scholarly journals Characterization of laser-driven electron and photon beams using the Monte Carlo code FLUKA

2014 ◽  
Vol 32 (2) ◽  
pp. 233-241 ◽  
Author(s):  
F. Fiorini ◽  
D. Neely ◽  
R.J. Clarke ◽  
S. Green

AbstractWe present a new simulation method to predict the maximum possible yield of X-rays produced by electron beams accelerated by petawatt lasers irradiating thick solid targets. The novelty of the method lies in the simulation of the electron refiluxing inside the target implemented with the Monte Carlo code Fluka. The mechanism uses initial theoretical electron spectra, cold targets and refiluxing electrons forced to re-enter the target iteratively. Collective beam plasma effects are not implemented in the simulation. Considering the maximum X-ray yield obtained for a given target thickness and material, the relationship between the irradiated target mass thickness and the initial electron temperature is determined, as well as the effect of the refiluxing on X-ray yield. The presented study helps to understand which electron temperature should be produced in order to generate a particular X-ray beam. Several applications, including medical and security imaging, could benefit from laser generated X-ray beams, so an understanding of the material and the thickness maximizing the yields or producing particular spectral characteristics is necessary. On the other more immediate hand, if this study is experimentally reproduced at the beginning of an experiment in which there is an interest in laser-driven electron and/or photon beams, it can be used to check that the electron temperature is as expected according to the laser parameters.

1999 ◽  
Vol 09 (03n04) ◽  
pp. 135-141
Author(s):  
KÁROLY TŐKÉSI ◽  
TAKESHI MUKOYAMA

For more detailed understanding of the line shape of X-ray peaks observed with Si ( Li ) detectors, a new Monte Carlo code was developed and tested in the range of incident X-ray energy less than 5 keV. In our simulation the individual elastic and inelastic processes in the solid and the charge collection probabilities in the different region of detectors are taken into account. The results of our model calculations are compared with experimental data. In general, good agreement is found between the experimental and calculated line shapes. This fact demonstrates the validity of the present model.


2021 ◽  
Vol 503 (4) ◽  
pp. 5193-5203
Author(s):  
Alexander A Mushtukov ◽  
Valery F Suleimanov ◽  
Sergey S Tsygankov ◽  
Simon Portegies Zwart

ABSTRACT Recently, it has been discovered that the transition of X-ray pulsars to the low luminosity state ($L\lesssim 10^{35}\, {\rm erg\ \rm s^{-1}}$) is accompanied by a dramatic spectral change. That is, the typical power-law-like spectrum with high-energy cut-off transforms into a two-component structure with a possible cyclotron absorption feature on top of it. It was proposed that these spectral characteristics can be explained qualitatively by the emission of cyclotron photons in the atmosphere of the neutron star caused by collisional excitation of electrons to upper Landau levels and further Comptonization of the photons by electron gas. The electron gas are expected to be overheated in a thin top layer of the atmosphere. In this paper, we perform Monte Carlo simulations of the radiative transfer in the atmosphere of an accreting neutron star while accounting for a resonant scattering of polarized X-ray photons by thermally distributed electrons. The spectral shape is shown to be strongly polarization-dependent in soft X-rays ($\lesssim 10\, {\rm keV}$) and near the cyclotron scattering feature. The results of our numerical simulations are tested against the observational data of the X-ray pulsar A 0535+262 in the low-luminosity state. We show that the spectral shape of the pulsar can be reproduced by the proposed theoretical model. We discuss applications of the discovery to the observational studies of accreting neutron stars.


2021 ◽  
Author(s):  
Emily J. King ◽  
Natalie N. Viscariello ◽  
Larry A. DeWerd

This work seeks to develop standard X-ray beams that are matched to radiobiology X-ray irradiators. The calibration of detectors used for dose determination of these irradiators is performed with a set of standard X rays that are more heavily filtered and/or lower energy, which leads to a higher uncertainty in the dose measurement. Models of the XRad320, SARRP, and the X-ray tube at the University of Wisconsin Medical Radiation Research Center (UWMRRC) were created using the BEAMnrc user code of the EGSnrc Monte Carlo code system. These models were validated against measurements, and the resultant modeled spectra were used to determine the amount of added filtration needed to match the X-ray beams at the UWMRRC to those of the XRad320 and SARRP. The depth profiles and half-value layer (HVL) simulations performed using BEAMnrc agreed to measurements within 3% and 3.6%, respectively. A primary measurement device, a free-air chamber, was developed to measure air kerma in the medium energy range of X rays. The resultant spectra of the matched beams had HVL's that matched the HVL's of the radiobiology irradiators well within the 3% criteria recommended by the International Atomic Energy Agency (IAEA) and the average energies agreed within 2.4%. In conclusion, three standard X-ray beams were developed at the UWMRRC with spectra that more closely match the spectra of the XRad320 and SARRP radiobiology irradiators, which will aid in a more accurate dose determination during calibration of these irradiators.


