ON THE DESIGN OF ROBUST CONTROL SYSTEMS FOR DISTILLATION COLUMNS

1988 ◽  
Vol 68 (1) ◽  
pp. 81-98 ◽  
Author(s):  
M. NAZMUL KARIM ◽  
GORDON K.F. LEE
Proceedings ◽  
2020 ◽  
Vol 63 (1) ◽  
pp. 46
Author(s):  
Mircea Dulau ◽  
Stelian-Emilian Oltean

An important stage in robust control design is to define the desired performances of the closed loop control system using the models of the frequency sensitivity functions S. If the frequency sensitivity functions remain within the limits imposed by these models, the control performances are met. In terms of the sensitivity functions, the specifications include: shape of S over selected frequency ranges, peak magnitude of S, bandwidth frequency, and tracking error at selected frequencies. In this context, this paper presents a study of the effects of the specifications of the weighting functions on the performances of robust control systems.