Effects of Oversaturated Cathode Humidity Conditions on the Performance Degradation of PEMFCs and Diagnostic Signals of Warburg Impedance under Low Humidity Conditions

Author(s):  
JunHwa Kwon ◽  
KwangSup Eom
Author(s):  
Kyle D. Wesson ◽  
Swen D. Ericson ◽  
Terence L. Johnson ◽  
Karl W. Shallberg ◽  
Per K. Enge ◽  
...  

Author(s):  
Edgar Ofuchi ◽  
Ana Leticia Lima Santos ◽  
Thiago Sirino ◽  
Henrique Stel ◽  
Rigoberto Morales

2021 ◽  
pp. 112911
Author(s):  
Mengqi Yin ◽  
Jinyong Hu ◽  
Mingpeng Huang ◽  
Pei Chen ◽  
Yong Zhang

Author(s):  
D Israel ◽  
S Khan ◽  
C R Warren ◽  
J J Zwiazek ◽  
T M Robson

Abstract The roles of different plasma membrane aquaporins (PIPs) in leaf-level gas exchange of Arabidopsis thaliana were examined using knockout mutants. Since multiple Arabidopsis PIPs are implicated in CO2 transport across cell membranes, we focused on identifying the effects of the knockout mutations on photosynthesis, and whether they are mediated through the control of stomatal conductance of water vapour (gs), mesophyll conductance of CO2 (gm) or both. We grew Arabidopsis plants in low and high humidity environments and found that the contribution of PIPs to gs was larger under low air humidity when the evaporative demand was high, whereas any effect of lacking PIP function was minimal under higher humidity. The pip2;4 knockout mutant had 44% higher gs than the wild type plants under low humidity, which in turn resulted in an increased net photosynthetic rate (Anet). We also observed a 23% increase in whole-plant transpiration (E) for this knockout mutant. The lack of functional AtPIP2;5 did not affect gs or E, but resulted in homeostasis of gm despite changes of humidity, indicating a possible role in regulating CO2 membrane permeability. CO2 transport measurements in yeast expressing AtPIP2;5 confirmed that this aquaporin is indeed permeable to CO2.


2021 ◽  
Vol 18 (3) ◽  
pp. 1-22
Author(s):  
Michael Stokes ◽  
David Whalley ◽  
Soner Onder

While data filter caches (DFCs) have been shown to be effective at reducing data access energy, they have not been adopted in processors due to the associated performance penalty caused by high DFC miss rates. In this article, we present a design that both decreases the DFC miss rate and completely eliminates the DFC performance penalty even for a level-one data cache (L1 DC) with a single cycle access time. First, we show that a DFC that lazily fills each word in a DFC line from an L1 DC only when the word is referenced is more energy-efficient than eagerly filling the entire DFC line. For a 512B DFC, we are able to eliminate loads of words into the DFC that are never referenced before being evicted, which occurred for about 75% of the words in 32B lines. Second, we demonstrate that a lazily word filled DFC line can effectively share and pack data words from multiple L1 DC lines to lower the DFC miss rate. For a 512B DFC, we completely avoid accessing the L1 DC for loads about 23% of the time and avoid a fully associative L1 DC access for loads 50% of the time, where the DFC only requires about 2.5% of the size of the L1 DC. Finally, we present a method that completely eliminates the DFC performance penalty by speculatively performing DFC tag checks early and only accessing DFC data when a hit is guaranteed. For a 512B DFC, we improve data access energy usage for the DTLB and L1 DC by 33% with no performance degradation.


Sign in / Sign up

Export Citation Format

Share Document