Synthesis of a low-sensitivity multiloop feedback active RC filter

1974 ◽  
Vol 21 (2) ◽  
pp. 252-259 ◽  
Author(s):  
K. Laker ◽  
M. Ghausi
1970 ◽  
Vol 58 (5) ◽  
pp. 824-825
Author(s):  
P.R. Geffe ◽  
M.A. Soderstrand ◽  
S.K. Mitra

1969 ◽  
Vol 57 (12) ◽  
pp. 2175-2176 ◽  
Author(s):  
M.A. Soderstrand ◽  
S.K. Mitra

1972 ◽  
Vol 8 (12) ◽  
pp. 303 ◽  
Author(s):  
M.S. Abougabal ◽  
B.B. Bhattacharyya

Author(s):  
Murray Vernon King ◽  
Donald F. Parsons

Effective application of the high-voltage electron microscope to a wide variety of biological studies has been restricted by the radiation sensitivity of biological systems. The problem of radiation damage has been recognized as a serious factor influencing the amount of information attainable from biological specimens in electron microscopy at conventional voltages around 100 kV. The problem proves to be even more severe at higher voltages around 1 MV. In this range, the problem is the relatively low sensitivity of the existing recording media, which entails inordinately long exposures that give rise to severe radiation damage. This low sensitivity arises from the small linear energy transfer for fast electrons. Few developable grains are created in the emulsion per electron, while most of the energy of the electrons is wasted in the film base.


Author(s):  
James F. Mancuso ◽  
Leo A. Fama ◽  
William B. Maxwell ◽  
Jerry L. Lehman ◽  
Hasso Weiland ◽  
...  

Micro-diffraction based crystallography is essential to the design and development of many classes of ‘crafted materials’. Although the scanning electron microscope can provide crystallographic information with high spatial resolution, its current utility is severely limited by the low sensitivity of existing diffraction techniques (ref: Dingley). Previously, Joy showed that energy filtering increased contrast and pattern visibility in electron channelling. This present paper discribes the effect of energy filtering on EBSP sensitivity and backscattered SEM imaging.The EBSP detector consisted of an electron energy filter, a microchannel plate detector, a phosphor screen, optical coupler, and a slow scan CCD camera. The electrostatic energy filter used in this experiment was constructed as a cone with 5 coaxial electrodes. The angular field-of-view of the filter was approximately 38°. The microchannel plate, which was the initial sensing component, had high gain and had 50% to 80% detection efficiency for the low energy electrons that passed through the retarding field filter.


1996 ◽  
Vol 5 (1) ◽  
pp. 90-96 ◽  
Author(s):  
Frank E. Musiek ◽  
Cynthia A. McCormick ◽  
Raymond M. Hurley

We performed a retrospective study of 26 patients with acoustic tumors and 26 patients with otologically diagnosed cochlear pathology to determine the sensitivity (hit rate), specificity (false-alarm rate), and efficiency of six auditory brainstem response indices. In addition, a utility value was determined for each of these six indices. The I–V interwave interval, the interaural latency difference, and the absolute latency of wave V provided the highest hit rates, the best A’ values and good utility. The V/I amplitude ratio index provided high specificity but low sensitivity scores. In regard to sensitivity and specificity, using the combination of two indices provided little overall improvement over the best one-index measures.


1989 ◽  
Vol 28 (06) ◽  
pp. 234-242 ◽  
Author(s):  
U. Sechtem ◽  
Sabine Langkamp ◽  
M. Jungehülsing ◽  
H. H. Hilger ◽  
H. Schicha ◽  
...  

Fortyfour patients with recent cardiac catheterization because of recurrent chest pain after coronary artery bypass surgery were studied by magnetic resonance imaging to evaluate graft patency. To assess the efficacy of this non-invasive method 92 coronary artery bypass grafts were examined by the spin-echo technique. ECG-gated transversal sections were acquired between the diaphragm and the aortic arch. The specificity of magnetic resonance imaging was 83% (48/58) for patent grafts. However, the sensitivity in the detection of occluded bypasses was only 56% (19/34). Despite the good specificity, clinical applications of this method are limited because of its low sensitivity.


Sign in / Sign up

Export Citation Format

Share Document