2020 ◽  
Vol 493 (4) ◽  
pp. 5761-5772 ◽  
Author(s):  
Takumi Ohmura ◽  
Mami Machida ◽  
Kenji Nakamura ◽  
Yuki Kudoh ◽  
Ryoji Matsumoto

ABSTRACT We present the results of two-temperature magnetohydrodynamic simulations of the propagation of sub-relativistic jets of active galactic nuclei. The dependence of the electron and ion temperature distributions on the fraction of electron heating, fe, at the shock front is studied for fe = 0, 0.05, and 0.2. Numerical results indicate that in sub-relativistic, rarefied jets, the jet plasma crossing the terminal shock forms a hot, two-temperature plasma in which the ion temperature is higher than the electron temperature. The two-temperature plasma expands and forms a backflow referred to as a cocoon, in which the ion temperature remains higher than the electron temperature for longer than 100 Myr. Electrons in the cocoon are continuously heated by ions through Coulomb collisions, and the electron temperature thus remains at Te > 109 K in the cocoon. X-ray emissions from the cocoon are weak because the electron number density is low. Meanwhile, X-rays are emitted from the shocked intracluster medium (ICM) surrounding the cocoon. Mixing of the jet plasma and the shocked ICM through the Kelvin–Helmholtz instability at the interface enhances X-ray emissions around the contact discontinuity between the cocoon and shocked ICM.


2021 ◽  
Vol 27 (4) ◽  
pp. 279-289
Author(s):  
Elahe Sayyadi ◽  
Asghar Mesbahi ◽  
Reza Eghdam Zamiri ◽  
Farshad Seyyed Nejad

Abstract Introduction: The present study aimed to investigate the radiation protection properties of silicon-based composites doped with nano-sized Bi2O3, PbO, Sm2O3, Gd2O3, WO3, and IrO2 particles. Radiation shielding properties of Sm2O3 and IrO2 nanoparticles were investigated for the first time in the current study. Material and methods: The MCNPX (2.7.0) Monte Carlo code was utilized to calculate the linear attenuation coefficients of single and multi-nano structured composites over the X-ray energy range of 10–140 keV. Homogenous distribution of spherical nanoparticles with a diameter of 100 nm in a silicon rubber matrix was simulated. The narrow beam geometry was used to calculate the photon flux after attenuation by designed nanocomposites. Results: Based on results obtained for single nanoparticle composites, three combinations of different nano-sized fillers Sm2O3+WO3+Bi2O3, Gd2O3+WO3+Bi2O3, and Sm2O3+WO3+PbO were selected, and their shielding properties were estimated. In the energy range of 20-60 keV Sm2O3 and Gd2O3 nanoparticles, in 70-100 keV energy range WO3 and for photons energy higher than 90 keV, PbO and Bi2O3 nanoparticles showed higher attenuation. Despite its higher density, IrO2 had lower attenuation compared to other nanocomposites. The results showed that the nanocomposite containing Sm2O3, WO3, and Bi2O3 nanoparticles provided better shielding among the studied samples. Conclusions: All studied multi-nanoparticle nanocomposites provided optimum shielding properties and almost 8% higher attenuation relative to single nano-based composites over a wide range of photon energy used in diagnostic radiology. Application of these new composites is recommended in radiation protection. Further experimental studies are suggested to validate our findings.


