Velocity and particle-flux characteristics of turbulent particle-laden jets

The velocity and flux of spherical glass beads with nominal diameters of 200, 80 and 40 μm have been obtained by phase-Doppler anemometry in a round unconfined air jet over the first 28 diameters. The jet diameter was 15 mm and the exit velocity was 13 ms -1 giving a Reynolds number of 13 000 and a timescale of 1.15 ms, which increased quadratically with axial distance: the bead inertial time constants were 298, 48 and 12 ms. The purposes of the experiments were to quantify the velocity and flux characteristics of the beads and of the gas phase in the presence of the beads as a function of bead diameter and of the mass loading in the jet nozzle. Due to the large inertia of the 200 μm beads, the mean bead velocity downstream of the exit of the jet was constant and independent of mass loading up to 0.37 and the axial root mean square (r.m.s.) bead velocity decayed by about one-fifth : at the exit of the jet, the axial r.m.s. bead velocity was higher than that of the corresponding clean jet. The mean centreline velocity of the 80 μm beads decayed to about one-half of the bead exit velocity by 28 diameters downstream and was independent of mass loading up to 0.86. The decay rate of the mean gas centreline velocity in the presence of the beads reduced as the loading increased because of momentum transfer from the discrete to the gaseous phase. The axial r.m.s. velocity of the beads was comparable to that of the gas phase and both decreased with increasing loading and the rate of spread of the half width of the jet increased with increasing loading. For the 40 μm beads, the decay rate of the mean centreline velocity of the beads decreased with increasing loading and, in contrast to the 80 μm beads, the rate of spread decreased with increasing loading up to 0.80. The axial r.m.s. velocity of the beads became largest at a position downstream of the nozzle exit, which moved downstream with increasing loading and was larger than the axial r.m.s. velocity of the clean jet, although the beads were not expected to be responsive to the frequencies of the energy-containing eddies. The bead axial r.m.s. velocity was more than twice as large as the radial r.m.s. velocity and the correlation coefficient of the cross correlation was larger than that of the clean jet. The large bead turbulence, anisotropy and strong correlation coefficient are explained by the superposition of bead trajectories from regions of different bead mean velocity and are not because of acquisition of axial turbulent motion from the gaseous phase.

1973 ◽  
Vol 72 (2) ◽  
pp. 265-271 ◽  
Author(s):  
J. H. Dussault ◽  
D. A. Fisher ◽  
J. T. Nicoloff ◽  
V. V. Row ◽  
R. Volpe

ABSTRACT In order to determine the effect of alterations in binding capacity of thyroxine binding globulin (TBG) on triiodothyronine (T3) metabolism, studies were conducted in 10 patients with idiopathically low (7 subjects) or elevated (3 subjects) TBG levels and 10 subjects given norethandrolone (7 male subjects) or oestrogen (3 female subjects). Measurements of serum thyroxine (T4) concentration, maximal T4 binding capacity, serum T3 concentration and per cent dialyzable T3 were conducted. Serum T3 was measured both by chemical and radioimmunoassay methods. In patients with idiopathically low TBG, the mean serum T4 concentration was low (2.4 μg/100 ml), the mean serum T3 level low (55 ng/100 ml), the mean per cent dialyzable T3 increased (0.52%), and the calculated free T3 concentration normal (186 pg/100 ml). In patients with idiopathically high TBG levels the mean T4 concentration was high (10.3 μg/100 ml), the mean T3 level slightly elevated (127 ng/100 ml), the% dialyzable T3 low (0.10%) and the calculated free T3 concentration low normal (123 pg/100 ml). The correlation coefficient between the per cent dialyzable T3 and maximal TBG binding capacity in the 20 subjects was 0.68, a value significant at the P < 0.01 level. Thus, alterations in binding capacity of TBG seem to influence T3 and T4 metabolism similarly; the inverse relationship between the % of dialyzable hormone and total hormone concentration tends to keep the absolue levels of free hormones stable.


