scholarly journals Study on the effect of air gap on physico-chemical and performance of PVDF hollow fibre membrane

2021 ◽  
Vol 1142 (1) ◽  
pp. 012014
Author(s):  
H S Zakria ◽  
M H D Othman ◽  
R Kamaludin ◽  
A Jilani
2017 ◽  
Vol 79 (1-2) ◽  
Author(s):  
Siti Khadijah Hubadillah ◽  
Mohd Hafiz Dzarfan Othman ◽  
A. F. Ismail ◽  
Mukhlis A. Rahman ◽  
Juhana Jaafar

Ceramic hollow fibre membrane (CHFM) demonstrated superior characteristics and performance in any separation application. The only problem associated with this kind of technology is the high cost. In order to effectively fabricate and produce low cost porous CHFM, a series of CHFMs made of kaolin were fabricated via combined phase inversion and sintering technique. The CHFMs from kaolin named as kaolin hollow fibre membranes (KHFMs) were studied at different kaolin contents of 35 wt.%, 37.5 wt.% and 40 wt.% sintered at 1200ºC. The result indicated that by varying kaolin contents, different morphologies were obtained due to changes in the viscosity of ceramic suspension containing kaolin. The optimum kaolin content for KHFM was identified. It was found that KHFM prepared at 37.5 wt% has a mechanical strength and pure water flux of A and B respectively.  


2020 ◽  
Author(s):  
Jewel Das ◽  
Harish Ravishankar ◽  
Piet Lens

<p>Hydrogen sulfide (H<sub>2</sub>S) is a toxic pollutant and harmful to human health. Industries such as pulp and paper manufacturing, rayon production, natural gas extraction and refining, and crude petroleum refineries generate waste gas streams with high H<sub>2</sub>S concentrations. Both physico-chemical and biological methods are used for H<sub>2</sub>S removal from the gas stream. Biological methods offer several advantages such as environmental friendly, less expensive and require simple operation and maintenance compared to physico-chemical methods. In this study, a hydrophilic hollow fibre membrane (HFM) based bioreactor configuration has been tested for biological H<sub>2</sub>S removal. Three reactors were fabricated and operated for ~ 3 months where two reactors were used for biological conversion process and the third reactor was used for abiotic process. The effective membrane area of a HFM module used in each reactor was 0.0138 m<sup>2</sup>. The bioreactors demonstrated efficient gas-liquid mass transfer through the HFM module and achieved ~ 99% removal efficiency with an elimination capacity of ~ 17.0 g m<sup>-3</sup> h<sup>-1</sup>. The H<sub>2</sub>S flux of the bioreactor was ~ 0.20 g m<sup>-2</sup> day<sup>-1</sup> which was ~ 9 times higher than the abiotic reactor for an inlet H<sub>2</sub>S concentration of ~ 0.90 g m<sup>-3</sup>. The overall mass transfer coefficient value for the biotic process was 17.2 µm s<sup>-1</sup> which was ~ 25 times higher than the abiotic process. The bioreactors demonstrated both microbial attached growth on the membrane surface and suspended growth in the liquid phase. Microbial community analysis confirmed the presence of diverse sulfur-oxidizing bacteria at genus level including <em>Acinetobacter</em>, <em>Dechloromonas</em>, <em>Hydrogenophaga</em>, <em>Rhodopseudomonas</em> and <em>Sulfurospirillum</em>. Moreover, the enrichment of other bacterial genera such as ammonia-oxidizing (e.g. <em>Nitrosospira</em>), organic matter degrading (e.g. <em>Trichococcus</em>) and methanogenic (e.g. <em>Methanosaeta</em>) microorganisms demonstrate the diverse microbial ecology of the sludge growing in the bioreactor.</p>


Author(s):  
Yusuf Olabode Raji ◽  
Mohd Hafiz Dzarfan Othman ◽  
Nik Abdul Hadi Sapiaa Md Nordin ◽  
Mohd Ridhwan Adam ◽  
Khairul Anwar Mohd Said ◽  
...  

2021 ◽  
Vol 1142 (1) ◽  
pp. 012011
Author(s):  
Suraya Najieha Kamarudin ◽  
Mohd Riduan Jamalludin ◽  
Siti Nor Suhaida Rasman ◽  
Siti Khadijah Hubadillah ◽  
Mohd Arif Budiman Pauzan ◽  
...  

1994 ◽  
Vol 17 (10) ◽  
pp. 543-548 ◽  
Author(s):  
Y.J. Gu ◽  
P.W. Boonstra ◽  
C. Akkerman ◽  
H. Mungroop ◽  
I. Tigchelaar ◽  
...  

The contact of blood with the artificial extracorporeal circuit causes a systemic inflammatory response due to blood activation. In this study, we compared two different paediatric membrane oxygenators used for extracorporeal circulation: a hollow fibre membrane oxygenator (Dideco Masterflo D-701, n=10), and a flat sheet silicone membrane oxygenator (Avecor Kolobow 800-2A, n=10). Blood compatibility was indicated by measuring complement activation as well as leukocyte and platelet activation. In patients perfused with a flat sheet membrane oxygenator, concentrations of complement split products C3a were significantly increased 30 minutes after the start of bypass (p<0.01), whereas only a mild increase of C3a was found in patients perfused with a hollow fibre membrane oxygenator. Leukocyte and platelet counts dropped uniformly in both groups after the start of bypass mainly due to hemodilution. Activation of leukocytes and platelets identified by both plasma β-glucuronidase and β-thromboglobulin was similar in both groups. Infants perfused with a flat sheet membrane oxygenator received significantly more donor blood than those perfused with a hollow fibre oxygenator (p<0.05). These results indicate that when used during paediatric cardiopulmonary bypass, a flat sheet membrane oxygenator has a higher complement activity than a hollow fibre membrane oxygenator, which is probably due to the relatively larger blood-surface contacting area of the oxygenator.


Sign in / Sign up

Export Citation Format

Share Document