che-Ming Hu

Severe neck-shoulder pain induces functional limitations in both life and work. The purpose of this study was to determine the characteristics of shoulder microcirculation abnormality in workers. This study recruited 32 workers and patients, both n = 16. Questionnaires were administered, and Laser Doppler Flowmetry (LDF) was used to measure microcirculatory blood flow (MBF) at the myofascial trigger points (MTrPs) on the shoulders. The absolute-deviationMMBF represented the mean MBF (MMBF) variability among subjects. The differences in the life characteristics, shoulder pain level, and microcirculatory characteristics at MTrPs between the two groups were compared. It was found that shoulder pain level was significantly higher in the patient than in the control group (p < 0.001). Deviation of the MMBF value beyond the postulated “normal range” of 60–80 was significantly higher in the patient than in the control group (p < 0.001). The MMBF deviation was significantly correlated with shoulder pain level, pain duration, and the symptom effect (p < 0.01, n = 32). A normal range for the MMBF of 60–80 on the shoulder near MTrPs is hypothesized for the first time based on this study. Noninvasive LDF can be used to assess abnormality in the MBF on shoulder MTrPs at an early stage.


Measurement ◽  
2022 ◽  
pp. 110572
Author(s):  
Artem A. Eremin ◽  
Maria V. Wilde ◽  
Mikhail V. Golub ◽  
Vladimir N. Pleshkov

2022 ◽  
Author(s):  
Sadoon K. Ayed ◽  
Natiq Abbas Fadhil ◽  
Laith Jaafer Habeeb

Sign in / Sign up

Export Citation Format

Share Document