Author(s):  
O-Sung Lee ◽  
Jangyun Lee ◽  
Myung Chul Lee ◽  
Hyuk-Soo Han

AbstractThe posterior tibial slope (PTS) is usually adjusted by less than 5 degrees, without considering its individual difference, during posterior cruciate-substituting (PS) total knee arthroplasty (TKA). The effect of these individual changes of PTS would be important because clinical results depending on postoperative PTS were reported conflictingly. We investigated the effect of the change in PTS on the postoperative range of motion (ROM) and clinical scores after PS TKA. We retrospectively reviewed 164 knees from 107 patients who underwent PS TKA with a 2-year follow-up. We analyzed the preoperative and postoperative PTS, ROM, visual analog scale pain scale, Western Ontario and McMaster University Index (WOMAC), Hospital for Special Surgery Knee Score, Knee Society Score, and Forgotten Joint Score (FJS). The association of the absolute change in PTS with ROM and clinical scores was analyzed using correlation analysis and multiple regression analysis. As a result, the mean PTS and mean ROM changed from 9.6 ±  3.4 and 120.1 ±  15.4 degrees preoperatively to 2.0 ±  1.3 and 128.4 ±  9.3 degrees postoperatively, and the mean PTS change was 7.6 ±  3.5 degrees. The PTS change had no statistically significant association with the postoperative ROM and clinical scoring systems, although it did have a weak positive correlation with WOMAC function, No 10 (difficulty in rising from sitting) (correlation coefficient = 0.342, p = 0.041), and moderate positive correlation with the FJS, No. 6 (awareness when climbing stairs) (correlation coefficient = 0.470, p = 0.001). The authors concluded that the amount of change in PTS did not affect the postoperative ROM and clinical scores, although proximal tibial resection with a constant target of PTS resulted in individually different changes in the PTS after PS TKA,


Author(s):  
Yan Chen ◽  
Ward Whitt

In order to understand queueing performance given only partial information about the model, we propose determining intervals of likely values of performance measures given that limited information. We illustrate this approach for the mean steady-state waiting time in the $GI/GI/K$ queue. We start by specifying the first two moments of the interarrival-time and service-time distributions, and then consider additional information about these underlying distributions, in particular, a third moment and a Laplace transform value. As a theoretical basis, we apply extremal models yielding tight upper and lower bounds on the asymptotic decay rate of the steady-state waiting-time tail probability. We illustrate by constructing the theoretically justified intervals of values for the decay rate and the associated heuristically determined interval of values for the mean waiting times. Without extra information, the extremal models involve two-point distributions, which yield a wide range for the mean. Adding constraints on the third moment and a transform value produces three-point extremal distributions, which significantly reduce the range, producing practical levels of accuracy.


1990 ◽  
Vol 175 (5) ◽  
pp. 467-471 ◽  
Author(s):  
I.V. Koptyug ◽  
N.N. Lukzen ◽  
E.G. Bagryanskaya ◽  
A.B. Doctorov
Keyword(s):  

Author(s):  
M. A. R. Sharif ◽  
M. A. Gadalla

Abstract Isothermal turbulent mixing of an axisymmetric primary air jet with a low velocity annular secondary air stream inside a constant diameter cylindrical enclosure is predicted. The flow domain from the inlet to the fully developed downstream locations is considered. The predicted flow field properties include the mean velocity and pressure and the Reynolds stresses. Different velocity and diameter ratios between the primary and the secondary jets have been investigated to characterize the flow in terms of these parameters. A bounded stream-wise differencing scheme is used to minimize numerical diffusion and oscillation errors. Predictions are compared with available experimental data to back up numerical findings.


2016 ◽  
Vol 8 (36) ◽  
pp. 6607-6615 ◽  
Author(s):  
Stamatios Giannoukos ◽  
Boris Brkić ◽  
Stephen Taylor

A compact portable membrane inlet mass spectrometer (MIMS) has been used for the first time to detect and monitor, both qualitatively and quantitatively, volatile chlorinated hydrocarbons in the gaseous phase.


2011 ◽  
Vol 71-78 ◽  
pp. 2679-2682
Author(s):  
Xiu Hua Zhu ◽  
Song Tao Qin ◽  
Qian Xu ◽  
Yu Wen Ni ◽  
Ji Ping Chen ◽  
...  

