In Vivo Remodeling and Structural Characterization of Fibrin-Based Tissue-Engineered Heart Valves in the Adult Sheep Model

2009 ◽  
Vol 15 (10) ◽  
pp. 2965-2976 ◽  
Author(s):  
Thomas C. Flanagan ◽  
Jörg S. Sachweh ◽  
Julia Frese ◽  
Heike Schnöring ◽  
Nina Gronloh ◽  
...  
2010 ◽  
Vol 58 (S 01) ◽  
Author(s):  
PM Dohmen ◽  
A Lembcke ◽  
S Holinski ◽  
JP Braun ◽  
W Konertz

2010 ◽  
Vol 81 (2) ◽  
pp. 291-299 ◽  
Author(s):  
Fernanda H.G. Peroni-Okita ◽  
Renata A. Simão ◽  
Mateus B. Cardoso ◽  
Claudinéia A. Soares ◽  
Franco M. Lajolo ◽  
...  

Author(s):  
Martijn A. J. Cox ◽  
Jeroen Kortsmit ◽  
Niels J. B. Driessen ◽  
Carlijn V. C. Bouten ◽  
Frank P. T. Baaijens

Over the last few years, research interest in tissue engineering as an alternative for current treatment and replacement strategies for cardiovascular and heart valve diseases has significantly increased. In vitro mechanical conditioning is an essential tool for engineering strong implantable tissues [1]. Detailed knowledge of the mechanical properties of the native tissue as well as the properties of the developing engineered constructs is vital for a better understanding and control of the mechanical conditioning process. The nonlinear and anisotropic behavior of soft tissues puts high demands on their mechanical characterization. Current standards in mechanical testing of soft tissues include (multiaxial) tensile testing and indentation tests. Uniaxial tensile tests do not provide sufficient information for characterizing the full anisotropic material behavior, while biaxial tensile tests are difficult to perform, and boundary effects limit the test region to a small central portion of the tissue. In addition, characterization of the local tissue properties from a tensile test is non-trivial. Indentation tests may be used to overcome some of these limitations. Indentation tests are easy to perform and when indenter size is small relative to the tissue dimensions, local characterization is possible. We have demonstrated that by recording deformation gradients and indentation force during a spherical indentation test the anisotropic mechanical behavior of engineered cardiovascular constructs can be characterized [2]. In the current study this combined numerical-experimental approach is used on Tissue Engineered Heart Valves (TEHV).


Author(s):  
João S. Soares ◽  
Trung B. Le ◽  
Fotis Sotiropoulos ◽  
Michael S. Sacks

Living tissue engineered heart valves (TEHV) may circumvent ongoing problems in pediatric valve replacements, offering optimum hemodynamic performance and the potential for growth, remodeling, and self-repair [1]. TEHV have been constructed by seeding vascular-derived autologous cells onto biodegradable scaffolds and exhibited enhanced extracellular matrix (ECM) development when cultured under pulsatile flow conditions in-vitro [2]. After functioning successfully for up to 8 months in the pulmonary circulation of growing lambs, TEHV underwent extensive in vivo remodeling and structural evolution and have demonstrated the feasibility of engineering living heart valves in vitro [3]. The employment of novel cell sources, which are clinically obtainable in principle such as bone marrow-derived mesenchymal stem cells (MSCs), is key to achieve viable clinical application [4].


2014 ◽  
Vol 1 (2) ◽  
pp. 146-162 ◽  
Author(s):  
Monica Fahrenholtz ◽  
Huiwen Liu ◽  
Debra Kearney ◽  
Lalita Wadhwa ◽  
Charles Fraser ◽  
...  

2008 ◽  
Vol 08 (01) ◽  
pp. 1-15 ◽  
Author(s):  
YOS S. MORSI ◽  
CYNTHIA S. WONG

The concept of tissue-engineered heart valves offers an alternative to current heart valve replacements that is capable of addressing shortcomings such as life-long administration of anticoagulants, inadequate durability, and inability to grow. Since tissue engineering is a multifaceted area, studies conducted have focused on different aspects such as hemodynamics, cellular interactions and mechanisms, scaffold designs, and mechanical characteristics in the form of both in vitro and in vivo investigations. This review concentrates on the advancements of scaffold materials and manufacturing processes, and on cell–scaffold interactions. Aside from the commonly used materials, polyglycolic acid and polylactic acid, novel polymers such as hydrogels and trimethylene carbonate-based polymers are being developed to simulate the natural mechanical characteristics of heart valves. Electrospinning has been examined as a new manufacturing technique that has the potential to facilitate tissue formation via increased surface area. The type of cells utilized for seeding onto the scaffolds is another factor to take into consideration; currently, stem cells are of great interest because of their potential to differentiate into various types of cells. Although extensive studies have been conducted, the creation of a fully functional heart valve that is clinically applicable still requires further investigation due to the complexity and intricacies of the heart valve.


Sign in / Sign up

Export Citation Format

Share Document