scholarly journals Clinical practice and implementation of guidelines for the prevention, diagnosis and management of cardiac implantable electronic device infections: results of a worldwide survey under the auspices of the European Heart Rhythm Association

EP Europace ◽  
2019 ◽  
Vol 21 (8) ◽  
pp. 1270-1279 ◽  
Author(s):  
Vassil Traykov ◽  
Maria Grazia Bongiorni ◽  
Giuseppe Boriani ◽  
Haran Burri ◽  
Roberto Costa ◽  
...  

Abstract Aims Cardiac implantable electronic device (CIED) infection rates are increasing. Worldwide compliance and disparities to published guidelines for the prevention, diagnosis and management of these conditions are not well elucidated. The purpose of this survey, therefore, was to clarify these issues through an inquiry to arrhythmia-related associations and societies worldwide. Methods and results A questionnaire comprising 15 questions related to CIED infections was distributed among members of seven arrhythmia societies worldwide. A total of 234 centres in 62 countries reported implantation rates of which 159 (68.0%) performed more than 200 device implantations per year and 14 (6.0%) performed fewer than 50 implantations per year. The reported rates of CIED infections for 2017 were ≤2% in 78.7% of the centres, while the infection rates exceeded 5% in 7.8% of the centres. Preventive measures for CIED infection differed from published recommendations and varied among different regions mainly in terms of pocket irrigation and administering post-operative antimicrobial therapy the use of which was reported by 39.9% and 44% of the respondents, respectively. Antibacterial envelopes were used by 37.7% of the respondents in selected circumstances. In terms of pocket infection management, 62% of the respondents applied complete system removal as an initial step. Diagnostic pocket needle aspiration and pocket surgical debridement were reported by 15.8% and 11.8% of centres, respectively. Conclusion Clinical practices for prevention and management of CIED do not fully comply with current recommendations and demonstrate considerable regional disparities. Further education and programmes for improved implementation of guidelines are mandatory.

EP Europace ◽  
2019 ◽  
Vol 22 (4) ◽  
pp. 515-549 ◽  
Author(s):  
Carina Blomström-Lundqvist ◽  
Vassil Traykov ◽  
Paola Anna Erba ◽  
Haran Burri ◽  
Jens Cosedis Nielsen ◽  
...  

Abstract Pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy devices are potentially life-saving treatments for a number of cardiac conditions, but are not without risk. Most concerning is the risk of a cardiac implantable electronic device (CIED) infection, which is associated with significant morbidity, increased hospitalizations, reduced survival, and increased healthcare costs. Recommended preventive strategies such as administration of intravenous antibiotics before implantation are well recognized. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, anti-bacterial envelopes, prolonged antibiotics post-implantation, and others. Guidance on whether to use novel device alternatives expected to be less prone to infections and novel oral anticoagulants is also limited, as are definitions on minimum quality requirements for centres and operators and volumes. Moreover, an international consensus document on management of CIED infections is lacking. The recognition of these issues, the dissemination of results from important randomized trials focusing on prevention of CIED infections, and observed divergences in managing device-related infections as found in an European Heart Rhythm Association worldwide survey, provided a strong incentive for a 2019 International State-of-the-art Consensus document on risk assessment, prevention, diagnosis, and treatment of CIED infections.


EP Europace ◽  
2012 ◽  
Vol 14 (3) ◽  
pp. 423-425 ◽  
Author(s):  
G. Marinskis ◽  
L. van Erven ◽  
M. G. Bongiorni ◽  
G. Y. H. Lip ◽  
L. Pison ◽  
...  

2019 ◽  
Vol 57 (1) ◽  
pp. e1-e31 ◽  
Author(s):  
Carina Blomström-Lundqvist ◽  
Vassil Traykov ◽  
Paola Anna Erba ◽  
Haran Burri ◽  
Jens Cosedis Nielsen ◽  
...  

Abstract Pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy devices are potentially life-saving treatments for a number of cardiac conditions, but are not without risk. Most concerning is the risk of a cardiac implantable electronic device (CIED) infection, which is associated with significant morbidity, increased hospitalizations, reduced survival, and increased healthcare costs. Recommended preventive strategies such as administration of intravenous antibiotics before implantation are well recognized. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, anti-bacterial envelopes, prolonged antibiotics post-implantation, and others. Guidance on whether to use novel device alternatives expected to be less prone to infections and novel oral anticoagulants is also limited, as are definitions on minimum quality requirements for centres and operators and volumes. Moreover, an international consensus document on management of CIED infections is lacking. The recognition of these issues, the dissemination of results from important randomized trials focusing on prevention of CIED infections, and observed divergences in managing device-related infections as found in an European Heart Rhythm Association worldwide survey, provided a strong incentive for a 2019 International State-of-the-art Consensus document on risk assessment, prevention, diagnosis, and treatment of CIED infections.


2021 ◽  
pp. 1-5
Author(s):  
Melissa M. Olen ◽  
Brynn E. Dechert ◽  
Anne Foster ◽  
Ronald J. Kanter ◽  
Michael J. Silka ◽  
...  