Ambient air of Dalian was sampled with active high-volume air samplers in early spring time. The concentrations and the congeners between gas phase and particulate phase of polychlorinated dibenzo-p-dioxins and dibenzofurans(PCDD/Fs) in the air were measured. Samples analysis results showed that the concentration of PCDD/Fs in particulate phase was higher than that in gas phase. The ratio of PCDD to PCDF in gaseous phase and particulate phase was lower than 0.4. The main sources of atmospheric PCDD/Fs in Dalian early spring season were coal-related source. The total I-TEQ in gaseous phase and particulate phase was 30.3 and 143.6 fg m-3, respectively. The I-TEQ of Dalian early spring atmosphere was lower than international standard, the atmospheric quality in Dalian was better.


2016 ◽  
Vol 71 (1) ◽  
pp. 77-79 ◽  
Author(s):  
Eugen Weisheim ◽  
Hans-Georg Stammler ◽  
Norbert W. Mitzel

AbstractThe crystal structure and an improved synthesis of 1,3,5-trisilacyclohexane are reported. The solid state structure is compared with the reported structure determined in the gas phase by gas electron diffraction (GED). 1,3,5-Trisilacyclohexane adopts a chair conformation in the solid state. The Si–C bond lengths as well as all angles of 1,3,5-trisilacyclohexane in the solid state have similar dimensions compared to the structure in the gaseous phase.


2017 ◽  
Vol 27 (3) ◽  
pp. 251-256
Author(s):  
Summer Van Arsdale ◽  
Sarah E. Yost ◽  
Chiu-Hsieh Hsu ◽  
Mary Meer ◽  
Shari Schoentag ◽  
...  

Objective: Pyridoxine is 1 of 8 B vitamins that assist in a variety of essential functions including immune functions. The purpose of this study was to assess the risk factors associated with low pyridoxine levels in solid organ transplantation recipients. Design: The study cohort was divided into 2 groups: (a) patients with normal pyridoxine levels or (b) patients with low pyridoxine levels. Dietary evaluation and clinical characteristics of all patients, rejection episodes, and immunosuppression were collected. Simple descriptive statistics were used to analyze the overall cohort. Results: Of the 48 patients, 29 (60%) in the study cohort were identified to have low pyridoxine levels. The mean interval between transplantation and pyridoxine level check was 910 days (standard deviation [SD] 456). The mean weight at the time of dietary consultation was 80 kg (SD 20.7). More patients in the deficient group received thymoglobulin for rejection treatment (56% vs 0%; P = .01) and were thymoglobulin recipients (78% vs 10%; odds ratio [OR] = 31.5; 95% confidence interval [CI], 2.35-422.30; P < .01). A strong correlation was identified between thymoglobulin treatment for induction and a low level of pyridoxine (correlation coefficient R = 0.6, P = .004) and between thymoglobulin treatment for rejection and a low pyridoxine level (correlation coefficient R = 0.5, P = .05). Based on multivariate logistic regression analysis, only thymoglobulin treatment (induction or rejection treatment) was significantly associated with low pyridoxine levels (OR = 19.5, 95% CI, 1.01-375.24; P < .05). Conclusions: Low levels of pyridoxine appear to be relatively common, and thymoglobulin treatments are associated with low pyridoxine levels. Prospective studies are needed to confirm and valuate the significance of these findings.


Author(s):  
Abdullah F. Serheed ◽  
Haider T. Hussein

Afield experiment was carried out during the spring and autumn seasons of 2016 and 2017 in AL- Musaib city / 40 km north of Babylon Provence. Two hybrids of sunflower( shamus, French hybrid (Euroflor) were used to evaluate the performance of the two cultivars at both growing seasons as well as knowledge of genetic behavior by studying the genetic and phenotypic variations, heritability percent, genetic and phenotypic coefficient, stability and persistence of the two cultivars .The results showed significant differences of the studied traits, as the genetic genotype (Shamus) most of the characteristics, especially in yield for two seasons.The genetic variance was higher than the environmental variance for the two seasons indicating that the two cultivars followed the same behavior. The heritability percent the dominant sense was high for most of the traits. The genetic and phenotypic variations between the mean and the high were different for the two seasons, the correlation coefficient was significant, for both cultivars, indicating the appropriateness of the two genotypes for the country's environmental conditions.


Sign in / Sign up

Export Citation Format

Share Document