Positional Blood Pressure Change and the Risk of Hypotension During Spinal Anesthesia for Cesarean Delivery

2011 ◽  
Vol 31 (4) ◽  
pp. 230
Author(s):  
Y.T. Jeon ◽  
J.W. Hwang ◽  
M.H. Kim ◽  
A.Y. Oh ◽  
K.H. Park ◽  
...  
2010 ◽  
Vol 111 (3) ◽  
pp. 712-715 ◽  
Author(s):  
Young-Tae Jeon ◽  
Jung-Won Hwang ◽  
Mi-Hyun Kim ◽  
Ah-Young Oh ◽  
Kyo Hoon Park ◽  
...  

QJM ◽  
2021 ◽  
Vol 114 (Supplement_1) ◽  
Author(s):  
Mohamed I Shahin ◽  
Ayman M Kamaly ◽  
Mohamed Saleh ◽  
Ashraf E El-Agamy

Abstract Background Spinal anesthesia is the preferred method for elective cesarean sections (C.S.) due to considerable risks regarding airway management associated with physiological changes of pregnancy. Hypotension is reported to occur in up to 80% of spinal anesthesia cases. Many approaches have been investigated to prevent spinal hypotension, e.g., fluid loading, vasopressors, or both. Thus we compare the administration of intermittent I.V. boluses of norepinephrine and ephedrine to guard against the hypotensive effect of spinal anesthesia during cesarean delivery. Patients and Methods 120 female patients undergoing electiveC.S.were randomly divided into “group-E” for Ephedrine and “group-N” for Norepinephrine. Results Compared with ephedrine, norepinephrine maintained maternal blood pressure and uterine artery blood flow. Further, it was associated with lower numbers of hypotension and hypertension episodes and less frequency of bradycardia and tachycardia during cesarean delivery. Conclusion Norepinephrine can be used as an alternative vasopressor to maintain maternal blood pressure during spinal anesthesia for cesarean delivery, with no adverse effect on neonatal outcome.


2017 ◽  
Vol 127 (6) ◽  
pp. 934-941 ◽  
Author(s):  
Warwick D. Ngan Kee

Abstract Background Norepinephrine has been investigated as a potential alterative to phenylephrine for maintaining blood pressure during spinal anesthesia for cesarean delivery with the advantage of less depression of maternal heart rate and cardiac output. However, the relative potencies of these two vasopressors have not been fully determined in this context. Methods In a random-allocation, graded dose–response study, 180 healthy patients undergoing spinal anesthesia for elective cesarean delivery received a single bolus of norepinephrine in one of six different doses ranging from 4 to 12 µg or phenylephrine in one of six different doses ranging from 60 to 200 µg to treat the first episode of hypotension. The magnitude of response was measured as the percentage of full restoration of systolic blood pressure to the baseline value. Dose–response analysis was performed using nonlinear regression to derive four-parameter logistic dose–response curves, which were compared to determine relative potency. Results Data were analyzed for 180 patients. The estimated ED50 values (dose giving a 50% response) were norepinephrine 10 µg (95% CI, 6 to 17 µg) and phenylephrine 137 µg (95% CI, 79 to 236 µg). The estimated relative potency ratio for the two drugs was 13.1 µg (95% CI, 10.4 to 15.8 µg). Conclusions Comparative dose–response analysis was completed for norepinephrine and phenylephrine given as a bolus to treat the first episode of hypotension in patients undergoing spinal anesthesia for cesarean delivery. The estimated dose equivalent to phenylephrine 100 µg was norepinephrine 8 µg (95% CI, 6 to 10 µg). These results may be useful to inform the design of future comparative studies.


Sign in / Sign up

Export Citation Format

Share Document