2021 ◽  
Author(s):  
Eric Da Silva

A hydroxyaptite [HAp; Ca5(PO4)3OH] phantom material was developed with the goal of improving the calibration protocol of the 125I-induced in vivo X-ray fluorescence (IVXRF) system of bone strontium quantification with further application to other IVXRF bone metal quantification systems, particulary those associated with bone lead quantification. It was found that calcium can be prepared pure of inherent contamination from strontium (and other elements) through a hydroxide precipitation producing pure Ca(OH)2, thereby, allowing for the production of a blank phantom which has not been available previously. The pure Ca(OH)2 can then be used for the preparation of pure CaHPO4 ⋅ 2H2O. A solid state pure HAp phantom can then be prepared by reaction of Ca(OH)2 and CaHPO4 ⋅ 2H2O mixed as to produce a Ca/P mole ratio of 1.67, that in HAp and the mineral phase of bone, in the presence of a setting solution prepared as to raise the total phosphate concentration of the solution by increasing the solubility CaHPO4 ⋅ 2H2O and thereby precipitating HAp. The procedure can only be used to prepare phantoms in which doping with the analyte does not disturb the Ca/P ratio substantially. In cases in which phantoms are to be prepared with high concentrations of strontium, the cement mixture can be modified as to introduce strontium in the form of Sr(OH)2 ⋅ 8H2O as to maintain a (Ca + Sr)/P ratio of 1.67. It was found by both X-ray diffraction spectrometry and Raman spectroscopy studies that strontium substitutes for calcium as in bone when preparing phantoms by this route. The necessity for the blank bone phantoms was assessed through the first blank bone phantom measurement and Monte Carlo simulations. It was found that for the 125I-induced IVXRF system of bone strontium quantification, the source, 125I brachytherapy seeds may be contributing coherently and incoherently scattered zirconium X-rays to the measured spectra, thereby requiring the use of the blank bone phantom as a means of improving the overall quantification methodology. Monte Carlo simulations were employed to evaluate any improvement by the introduction of HAp phantoms into the coherent normalization-based calibration procedure. It was found that HAp phantoms remove the need for a coherent conversion factor (CCF) thereby potentially increasing accuracy of the quantification. Further, it was found that in order for soft tissue attenuation corrections to be possible using spectroscopic information alone, HAp along with a suitable soft tissue surrogate material need to be employed. The HAp phantom material was used for the evaluations of portable X-ray analyzer systems for their potential for IVXRF quantification of lead and strontium with a focus on a comparison between tungsten, silver and rhodium target systems. Silver and rhodium target X-ray tube systems were found to be comparable for this quantification.


10.14311/1466 ◽  
2011 ◽  
Vol 51 (6) ◽  
Author(s):  
J. Hölzl ◽  
J. Wilms ◽  
I. Kreykenbohm ◽  
Ch. Schmid ◽  
Ch. Grossberger ◽  
...  

The eROSITA instrument on board the Russian Spectrum Roentgen Gamma spacecraft, which will be launched in 2013,will conduct an all sky survey in X-rays. A main objective of the survey is to observe galaxy clusters in order to constrain cosmological parameters and to obtain further knowledge about dark matter and dark energy. For the simulation of the eROSITA survey we present a Monte-Carlo code generating a mock catalogue of galaxy clusters distributed accordingto the mass function of [1]. The simulation generates the celestial coordinates as well as the cluster mass and redshift. From these parameters, the observed intensity and angular diameter are derived. These are used to scale Chandra cluster images as input for the survey-simulation.


2020 ◽  
Vol 27 (3) ◽  
pp. 737-745
Author(s):  
Zhijun Chi ◽  
Yingchao Du ◽  
Wenhui Huang ◽  
Chuanxiang Tang

A Thomson scattering X-ray source can provide quasi-monochromatic, continuously energy-tunable, polarization-controllable and high-brightness X-rays, which makes it an excellent tool for X-ray fluorescence computed tomography (XFCT). In this paper, we examined the suppression of Compton scattering background in XFCT using the linearly polarized X-rays and the implementation feasibility of linearly polarized XFCT based on this type of light source, concerning the influence of phantom attenuation and the sampling strategy, its advantage over K-edge subtraction computed tomography (CT), the imaging time, and the potential pulse pile-up effect by Monte Carlo simulations. A fan beam and pinhole collimator geometry were adopted in the simulation and the phantom was a polymethyl methacrylate cylinder inside which were gadolinium (Gd)-loaded water solutions with Gd concentrations ranging from 0.2 to 4.0 wt%. Compared with the case of vertical polarization, Compton scattering was suppressed by about 1.6 times using horizontal polarization. An accurate image of the Gd-containing phantom was successfully reconstructed with both spatial and quantitative identification, and good linearity between the reconstructed value and the Gd concentration was verified. When the attenuation effect cannot be neglected, one full cycle (360°) sampling and the attenuation correction became necessary. Compared with the results of K-edge subtraction CT, the contrast-to-noise ratio values of XFCT were improved by 2.03 and 1.04 times at low Gd concentrations of 0.2 and 0.5 wt%, respectively. When the flux of a Thomson scattering light source reaches 1013 photons s−1, it is possible to finish the data acquisition of XFCT at the minute or second level without introducing pulse pile-up effects.


2020 ◽  
Vol 72 ◽  
pp. 80-87
Author(s):  
G.J. Bootsma ◽  
H. Nordström ◽  
M. Eriksson ◽  
D.A. Jaffray

Sign in / Sign up

Export Citation Format

Share Document