Facile one-step synthesis of highly luminescent N-doped carbon dots as an efficient fluorescent probe for chromium(vi) detection based on the inner filter effect

2018 ◽  
Vol 42 (5) ◽  
pp. 3729-3735 ◽  
Author(s):  
Haitao Wang ◽  
Shan Liu ◽  
Yisha Xie ◽  
Jingran Bi ◽  
Yao Li ◽  
...  

Label-free fluorescence assay system is designed for Cr(iv) detection.

2020 ◽  
Vol 44 (6) ◽  
pp. 2350-2356 ◽  
Author(s):  
Nan Wang ◽  
Mengke Wang ◽  
Yang Yu ◽  
Guojian Yang ◽  
Xingguang Su

A simple and sensitive sensing strategy for sialic acid activity detection on the basis of novel near-infrared B,N co-doped carbon dots was constructed.


RSC Advances ◽  
2015 ◽  
Vol 5 (115) ◽  
pp. 95054-95060 ◽  
Author(s):  
Qingyan Zhang ◽  
Caihong Zhang ◽  
Zengbo Li ◽  
Jinyin Ge ◽  
Chenzhong Li ◽  
...  

A facile, economical and green one-step hydrothermal method for N-doped CDs was presented by using citric acid as carbon source and urea as nitrogen source. The fluorescence of N-doped CDs quenched dramatically from curcumin via inner filter effect.


2018 ◽  
Vol 42 (11) ◽  
pp. 8992-8997 ◽  
Author(s):  
Yujie Ma ◽  
Yueyue Song ◽  
Yunsu Ma ◽  
Fangdi Wei ◽  
Guanhong Xu ◽  
...  

N-doped carbon dots are used as a fluorescent probe for the sensitive and facile determination of carbamazepine based on the inner filter effect.


Author(s):  
Ke Su ◽  
Guoqiang Xiang ◽  
Yunlong Zhang ◽  
Xin Wang ◽  
Linhui Wang ◽  
...  

In this study, a rapid and sensitive analytical method has been developed to detect tetracycline hydrochloride (TC) using manganese-doped carbon dots (Mn-CDs) prepared by one-step hydrothermal procedure using 1-(2-pyridinylazo)-2-naohthalenol (PAN) and MnCl2 as precursor reagents. The obtained Mn-CDs showed an ultraviolet emission at 360 nm with an excitation wavelength of 300 nm. TC has a strong characteristic absorption peak at 356 nm, which has a large spectral overlap with the emission band of the Mn-CDs. The fluorescence intensity (FI) of Mn-CDs at 360 nm is linearly quenched within the TC concentration range of 0.1-200 µM. The developed assay for the detection of TC was based on an inner filter effect (IFE) mechanism and is rapid, sensitive, and was successfully applied for the determination of TC in different poultry meat samples with satisfactory results.


2021 ◽  
Vol 112 ◽  
pp. 110743
Author(s):  
Min Yang ◽  
Yujia Yan ◽  
Enzhou Liu ◽  
Xiaoyun Hu ◽  
Hong Hao ◽  
...  

Talanta ◽  
2021 ◽  
Vol 221 ◽  
pp. 121463
Author(s):  
Xiaowei Mu ◽  
Minxing Wu ◽  
Bo Zhang ◽  
Xin Liu ◽  
Shaomei Xu ◽  
...  

Talanta ◽  
2016 ◽  
Vol 160 ◽  
pp. 268-275 ◽  
Author(s):  
Long Wang ◽  
Yidan Bi ◽  
Juan Hou ◽  
Huiyu Li ◽  
Yuan Xu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document