Abstract Background: Expert guidance from scientific societies and regulatory agencies recommend a framework of principles for frequency of in-person evaluations and remote monitoring for patients with cardiac implantable electronic devices. However, there are limited data regarding adherence to recommendations among paediatric electrophysiologists, and there are no data regarding cardiac implantable electronic device-related ancillary testing. Methods: To assess current clinical practices for cardiac implantable electronic device in-person evaluation, remote monitoring, and cardiac implantable electronic device-related ancillary testing, the Paediatric and Congenital Electrophysiology Society members were surveyed. The main outcome measures were variations in frequency of in person evaluation, frequency of remote monitoring, and cardiac implantable electronic device-related ancillary testing. Results: All respondents performed in-person evaluation at least once a year, but <50% of respondents performed an in-person evaluation within 2 weeks of cardiac implantable electronic device implantation. Remote monitoring was performed every 3 months for pacemakers and implantable cardioverter defibrillators by 71 and 75% respondents, respectively. Follow-up echocardiography was performed every 2–3 years by 53% respondents for patients with >50% ventricular pacing. Majority of respondents (75%) did not perform either an exercise stress test or ambulatory Holter monitoring or chest X-ray (65%) after cardiac implantable electronic device implantation. Conclusion: This survey identified significant practice variations in cardiac implantable electronic device in- person evaluation, remote monitoring, and ancillary testing practices among paediatric electrophysiologists. Cardiac implantable electronic device management may be optimised by development of a paediatric-specific guidelines for follow-up and ancillary testing.


2016 ◽  
Vol 68 (1) ◽  
pp. 68-71 ◽  
Author(s):  
Jayaprakash Shenthar ◽  
Shomu Bohra ◽  
Vinay Jetley ◽  
Amit Vora ◽  
Yash Lokhandwala ◽  
...  

2020 ◽  
Vol 41 (21) ◽  
pp. 2012-2032 ◽  
Author(s):  
Carina Blomström-Lundqvist ◽  
Vassil Traykov ◽  
Paola Anna Erba ◽  
Haran Burri ◽  
Jens Cosedis Nielsen ◽  
...  

Abstract Pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy devices are potentially lifesaving treatments for a number of cardiac conditions but are not without risk. Most concerning is the risk of a cardiac implantable electronic device (CIED) infection, which is associated with significant morbidity, increased hospitalizations, reduced survival, and increased health care costs. Recommended preventive strategies such as administration of intravenous antibiotics before implantation are well-recognized. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, antibacterial envelopes, prolonged antibiotics post-implantation, and others. When compared with previous guidelines or consensus statements, the present consensus document gives guidance on the use of novel device alternatives, novel oral anticoagulants, antibacterial envelopes, prolonged antibiotics post-implantation, as well as definitions on minimum quality requirements for centres and operators and volumes. The recognition that an international consensus document focused on management of CIED infections is lacking, the dissemination of results from new important randomized trials focusing on prevention of CIED infections, and observed divergences in managing device-related infections as found in an European Heart Rhythm Association worldwide survey, provided a strong incentive for a Novel 2019 International State-of-the-art Consensus document on risk assessment, prevention, diagnosis, and treatment of CIED infections.


2021 ◽  
Author(s):  
Jakrin Kewcharoen ◽  
Chanavuth Kanitsoraphan ◽  
Sittinun Thangjui ◽  
Thiratest Leesutipornchai ◽  
Sakditad Saowapa ◽  
...  

2021 ◽  
pp. 102568
Author(s):  
Fatehi Elzein ◽  
Eid Alsufyani ◽  
Yahya Al Hebaishi ◽  
Mohammed Mosaad ◽  
Moayad Alqurashi ◽  
...  

2021 ◽  
pp. bjsports-2020-103724
Author(s):  
Yorck Olaf Schumacher ◽  
Montassar Tabben ◽  
Khalid Hassoun ◽  
Asmaa Al Marwani ◽  
Ibrahim Al Hussein ◽  
...  

ObjectivesThe risk of viral transmission associated with contact sports such as football (soccer) during the COVID-19 pandemic is unknown. The aim of this study was to describe the infective and immune status of professional football players, team staff and league officials over a truncated football season resumed at the height of the COVID-19 pandemic in a country with high infection rates and to investigate the clinical symptoms related to COVID-19 infection in professional football players.MethodsProspective cohort study of 1337 football players, staff and officials during a truncated football season (9 weeks) with a tailored infection control programme based on preventive measures and regular SARS-CoV-2 PCR swab testing (every 3–5 days) combined with serology testing for immunity (every 4 weeks). Clinical symptoms in positive participants were recorded using a 26-item, Likert-Scale-based scoring system.ResultsDuring the study period, 85 subjects returned positive (cycle threshold (cT) ≤30) or reactive (30<cT<40) PCR tests, of which 36 were players. The infection rate was consistent with that of the general population during the same time period. More than half of infected subjects were asymptomatic, and the remaining had only mild symptoms with no one requiring hospitalisation. Symptom severity was associated with lower cT values. Social contacts and family were the most common sources of infection, and no infection could be traced to training or matches. Of the 36 infected players, 15 presented positive serology during the study period.ConclusionFootball played outdoors involving close contact between athletes represents a limited risk for SARS-CoV-2 infection and severe illness when preventive measures are in place.